Development and validation of an optimal GATE model for proton pencil-beam scanning delivery

被引:2
作者
Asadi, Ali [1 ]
Akhavanallaf, Azadeh [2 ]
Hosseini, Seyed Abolfazl [1 ]
Vosoughi, Naser [1 ]
Zaidi, Habib [2 ,3 ,4 ,5 ,6 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[2] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Geneva, Neuroctr, Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[5] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[6] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2023年 / 33卷 / 04期
基金
瑞士国家科学基金会;
关键词
Proton therapy; Monte Carlo simulation; active scanning; AAPM TG-119; prostate; MONTE-CARLO SIMULATIONS; CARBON-ION THERAPY; DOSE-CALCULATION; OPTIMIZATION; CODE; DISTRIBUTIONS; PARAMETERS; EQUIVALENT; PLATFORM; TOPAS;
D O I
10.1016/j.zemedi.2022.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To develop and validate a versatile Monte Carlo (MC)-based dose calculation engine to support MC-based dose verification of treatment planning systems (TPSs) and quality assurance (QA) workflows in proton therapy. Methods: The GATE MC toolkit was used to simulate a fixed horizontal active scan-based proton beam delivery (SIEMENS IONTRIS). Within the nozzle, two primary and secondary dose monitors have been designed to enable the comparison of the accuracy of dose estimation from MC simulations with respect to physical QA measurements. The developed beam model was validated against a series of commissioning measurements using pinpoint chambers and 2D array ionization chambers (IC) in terms of lateral profiles and depth dose distributions. Furthermore, beam delivery module and treatment planning has been validated against the literature deploying various clinical test cases of the AAPM TG-119 (c-shape phantom) and a prostate patient. Results: MC simulations showed excellent agreement with measurements in the lateral depth-dose parameters and spread-out Bragg peak (SOBP) characteristics within a maximum relative error of 0.95 mm in range, 1.83% in entrance to peak ratio, 0.27% in mean point-to-point dose difference, and 0.32% in peak location. The mean relative absolute difference between MC simulations and measurements in terms of absorbed dose in the SOBP region was 0.93% +/- 0.88%. Clinical phantom studies showed a good agreement compared to research TPS (relative error for TG-119 planning target volume PTV-D95 = 1.8%; and for prostate PTV-D95 = -0.6%). Conclusion: We successfully developed a MC model for the pencil beam scanning system, which appears reliable for dose verification of the TPS in combination with QA information, prior to patient treatment.
引用
收藏
页码:591 / 600
页数:10
相关论文
共 50 条
  • [41] Proton FLASH: passive scattering or pencil beam scanning?
    Zhang, Guoliang
    Wang, Junliang
    Wang, Yuenan
    Peng, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)
  • [42] Pitfalls in the beam modelling process of Monte Carlo calculations for proton pencil beam scanning
    Winterhalter, Carla
    Aitkenhead, Adam
    Oxley, David
    Richardson, Jenny
    Weber, Damien C.
    MacKay, Ranald, I
    Lomax, Antony J.
    Safai, Sairos
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107)
  • [43] Technical note: Delivery benefit and dosimetric implication of synchrotron-based proton pencil beam scanning using continuous scanning mode
    Liang, Xiaoying
    Beltran, Chris J.
    Liu, Chunbo
    Shen, Jiajian
    Li, Heng
    Furutani, Keith M.
    MEDICAL PHYSICS, 2023, 50 (08) : 5252 - 5261
  • [44] Validation of automated complex head and neck treatment planning with pencil beam scanning proton therapy
    Hedrick, Samantha Grace
    Petro, Scott
    Ward, Alex
    Morris, Bart
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):
  • [45] Evaluation of monte carlo to support commissioning of the treatment planning system of new pencil beam scanning proton therapy facilities
    Botnariuc, D.
    Court, S.
    Lourenco, A.
    Gosling, A.
    Royle, G.
    Hussein, M.
    Rompokos, V
    Veiga, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04)
  • [46] Commissioning dose computation model for proton source in pencil beam scanning therapy by convolution neural networks
    Liu, Yaoying
    Shang, Xuying
    Zhao, Wei
    Li, Nan
    Qu, Baolin
    Zou, Yue
    Le, Xiaoyun
    Zhang, Gaolong
    Xu, Shouping
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (15)
  • [47] A Simple Approach for Experimental Characterization and Validation of Proton Pencil Beam Profiles
    Stasica, Paulina
    Baran, Jakub
    Granja, Carlos
    Krah, Nils
    Korcyl, Grzegorz
    Oancea, Cristina
    Pawlik-Niedzwiecka, Monika
    Niedzwiecki, Szymon
    Rydygier, Marzena
    Schiavi, Angelo
    Rucinski, Antoni
    Gajewski, Jan
    FRONTIERS IN PHYSICS, 2020, 8
  • [48] Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy
    Fracchiolla, Francesco
    Engwall, Erik
    Janson, Martin
    Tamm, Fredrik
    Lorentini, Stefano
    Fellin, Francesco
    Bertolini, Mattia
    Algranati, Carlo
    Righetto, Roberto
    Farace, Paolo
    Amichetti, Maurizio
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 226 - 234
  • [49] Stochastic model for predicting the temporal structure of the plan delivery in a synchrotron-based pencil beam scanning proton therapy system
    Burguete, J.
    Garcia-Cardosa, M.
    Antolin, E.
    Aguilar, B.
    Azcona, J. D.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [50] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472