Development and validation of an optimal GATE model for proton pencil-beam scanning delivery

被引:2
|
作者
Asadi, Ali [1 ]
Akhavanallaf, Azadeh [2 ]
Hosseini, Seyed Abolfazl [1 ]
Vosoughi, Naser [1 ]
Zaidi, Habib [2 ,3 ,4 ,5 ,6 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[2] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Geneva, Neuroctr, Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[5] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[6] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2023年 / 33卷 / 04期
基金
瑞士国家科学基金会;
关键词
Proton therapy; Monte Carlo simulation; active scanning; AAPM TG-119; prostate; MONTE-CARLO SIMULATIONS; CARBON-ION THERAPY; DOSE-CALCULATION; OPTIMIZATION; CODE; DISTRIBUTIONS; PARAMETERS; EQUIVALENT; PLATFORM; TOPAS;
D O I
10.1016/j.zemedi.2022.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To develop and validate a versatile Monte Carlo (MC)-based dose calculation engine to support MC-based dose verification of treatment planning systems (TPSs) and quality assurance (QA) workflows in proton therapy. Methods: The GATE MC toolkit was used to simulate a fixed horizontal active scan-based proton beam delivery (SIEMENS IONTRIS). Within the nozzle, two primary and secondary dose monitors have been designed to enable the comparison of the accuracy of dose estimation from MC simulations with respect to physical QA measurements. The developed beam model was validated against a series of commissioning measurements using pinpoint chambers and 2D array ionization chambers (IC) in terms of lateral profiles and depth dose distributions. Furthermore, beam delivery module and treatment planning has been validated against the literature deploying various clinical test cases of the AAPM TG-119 (c-shape phantom) and a prostate patient. Results: MC simulations showed excellent agreement with measurements in the lateral depth-dose parameters and spread-out Bragg peak (SOBP) characteristics within a maximum relative error of 0.95 mm in range, 1.83% in entrance to peak ratio, 0.27% in mean point-to-point dose difference, and 0.32% in peak location. The mean relative absolute difference between MC simulations and measurements in terms of absorbed dose in the SOBP region was 0.93% +/- 0.88%. Clinical phantom studies showed a good agreement compared to research TPS (relative error for TG-119 planning target volume PTV-D95 = 1.8%; and for prostate PTV-D95 = -0.6%). Conclusion: We successfully developed a MC model for the pencil beam scanning system, which appears reliable for dose verification of the TPS in combination with QA information, prior to patient treatment.
引用
收藏
页码:591 / 600
页数:10
相关论文
共 50 条
  • [21] Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
    Egashira, Y.
    Nishio, T.
    Hotta, K.
    Kohno, R.
    Uesaka, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04): : 1169 - 1184
  • [22] Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy
    Huang, Sheng
    Kang, Minglei
    Souris, Kevin
    Ainsley, Christopher
    Solberg, Timothy D.
    McDonough, James E.
    Simone, Charles B.
    Lin, Liyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 558 - 572
  • [23] Development of a Daily-Treatment Beam-Monitoring System Based Gafchromic EBT3 Film for Pencil-Beam Scanning Proton Therapy
    Seonghoon Jeong
    Myonggeun Yoon
    Kwangzoo Chung
    Journal of the Korean Physical Society, 2020, 76 : 769 - 773
  • [24] Development of a Daily-Treatment Beam-Monitoring System Based Gafchromic EBT3 Film for Pencil-Beam Scanning Proton Therapy
    Jeong, Seonghoon
    Yoon, Myonggeun
    Chung, Kwangzoo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (08) : 769 - 773
  • [25] Proton pencil-beam scanning radiotherapy in the treatment of nasopharyngeal cancer: dosimetric parameters and 2-year results
    Kubes, Jiri
    Vondracek, Vladimir
    Andrlik, Michal
    Navratil, Matej
    Slavikova, Silvia
    Vitek, Pavel
    Dedeckova, Katerina
    Prausova, Jana
    Ondrova, Barbora
    Rotnaglova, Eliska
    Lukes, Petr
    Patzelt, Matej
    Grebenyuk, Alexander
    Rosina, Jozef
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (03) : 763 - 769
  • [26] Proton pencil-beam scanning radiotherapy in the treatment of nasopharyngeal cancer: dosimetric parameters and 2-year results
    Kubeš Jiří
    Vondráček Vladimír
    Andrlik Michal
    Navrátil Matěj
    Sláviková Silvia
    Vítek Pavel
    Dědečková Kateřina
    Prausová Jana
    Ondrová Barbora
    Rotnáglová Eliška
    Lukeš Petr
    Patzelt Matěj
    Grebenyuk Alexander
    Rosina Jozef
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 763 - 769
  • [27] The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy
    Tsai, Pingfang
    Tseng, Yu-Lun
    Shen, Brian
    Ackerman, Christopher
    Zhai, Huifang A.
    Yu, Francis
    Simone II, Charles B.
    Choi, J. Isabelle
    Lee, Nancy Y.
    Kabarriti, Rafi
    Lazarev, Stanislav
    Johnson, Casey L.
    Liu, Jiayi
    Chen, Chin-Cheng
    Lin, Haibo
    CANCERS, 2023, 15 (20)
  • [28] Determining the Optimal Collimator Position for Collimated Pencil Beam Scanning Proton Therapy
    Wang, D.
    Smith, B.
    Hill, P.
    Gelover, E.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 550 - 551
  • [29] Toward automatic beam angle selection for pencil-beam scanning proton liver treatments: A deep learning-based approach
    Kaderka, Robert
    Liu, Keng-Chi
    Liu, Lawrence
    VanderStraeten, Reynald
    Liu, Tyng-Luh
    Lee, Kuang-Min
    Tu, Yi-Chin Ethan
    MacEwan, Iain
    Simpson, Daniel
    Urbanic, James
    Chang, Chang
    MEDICAL PHYSICS, 2022, 49 (07) : 4293 - 4304
  • [30] Comparison of secondary radiation dose between pencil beam scanning and scattered delivery for proton and VHEE radiotherapy
    Ronga, Maria Grazia
    Gesualdi, Flavia
    Bonfrate, Anthony
    Patriarca, Annalisa
    Ferrand, Regis
    Crehange, Gilles
    Buvat, Irene
    De Marzi, Ludovic
    MEDICAL PHYSICS, 2025,