Mapping the myelin bilayer with short-T2 MRI: Methods validation and reference data for healthy human brain

被引:9
作者
Baadsvik, Emily Louise [1 ,2 ]
Weiger, Markus [1 ,2 ]
Froidevaux, Romain [1 ,2 ]
Faigle, Wolfgang [3 ]
Ineichen, Benjamin Victor [4 ]
Pruessmann, Klaas Paul [1 ,2 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] Univ Zurich, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Univ Zurich, Univ Hosp Zurich, Neuroimmunol & MS Res Sect, Neurol Clin, Zurich, Switzerland
[4] Univ Zurich, Univ Hosp Zurich, Clin Neurosci Ctr, Dept Neuroradiol, Zurich, Switzerland
关键词
high-performance gradient; super-Lorentzian lineshape; tissue characterization; tissue preparation; ultrashort TE; white and gray matter; RESONANCE; COMPONENTS; SEQUENCES; WATER;
D O I
10.1002/mrm.29481
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To explore the properties of short-T-2 signals in human brain, investigate the impact of various experimental procedures on these properties and evaluate the performance of three-component analysis. Methods Eight samples of non-pathological human brain tissue were subjected to different combinations of experimental procedures including D2O exchange and frozen storage. Short-T-2 imaging techniques were employed to acquire multi-TE (33-2067 mu s) data, to which a three-component complex model was fitted in two steps to recover the properties of the underlying signal components and produce amplitude maps of each component. For validation of the component amplitude maps, the samples underwent immunohistochemical myelin staining. Results The signal component representing the myelin bilayer exhibited super-exponential decay with T-2,T-min of 5.48 mu s and a chemical shift of 1.07 ppm, and its amplitude could be successfully mapped in both white and gray matter in all samples. These myelin maps corresponded well to myelin-stained tissue sections. Gray matter signals exhibited somewhat different components than white matter signals, but both tissue types were well represented by the signal model. Frozen tissue storage did not alter the signal components but influenced component amplitudes. D2O exchange was necessary to characterize the non-aqueous signal components, but component amplitude mapping could be reliably performed also in the presence of H2O signals. Conclusions The myelin mapping approach explored here produced reasonable and stable results for all samples. The extensive tissue and methodological investigations performed in this work form a basis for signal interpretation in future studies both ex vivo and in vivo.
引用
收藏
页码:665 / 677
页数:13
相关论文
共 37 条
[1]   Single-point ramped imaging with T-1 enhancement (SPRITE) [J].
Balcom, BJ ;
MacGregor, RP ;
Beyea, SD ;
Green, DP ;
Armstrong, RL ;
Bremner, TW .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 123 (01) :131-134
[2]   On the biogenesis of myelin membranes: Sorting, trafficking and cell polarity [J].
Baron, Wia ;
Hoekstra, Dick .
FEBS LETTERS, 2010, 584 (09) :1760-1770
[3]   NUCLEAR MAGNETIC-RESONANCE LINE-SHAPES IN LIPID BILAYER MODEL MEMBRANES [J].
BLOOM, M ;
BURNELL, EE ;
VALIC, MI ;
WEEKS, G .
CHEMISTRY AND PHYSICS OF LIPIDS, 1975, 14 (02) :107-112
[4]   In vivo characterization of brain ultrashort-T2 components [J].
Boucneau, Tanguy ;
Cao, Peng ;
Tang, Shuyu ;
Han, Misung ;
Xu, Duan ;
Henry, Roland G. ;
Larson, Peder E. Z. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) :726-735
[5]   Symmetrically biased T/R switches for NMR and MRI with microsecond dead time [J].
Brunner, David O. ;
Furrer, Lukas ;
Weiger, Markus ;
Baumberger, Werner ;
Schmid, Thomas ;
Reber, Jonas ;
Dietrich, Benjamin E. ;
Wilm, Bertram J. ;
Froidevaux, Romain ;
Pruessmann, Klaas P. .
JOURNAL OF MAGNETIC RESONANCE, 2016, 263 :147-155
[6]   Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner [J].
Du, Jiang ;
Ma, Guolin ;
Li, Shihong ;
Carl, Michael ;
Szeverenyi, Nikolaus M. ;
VandenBerg, Scott ;
Corey-Bloom, Jody ;
Bydder, Graeme M. .
NEUROIMAGE, 2014, 87 :32-41
[7]  
Ercan E., 2012, P ISMRM 20 ANN M EXH, P4279
[8]   The effect of freezing and thawing on the magnetic resonance imaging parameters of water in beef, lamb and pork meat [J].
Evans, SD ;
Nott, KP ;
Kshirsagar, AA ;
Hall, LD .
INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 1998, 33 (03) :317-328
[9]   Yet more evidence that myelin protons can be directly imaged with UTE sequences on a clinical 3T scanner: Bicomponent <mml:msubsup>T2*</mml:msubsup> analysis of native and deuterated ovine brain specimens [J].
Fan, Shu-Juan ;
Ma, Yajun ;
Zhu, Yanchun ;
Searleman, Adam ;
Szeverenyi, Nikolaus M. ;
Bydder, Graeme M. ;
Du, Jiang .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) :538-547
[10]   Inversion recovery ultrashort echo time imaging of ultrashort T2 tissue components in ovine brain at 3 T: a sequential D2O exchange study [J].
Fan, Shu-Juan ;
Ma, Yajun ;
Chang, Eric Y. ;
Bydder, Graeme M. ;
Du, Jiang .
NMR IN BIOMEDICINE, 2017, 30 (10)