Preliminary study on the computer-based optokinetic nystagmus analyzer to detect the visual acuity of preschool children
被引:1
作者:
Min, Xia
论文数: 0引用数: 0
h-index: 0
机构:
Weihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R ChinaWeihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R China
Min, Xia
[1
]
UL Rehman, Faisal
论文数: 0引用数: 0
h-index: 0
机构:
Qingdao Univ, Qingdao Univ, Affiliated Hosp, Qingdao, Shangdong, Peoples R China
Univ Petr Huadong, Dept Res & Dev, Pengfengcheng Med Technol, Qingdao, Shangdong, Peoples R ChinaWeihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R China
UL Rehman, Faisal
[2
,3
]
Jing, Wang
论文数: 0引用数: 0
h-index: 0
机构:
Weihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R ChinaWeihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R China
Jing, Wang
[1
]
Nan, Chen
论文数: 0引用数: 0
h-index: 0
机构:
Weihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R ChinaWeihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R China
Nan, Chen
[1
]
Cheng, Che
论文数: 0引用数: 0
h-index: 0
机构:
Univ Petr Huadong, Dept Management & Mkt, Qingdao, Shangdong, Peoples R ChinaWeihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R China
Cheng, Che
[4
]
Yu, Song
论文数: 0引用数: 0
h-index: 0
机构:
Weihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R ChinaWeihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R China
Yu, Song
[1
]
机构:
[1] Weihai Cent Hosp, Dept Ophthalmol, Weihai, Shandong, Peoples R China
[2] Qingdao Univ, Qingdao Univ, Affiliated Hosp, Qingdao, Shangdong, Peoples R China
[3] Univ Petr Huadong, Dept Res & Dev, Pengfengcheng Med Technol, Qingdao, Shangdong, Peoples R China
[4] Univ Petr Huadong, Dept Management & Mkt, Qingdao, Shangdong, Peoples R China
The purpose of this study is to examine the viability, precision, and consistency of a computer-based optokinetic nystagmus analyzer (nystagmus meter) for diagnosing eyesight in preschoolers. A total of 59 subjects who could pass the log of minimum angle of resolution (LogMAR) visual acuity chart were divided into three groups by age, 4-, 5-, and 6-year-old groups, and their visual acuity was tested with nystagmus meter. The percentage of children in each age group that could be detected by nystagmus was recorded along with the differences between these groups. The correlation between the test results from the two methods was found for each age group using the correlation coefficient method. Repeated measurements were used to assess the two visual acuity values of the measured nystagmus, and the repeatability of the two measurement techniques for different age groups was compared. The overall measurability of the visual acuity detected by nystagmus was 93.22%, and the measurability of the 4-, 5-, and 6-year-old groups was 90%, 95%, and 94.74%, respectively. There was no statistically significant difference in the measurability of subjects among all age groups (P = 1.0). The outcomes of the LogMAR visual acuity chart had a negative correlation with the visual acuity measured by the nystagmus meter. The overall correlation coefficient R value was -0.80, and the correlation coefficient R value of the 4-, 5-, and 6-year-old groups was -0.79, -0.76, and -0.87, respectively. The nystagmus meter has good feasibility, accuracy, and stability in visual acuity testing and can be used for visual acuity testing in children.
引用
收藏
页码:S162 / S166
页数:5
相关论文
共 22 条
[21]
VIEFHUES T K, 1958, Albrecht Von Graefes Arch Ophthalmol, V160, P263, DOI 10.1007/BF00689900