Optimizing Solar Parabolic Trough Receivers with External Fins: An Experimental Study on Enhancing Heat Transfer and Thermal Efficiency

被引:5
作者
Limboonruang, Teerapath [1 ]
Oyinlola, Muyiwa [1 ]
Harmanto, Dani [1 ]
Bunyawanichakul, Pracha [2 ]
Phunapai, Nittalin [2 ]
机构
[1] De Montfort Univ, Inst Energy & Sustainable Dev IESD, Leicester LE1 9BH, England
[2] Srinakharinwirot Univ, Fac Engn, Dept Mech Engn, Innovat Dev Automat Syst & Sustainabil Lab I DASS, Bangkok 10110, Thailand
关键词
solar parabolic trough; solar energy; absorber tubes; renewable energy; fins tube; SEMICIRCULAR ABSORBER TUBE; TRANSFER ENHANCEMENT; COLLECTOR; NANOFLUID; ENERGY; PERFORMANCE; GENERATION; COATINGS; DESIGN; PLANTS;
D O I
10.3390/en16186520
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Several researchers have shown that the heat transfer performance of solar parabolic trough (SPT) receivers may be improved by increasing their surface area or by adding internal fins to the tubes. Unfortunately, the manufacture of internally finned tubes involves complex processes, resulting in significant cost increases. On the other hand, the addition of external fins to tubes is more technically and economically feasible in a low-resource setting. This study investigates the potential benefits of integrating external fins on the receiver tubes of a low-cost SPT collector system. Experiments were conducted using an SPT system with a focal length of 300 mm and a collector length of 5.1 m, and they were positioned by an automated Sun tracking system. Tests were undertaken using both smooth and externally finned receiver tubes operating at five different water flow rates. The solar receiver with a finned tube was able to provide a maximum water temperature of 59.34 degrees C compared with that of 56.52 degrees C for a smooth tube at a flow rate of 0.5 L per minute. The externally finned absorber tube was also found to have a maximum efficiency of 18.20% at an average daily solar intensity of 834.61 W/m2, which is approximately 48% more efficient than the smooth tube. The calculations indicate that the experimental SPT system using finned tubes potentially avoids 0.2726 metric tons of CO2e per year, with finned tubes outperforming smooth tubes by up to 44%. The results show that using externally finned receiver tubes can significantly enhance the thermal performance of SPT collector systems.
引用
收藏
页数:22
相关论文
共 82 条
[1]   Thermal performance evaluation of various nanofluids with non-uniform heating for parabolic trough collectors [J].
Abed, Nabeel ;
Afgan, Imran ;
Cioncolini, Andrea ;
Iacovides, Hector ;
Nasser, Adel ;
Mekhail, Tarek .
CASE STUDIES IN THERMAL ENGINEERING, 2020, 22
[2]  
Agency I.E, 2016, Thailand Electricity Security Assessment
[3]   Insight into the Dynamics of Oldroyd-B Fluid Over an Upper Horizontal Surface of a Paraboloid of Revolution Subject to Chemical Reaction Dependent on the First-Order Activation Energy [J].
Ali, Z. ;
Zeeshan, A. ;
Bhatti, M. M. ;
Hobiny, Aatef ;
Saeed, T. .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2021, 46 (06) :6039-6048
[4]  
[Anonymous], 2003, 932003 ANSIASHRAE
[5]   Design, manufacture and testing of fiberglass reinforced parabola trough for parabolic trough solar collectors [J].
Arasu, A. Valan ;
Sornakumar, T. .
SOLAR ENERGY, 2007, 81 (10) :1273-1279
[6]  
Arjharn W., Study of the Economy Cost of a Small Scale Biomass Power Plant for Rural Communities
[7]   Carbon Footprint of Faculty of Environment and Resource Studies, Mahidol University, Salaya Campus, Thailand [J].
Aroonsrimorakot, Sayam ;
Yuwaree, Chumporn ;
Arunlertaree, Chumlong ;
Hutajareorn, Rungjarus ;
Buadit, Tarinee .
4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND DEVELOPMENT- ICESD 2013, 2013, 5 :175-180
[8]   Estimation of capital costs and techno-economic appraisal of parabolic trough solar collector and solar power tower based CSP plants in India for different condenser cooling options [J].
Aseri, Tarun Kumar ;
Sharma, Chandan ;
Kandpal, Tara C. .
RENEWABLE ENERGY, 2021, 178 :344-362
[9]   Selective properties of high-temperature stable spinel absorber coatings for concentrated solar thermal application [J].
Atchuta, S. R. ;
Sakthivel, S. ;
Barshilia, Harish C. .
SOLAR ENERGY, 2020, 199 :453-459
[10]   Optimal design of wind-powered hydrogen refuelling station for some selected cities of South Africa [J].
Ayodele, T. R. ;
Mosetlhe, T. C. ;
Yusuff, A. A. ;
Ntombela, M. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (49) :24919-24930