Study of the operating characteristics of a pump-driven thermosyphon loop with gas-liquid separation

被引:4
|
作者
Wang, Leixin [1 ]
Cheng, Hao [1 ]
Yang, Tongzhi [1 ]
Zhao, Yifan [1 ]
Yuan, Weixing [1 ,3 ]
Ren, Kexian [2 ,3 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Lab Ergon & Environm Control, 37 Xueyuan Rd, Beijing 100191, Peoples R China
[2] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
[3] Xiang Yang Solergy Technol Co Ltd, Xiangyang 441000, Peoples R China
关键词
Pump-driven; Thermosyphon loop; Gas-liquid separation; Data center; High efficiency; HEAT-PIPE SYSTEM; DATA CENTERS; THERMAL MANAGEMENT; COOLING SYSTEM; PERFORMANCE; FLOW; RECOVERY; UNIT;
D O I
10.1016/j.applthermaleng.2023.121265
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pump-driven thermosyphon loop (PDTL) is a highly efficient cooling method for air-conditioning systems in data centers. Typically, the refrigerant in gas-liquid two-phase state leads to significant pressure drop in pipes following evaporator, which results in more energy consumption for data centers cooling. This study proposes a novel PDTL with gas-liquid separation (PDTLGLS), aiming to separate the gas-liquid phase refrigerant into liquid phase and gas phase, to reduce pressure drop following evaporator and improve the PDTL performance using a gas-liquid separator. Driven by the pressure difference between the gas-liquid separator and the reservoir, the gas-phase refrigerant is condensed into liquid-phase refrigerant back to the reservoir and the liquid-phase refrigerant returns to a reservoir directly without heat exchanging. This paper firstly conducted a theoretical analysis of PDTLGLS. Then the experiments were conducted using R134a to investigate the influence of refrig-erant flow rate and heating power on the performance of PDTLGLS. Furthermore, transient characteristics of the PDTLGLS were experimentally analyzed by varying the heating power. The experimental results show that the PDTLGLS achieves 36.8%-53.3% less heat dissipation temperature difference (from evaporator to condenser) and 28.3%-33.3% higher EER than traditional PDTL, and lower dryness could enlarge the PDTLGLS advantages. Furthermore, both analysis results and experimental results show that the PDTLGLS can adjust to diverse refrigerant mass flow and heating power via the self-regulation of the liquid height in the gas-liquid separator, which implies that the PDTLGLS is an effective way to enhance the traditional PDTL performance and could sustain stable operation across a broad spectrum of operating conditions.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Experimental research on boiling heat transfer mechanism of a pump-driven loop thermosiphon for R134a coolant
    Ding, Tao
    Chen, Xiaoxuan
    Zhao, Tian
    Zhu, Chaoyi
    Zhang, Hainan
    Li, Zhen
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2024, 107
  • [12] Experimental study on operating characteristics of a controllable CO2 two-phase thermosyphon loop
    Tong, Zhen
    Wang, Wencheng
    Wu, Hao
    Zhu, Zhaolong
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 49
  • [13] Experimental study on a swirl-vane separator for gas-liquid separation
    Wang, Gang
    Yan, Changqi
    Fan, Guangming
    Wang, Jianjun
    Xu, Junxiu
    Zeng, Xiaobo
    Liu, Antai
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 151 : 108 - 119
  • [14] Study of gas-liquid interface displacement in capillary driven by gas pressurization
    Bahrini, Imen
    Faycel, Khemili
    2015 World Symposium on Mechatronics Engineering & Applied Physics (WSMEAP), 2015,
  • [15] Experimental study on the boiling heat transfer characteristics of a pump-driven two-phase cooling loop system for high heat flux avionics
    Wang, Jiaxuan
    Yu, Binbin
    Qian, Chenyi
    Shi, Junye
    Chen, Jiangping
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 45
  • [16] Energy-saving analysis of a case data center with a pump-driven loop heat pipe system in different climate regions in China
    Zhou, Feng
    Li, Cuicui
    Zhu, Wanpeng
    Zhou, Jing
    Ma, Guoyuan
    Liu, Zhongliang
    ENERGY AND BUILDINGS, 2018, 169 : 295 - 304
  • [17] Gas-liquid separation mechanisms and bubble dynamics in a helical axial multiphase flow pump
    Quan, Hui
    Li, Jiayi
    Sun, Jun
    Shi, Guangtai
    Li, Yifei
    Li, Yuan
    Qiao, Jinyu
    Li, Yinqiang
    PHYSICS OF FLUIDS, 2025, 37 (02)
  • [18] Gas-Liquid Interaction Characteristics in a Multiphase Pump under Different Working Conditions
    Deng, Yuxuan
    Wang, Xiaodong
    Xu, Jing
    Li, Yanna
    Zhang, Yanli
    Kuang, Chunyan
    PROCESSES, 2022, 10 (10)
  • [19] Simulation Study of Space Spiral Gas-Liquid Separation Technology
    Si Pingjun
    Wang Hua
    Cui Cunyan
    Chen Yuan
    MATERIALS, MECHANICAL ENGINEERING AND MANUFACTURE, PTS 1-3, 2013, 268-270 : 902 - 905
  • [20] Experimental study of gas-liquid two-phase operating characteristics and bubble evolution law of a semi-open mixed-flow pump
    Luo, Xingqi
    Yan, Sina
    Sun, Shuaihui
    Feng, Jianjun
    Xie, Hang
    Zhang, Lefu
    He, Denghui
    OCEAN ENGINEERING, 2023, 272