Machine learning and reduced order modelling for the simulation of braided stent deployment

被引:10
作者
Bisighini, Beatrice [1 ,2 ,3 ]
Aguirre, Miquel [1 ,4 ,5 ]
Biancolini, Marco Evangelos [3 ]
Trovalusci, Federica [3 ]
Perrin, David [2 ]
Avril, Stephane [1 ]
Pierrat, Baptiste [1 ]
机构
[1] Univ Lyon, Univ Jean Monnet, Mines St Etienne, INSERM, St Etienne, France
[2] Grande Usine Creat 2, Predisurge, St Etienne, France
[3] Univ Tor Vergata, Dept Enterprise Engn, Rome, Italy
[4] Univ Politecn Cataluna, Lab Calcul Numer, Barcelona, Spain
[5] Gran Capita, Int Ctr Numer Methods Engn CIMNE, Barcelona, Spain
关键词
braided stent; beam elements; contact mechanics; reduced order modelling; machine learning; UNRUPTURED INTRACRANIAL ANEURYSMS; FLOW DIVERSION; SIZE RATIO; IN-VITRO; RUPTURE; PREVALENCE; VALIDATION;
D O I
10.3389/fphys.2023.1148540
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Endoluminal reconstruction using flow diverters represents a novel paradigm for the minimally invasive treatment of intracranial aneurysms. The configuration assumed by these very dense braided stents once deployed within the parent vessel is not easily predictable and medical volumetric images alone may be insufficient to plan the treatment satisfactorily. Therefore, here we propose a fast and accurate machine learning and reduced order modelling framework, based on finite element simulations, to assist practitioners in the planning and interventional stages. It consists of a first classification step to determine a priori whether a simulation will be successful (good conformity between stent and vessel) or not from a clinical perspective, followed by a regression step that provides an approximated solution of the deployed stent configuration. The latter is achieved using a non-intrusive reduced order modelling scheme that combines the proper orthogonal decomposition algorithm and Gaussian process regression. The workflow was validated on an idealized intracranial artery with a saccular aneurysm and the effect of six geometrical and surgical parameters on the outcome of stent deployment was studied. We trained six machine learning models on a dataset of varying size and obtained classifiers with up to 95% accuracy in predicting the deployment outcome. The support vector machine model outperformed the others when considering a small dataset of 50 training cases, with an accuracy of 93% and a specificity of 97%. On the other hand, real-time predictions of the stent deployed configuration were achieved with an average validation error between predicted and high-fidelity results never greater than the spatial resolution of 3D rotational angiography, the imaging technique with the best spatial resolution (0.15 mm). Such accurate predictions can be reached even with a small database of 47 simulations: by increasing the training simulations to 147, the average prediction error is reduced to 0.07 mm. These results are promising as they demonstrate the ability of these techniques to achieve simulations within a few milliseconds while retaining the mechanical realism and predictability of the stent deployed configuration.
引用
收藏
页数:18
相关论文
共 68 条
  • [1] An implicit 3D corotational formulation for frictional contact dynamics of beams against rigid surfaces using discrete signed distance fields
    Aguirre, Miquel
    Avril, Stephane
    [J]. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2020, 371
  • [2] Carotid artery stenting simulation: From patient-specific images to finite element analysis
    Auricchio, F.
    Conti, M.
    De Beule, M.
    De Santis, G.
    Verhegghe, B.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2011, 33 (03) : 281 - 289
  • [3] Fast simulations of patient-specific haemodynamics of coronary artery bypass grafts based on a POD-Galerkin method and a vascular shape parametrization
    Ballarin, Francesco
    Faggiano, Elena
    Ippolito, Sonia
    Manzoni, Andrea
    Quarteroni, Alfio
    Rozza, Gianluigi
    Scrofani, Roberto
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 2016, 315 : 609 - 628
  • [4] Supremizer stabilization of POD-Galerkin approximation of parametrized steady incompressible Navier-Stokes equations
    Ballarin, Francesco
    Manzoni, Andrea
    Quarteroni, Alfio
    Rozza, Gianluigi
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2015, 102 (05) : 1136 - 1161
  • [5] Fast interactive CFD evaluation of hemodynamics assisted by RBF mesh morphing and reduced order models: the case of aTAA modelling
    Biancolini, Marco Evangelos
    Capellini, Katia
    Costa, Emiliano
    Groth, Corrado
    Celi, Simona
    [J]. INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2020, 14 (04): : 1227 - 1238
  • [6] Virtual human bone modelling by interactive sculpting, mesh morphing and force-feedback
    Biancolini M.E.
    Valentini P.P.
    [J]. International Journal on Interactive Design and Manufacturing, 2018, 12 (04) : 1223 - 1234
  • [7] EndoBeams.jl: A Julia finite element package for beam-to-surface contact problems in cardiovascular mechanics
    Bisighini, Beatrice
    Aguirre, Miquel
    Pierrat, Baptiste
    Perrin, David
    Avril, Stephane
    [J]. ADVANCES IN ENGINEERING SOFTWARE, 2022, 171
  • [8] A low dimensional surrogate model for a fast estimation of strain in the thrombus during a thrombectomy procedure
    Bridio, Sara
    Luraghi, Giulia
    Migliavacca, Francesco
    Pant, Sanjay
    Garcia-Gonzalez, Alberto
    Rodriguez Matas, Jose F.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 137
  • [9] Personalising left-ventricular biophysical models of the heart using parametric physics-informed neural networks
    Buoso, Stefano
    Joyce, Thomas
    Kozerke, Sebastian
    [J]. MEDICAL IMAGE ANALYSIS, 2021, 71
  • [10] Cai Y., 2020, MED NOV TECHNOL DEVI, V5, P100031, DOI [10.1016/j.medntd.2020.100031, DOI 10.1016/J.MEDNTD.2020.100031]