Non-contact vital signs monitoring in broiler chickens

被引:1
|
作者
Hossain, Md. Shafkat [1 ]
Pramanik, Sourav Kumar [1 ]
Rahman, Atikur [1 ]
Ali, Shahin [1 ]
Islam, Shekh Md Mahmudul [1 ]
机构
[1] Univ Dhaka, Dept Elect & Elect Engn, Dhaka 1000, Bangladesh
来源
JOURNAL OF ENGINEERING-JOE | 2023年 / 2023卷 / 11期
关键词
non-contact animal monitoring; radar applications; radar detection; radar signal processing; radar vital signs monitoring;
D O I
10.1049/tje2.12320
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Measuring the heartbeat and respiration of animals continuously can provide valuable information about their health status. Respiratory-related diseases are very common in the poultry industry and unfortunately, there is no non-contact respiratory monitoring system for measuring the breathing rate and heart rate of the broiler chicken. In this letter, the authors explored and tested the feasibility of utilizing a 24-GHz continuous-wave (CW) radar module for monitoring the vital signs (breathing rate and heart rate) of broiler chickens. A signal processing approach has been developed to extract vital signs of broiler chicken from Radar-captured signals. The experiment was carried out on three different normal broiler chickens with the ages of 25-30 days, weight 1.18-1.6 kg where a 24-GHz radar module was mounted at a distance of 0.2 m above the chest surface of the chicken, and this particular experiment was repeated for 20 times. The authors also used a reference ECG module (Biopac System) for extracting the breathing rate and heart rate of the broiler chicken and compared the accuracy of their proposed system. Experimental results demonstrated that the radar measurement closely matches the Biopac ECG acquisition module measurement and showed an accuracy of 96% for a short-scale study. Non-Contact vital signs monitoring of broiler chickens using Radar has been demonstrated and its efficacy has been investigated.image
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A non-contact vital signs monitor
    Matthews, G
    Sudduth, B
    Burrow, M
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2000, 28 (1-2) : 173 - 178
  • [2] Non-Contact Vital Signs Monitoring Through Visible Light Sensing
    Abuella, Hisham
    Ekin, Sabit
    IEEE SENSORS JOURNAL, 2020, 20 (07) : 3859 - 3870
  • [3] DistancePPG: Robust non-contact vital signs monitoring using a camera
    Kumar, Mayank
    Veeraraghavan, Ashok
    Sabharwal, Ashutosh
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (05): : 1565 - 1588
  • [4] A Measurement Study of FMCW Radar Configurations for Non-contact Vital Signs Monitoring
    Xie, Zongxing
    Hua, Yindong
    Ye, Fan
    2022 IEEE RADAR CONFERENCE (RADARCONF'22), 2022,
  • [5] Non-Contact Vital Signs Monitoring of Dog and Cat Using a UWB Radar
    Wang, Pengfei
    Ma, Yangyang
    Liang, Fulai
    Zhang, Yang
    Yu, Xiao
    Li, Zhao
    An, Qiang
    Lv, Hao
    Wang, Jianqi
    ANIMALS, 2020, 10 (02):
  • [6] Method of Estimating Positions for Multiple People in Non-Contact Vital Signs Monitoring Systems
    Kashiwagi, Masaya
    Inoue, Toshiyuki
    Okamoto, Masanao
    Tsuchiya, Akira
    Kishine, Keiji
    2022 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2022,
  • [7] Robust Phased Array Non-Contact Vital Signs Monitoring in an Office Cubicle Setting
    Hall, T.
    Tsay, J.
    Dominguez, G.
    Boothby, A.
    Das, V.
    Lopez, J.
    Nguyen, T.
    Banister, R. E.
    Lie, D. Y. C.
    2014 INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG), 2014,
  • [8] Non-contact vital sign monitoring in the clinic
    Villarroel, Mauricio
    Jorge, Joao
    Pugh, Chris
    Tarassenko, Lionel
    2017 12TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION (FG 2017), 2017, : 278 - 285
  • [9] Extending the Range of Phased Array Non-Contact Vital Signs Monitoring in an Office Cubicle Setting
    Hall, T.
    Stout, C.
    Brewer, N.
    Dominguez, G.
    Tsay, J.
    Boothby, A.
    Das, V.
    Lopez, J.
    Nguyen, T.
    Banister, R. E.
    Lie, D. Y. C.
    2014 TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2014,
  • [10] Small Motion Detection and Non-Contact Vital Signs Monitoring with Continuous Wave Doppler Radars
    Seflek, Ibrahim
    Acar, Yunus Emre
    Yaldiz, Ercan
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2020, 26 (03) : 54 - 60