Moment capacity of eaves brackets of cold-formed steel portal frames

被引:3
作者
Chen, Xin [1 ,3 ]
Boston, Megan [2 ]
Bell, Darrin [3 ]
Roy, Krishanu [2 ]
Mares, Jiri [4 ]
Lim, James B. P. [1 ,2 ]
机构
[1] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
[2] Univ Waikato, Sch Engn, Hamilton, New Zealand
[3] Donovan Grp, 51 Hurstmere Rd, Auckland, New Zealand
[4] Czech Tech Univ, Fac Civil Engn, Prague, Czech Republic
关键词
Cold-formed steel; Moment capacity; Eaves bracket; Partially restrained; Finite element analysis; TO-COLUMN CONNECTIONS; ULTIMATE STRENGTH; ASSISTED DESIGN;
D O I
10.1016/j.tws.2023.110947
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The strength and stiffness of cold-formed steel portal frames are heavily related to the performance of their joints; these joints are normally formed through brackets, bolted to the webs of channels. Previous research in the literature has considered the strength of the apex bracket, and design equations proposed to predict its moment capacity. No similar research, however, has been undertaken for the eaves bracket. In the literature, the only design guidance found is a design chart, limited to eaves joints fully restrained against lateral torsional buckling, for use under a closing moment and an eaves bracket details having a stiffener along its hypotenuses. This paper describes a finite element study comprising 7,560 models, that addresses all these limitations. Unified equations are presented that can be used for the design of eaves brackets in practical partially restrained eaves joints, as found in New Zealand practice, both closing and opening moments, and different arrangements of stiffeners in the detail of the eaves bracket.
引用
收藏
页数:15
相关论文
共 29 条
[1]  
AISI (American Iron and Steel Institute), 2016, S100 ANSI
[2]  
[Anonymous], 2006, Eurocode 3: Design of Steel StructuresPart 13: General RulesSupplementary Rules for Cold-Formed Members and Sheeting
[3]  
[Anonymous], 2014, ABAQUSCAE US GUID V6
[4]  
Australia/New Zealand Standard (AS/NZS), 2018, AS/NZS 4600:2018
[5]   STRUCTURAL-ANALYSIS OF ASSEMBLAGES OF THIN-WALLED MEMBERS [J].
BAIGENT, AH ;
HANCOCK, GJ .
ENGINEERING STRUCTURES, 1982, 4 (03) :207-216
[6]   Seismic response of MRFs with partially-restrained bolted beam-to-column connections through FE analyses [J].
Brunesi, E. ;
Nascimbene, R. ;
Rassati, G. A. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 107 :37-49
[7]   Response of partially-restrained bolted beam-to-column connections under cyclic loads [J].
Brunesi, E. ;
Nascimbene, R. ;
Rassati, G. A. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 97 :24-38
[8]   Cold-formed steel portal frame moment-resisting joints: Behaviour, capacity and design [J].
Chen, Xin ;
Blum, H. B. ;
Roy, Krishanu ;
Pouladi, Pouya ;
Uzzaman, Asraf ;
Lim, James B. P. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 183
[9]   Finite element modeling of bolted connections between cold-formed steel strips and hot rolled steel plates under static shear loading [J].
Chung, KF ;
Ip, KH .
ENGINEERING STRUCTURES, 2000, 22 (10) :1271-1284
[10]  
Dubbina D., 2004, P 17 INT SPECIALITY