Is sequential bilateral robotic total knee arthroplasty a safe procedure? A matched comparative pilot study

被引:12
作者
Batailler, Cecile [1 ]
Anderson, Mike B. [2 ]
Flecher, Xavier [3 ]
Ollivier, Matthieu [3 ]
Parratte, Sebastien [3 ,4 ]
机构
[1] Lyon Univ Hosp, Croix Rousse Hosp, Dept Orthopaed Surg, Lyon, France
[2] Zimmer GmbH, Salt Lake City, UT USA
[3] Aix Marseille Univ, Inst Movement & Locomot, Dept Orthoped & Traumatol, St Marguerite Hosp,APHM,CNRS,ISM, Marseille, France
[4] Int Knee & Joint Ctr, Dept Orthopaed Surg, Abu Dhabi, U Arab Emirates
关键词
Total knee arthroplasty; Sequential bilateral TKA; Robotic-assisted surgery; Blood loss; ROSA; BLOOD-LOSS; TRANEXAMIC ACID; PAIN LEVELS; REPLACEMENT; TRANSFUSION; INFECTION; ALIGNMENT; RECOVERY; OUTCOMES; TIME;
D O I
10.1007/s00402-022-04455-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction To our knowledge, no papers have reported the results of robotic-assisted surgery for sequential bilateral Total Knee Arthroplasty (TKA). Indeed, sequential bilateral TKA present several benefits, as one single anesthesia, surgical episode, hospitalization, and rehabilitation. The purpose of our study was to evaluate peri-operative outcomes and compare the complication rates, clinical outcomes, and implant positioning of sequential bilateral TKA performed with a robotic-assisted system versus a conventional technique. Materials and methods All patients who underwent a sequential bilateral robotic-assisted primary TKA (raTKA) in our institution between November 2019 and February 2021 were included. Twenty patients met the inclusion criteria and were matched with 20 sequential bilateral TKA performed with a conventional technique. The two groups were comparable for the demographic data and the preoperative parameters, including preoperative anticoagulation and ASA score. The minimum follow-up was 6 months. Results The operative time was significantly longer in the robotic group (< 0.0001), with a mean additional time of 29 min. There was no significant difference between both groups for postoperative blood loss, rate of blood transfusion, or postoperative pain. The average length of stay was 5 days. There was one early complication in the robotic group due to the tibial trackers. The functional outcomes were similar between both groups, except for the functional KSS score, which was better at 6 months in the robotic group (p < 0.0001). The restoration of the knee alignment and the distal femoral anatomy were significantly better in the robotic group than in the conventional group. Conclusions Despite a longer operative time, the peri-operative parameters of sequential bilateral TKA were similar between robotic and conventional techniques. Further, sequential bilateral raTKA was at least as safe as a conventional technique, without additional risk of medical complications.
引用
收藏
页码:1599 / 1609
页数:11
相关论文
共 68 条
[1]   Comparison of simultaneous bilateral versus unilateral total knee replacement on pain levels and functional recovery [J].
Alghadir, Ahmad H. ;
Iqbal, Zaheen A. ;
Anwer, Shahnawaz ;
Anwar, Dilshad .
BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
[2]   Test-retest reliability, validity, and minimum detectable change of visual analog, numerical rating, and verbal rating scales for measurement of osteoarthritic knee pain [J].
Alghadir, Ahmad H. ;
Anwer, Shahnawaz ;
Iqbal, Amir ;
Iqbal, Zaheen Ahmed .
JOURNAL OF PAIN RESEARCH, 2018, 11 :851-856
[3]  
Bach CM, 2002, CLIN ORTHOP RELAT R, P184
[4]   Tranexamic Acid Decreases Incidence of Blood Transfusion in Simultaneous Bilateral Total Knee Arthroplasty [J].
Bagsby, Deren T. ;
Samujh, Christopher A. ;
Vissing, Jacqueline L. ;
Empson, Janene A. ;
Pomeroy, Donald L. ;
Malkani, Arthur L. .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2106-2109
[5]   Bilateral total knee replacement: Staging and pulmonary embolism [J].
Barrett, Jane ;
Baron, John A. ;
Losina, Elena ;
Wright, John ;
Mahomed, Nizar N. ;
Katz, Jeffrey N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2146-2151
[6]   Concepts and techniques of a new robotically assisted technique for total knee arthroplasty: the ROSA knee system [J].
Batailler, Cecile ;
Hannouche, Didier ;
Benazzo, Francesco ;
Parratte, Sebastien .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) :2049-2058
[7]   MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review [J].
Batailler, Cecile ;
Fernandez, Andrea ;
Swan, John ;
Servien, Elvire ;
Haddad, Fares S. ;
Catani, Fabio ;
Lustig, Sebastien .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (11) :3585-3598
[8]   Pin track induced fractures around computer-assisted TKA [J].
Beldame, J. ;
Boisrenoult, P. ;
Beaufils, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) :249-255
[9]   Robotic-assisted total knee arthroplasty demonstrates decreased postoperative pain and opioid usage compared to conventional total knee arthroplasty [J].
Bhimani, S. J. ;
Bhimani, R. ;
Smith, A. ;
Eccles, C. ;
Smith, L. ;
Malkani, A. .
BONE & JOINT OPEN, 2020, 1 (02) :8-12
[10]   ESTIMATING ALLOWABLE HEMODILUTION [J].
BOURKE, DL ;
SMITH, TC .
ANESTHESIOLOGY, 1974, 41 (06) :609-612