Dose assesment with fast Monte Carlo codes in interventional radiology

被引:2
作者
Balcaza, V. Garcia [1 ]
Camp, A. [1 ]
Sanchez, R. M. [2 ]
Ginjaume, M. [1 ]
Duch, M. A. [1 ]
机构
[1] Univ Politecn Catalunya UPC, Inst Tecn Energet, Ave Diagonal 647, Barcelona 08028, Spain
[2] Hosp Clin San Carlos, Fdn Invest Biomed Hosp Clin San Carlos FIBHCSC, 4 Sur,Calle Profesor Martin Lagos, Madrid 28040, Spain
关键词
D O I
10.1093/rpd/ncac244
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator. The experiments are performed in a calibration laboratory and measurements are gathered using Thermo EPD and Mirion DMC personal active dosemeters. Calculation efficiency of the fast Monte Carlo codes is approximately four orders of magnitude greater than for a standard Monte Carlo code. Satisfactory agreement between measurements and calculations is shown.
引用
收藏
页码:1813 / 1817
页数:5
相关论文
共 13 条
  • [1] PERSONAL DOSIMETRY USING MONTE-CARLO SIMULATIONS FOR OCCUPATIONAL DOSE MONITORING IN INTERVENTIONAL RADIOLOGY: THE RESULTS OF A PROOF OF CONCEPT IN A CLINICAL SETTING
    Almen, A.
    Andersson, M.
    O'Connor, U.
    Abdelrahman, M.
    Camp, A.
    Garcia, V
    Duch, M. A.
    Ginjaume, M.
    Vanhavere, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) : 391 - 398
  • [2] [Anonymous], 1997, Ann ICRP, V27, P1
  • [3] [Anonymous], 2010, NIST STANDARD REFERE
  • [4] [Anonymous], 2005, IEC 61267 Edition 2.0.
  • [5] Badal A., 2013, SPIE Med. Imaging, V8668
  • [6] Fast Monte Carlo codes for occupational dosimetry in interventional radiology
    Garcia Balcaza, V
    Camp, A.
    Badal, A.
    Andersson, M.
    Almen, A.
    Ginjaume, M.
    Duch, M. A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 166 - 174
  • [7] Garcia-Balcaza V., 2022, IRPA2022 C MAY 30 JU
  • [8] International Organization for Standarization, 2019, Radiological protection-X and gamma reference radiation for calibrating dosemeters and dose rate meters and for determining their response as a function of photon energy-Part 3: calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
  • [9] Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals
    O'Connor, U.
    Carinou, E.
    Clairand, I.
    Ciraj-Bjelac, O.
    De Monte, F.
    Domienik-Andrzejewska, J.
    Ferrari, P.
    Ginjaume, M.
    Hrsak, H.
    Hupe, O.
    Knezevic, Z.
    Merce, M. Sans
    Sarmento, S.
    Siiskonen, T.
    Vanhavere, F.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 131 - 135
  • [10] O'Connor U., 2022, J. Radiol. Prot, V42