Validity of artificial intelligence-based markerless motion capture system for clinical gait analysis: Spatiotemporal results in healthy adults and adults with Parkinson's disease

被引:8
作者
Ripic, Zachary [1 ,3 ]
Signorile, Joseph F. [1 ,2 ]
Best, Thomas M. [3 ,4 ]
Jacobs, Kevin A. [1 ]
Nienhuis, Mitch [1 ]
Whitelaw, Cole [1 ]
Moenning, Caden [1 ]
Eltoukhy, Moataz [1 ,5 ]
机构
[1] Univ Miami, Dept Kinesiol & Sport Sci, Miami, FL 33124 USA
[2] Univ Miami, Ctr Aging, Miller Sch Med, Miami, FL USA
[3] Univ Miami, Sports Med Inst, Miller Sch Med, Miami, FL USA
[4] Univ Miami, Dept Orthopaed, Miller Sch Med, Miami, FL USA
[5] Univ Miami, Dept Ind & Syst Engn, Miami, FL USA
关键词
Gait analysis; Human pose estimation; Markerless motion capture; Artificial intelligence; Computer vision; KINECT V2; TREADMILL;
D O I
10.1016/j.jbiomech.2023.111645
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Markerless motion capture methods are continuously in development to target limitations encountered in marker-, sensor-, or depth-based systems. Previous evaluation of the KinaTrax markerless system was limited by differences in model definitions, gait event methods, and a homogenous subject sample. The purpose of this work was to evaluate the accuracy of spatiotemporal parameters in the markerless system with an updated markerless model, coordinate-and velocity-based gait events, and subjects representing young adult, older adult, and Parkinson's disease groups. Fifty-seven subjects and 216 trials were included in this analysis. Interclass corre-lation coefficients showed excellent agreement between the markerless system and a marker-based reference system for all spatial parameters. Temporal variables were similar, except swing time which showed good agreement. Concordance correlation coefficients were similar with all but swing time showing moderate to almost perfect concordance. Bland-Altman bias and limits of agreement (LOA) were small and improved from previous evaluations. Parameters showed similar agreement across coordinate-and velocity-based gait methods with the latter showing generally smaller LOAs. Improvements in spatiotemporal parameters in the present evaluation was due to inclusion of keypoints at the calcanei in the markerless model. Consistency in the calcanei keypoints relative to heel marker placements may improve results further. Similar to previous work, LOAs are within boundaries to detect differences in clinical groups. Results support the use of the markerless system for estimation of spatiotemporal parameters across age and clinical groups, but caution should be taken when generalizing findings due to remaining error in kinematic gait event methods.
引用
收藏
页数:7
相关论文
共 37 条
  • [1] Validity Analysis of WalkerViewTM Instrumented Treadmill for Measuring Spatiotemporal and Kinematic Gait Parameters
    Bravi, Marco
    Massaroni, Carlo
    Santacaterina, Fabio
    Di Tocco, Joshua
    Schena, Emiliano
    Sterzi, Silvia
    Bressi, Federica
    Miccinilli, Sandra
    [J]. SENSORS, 2021, 21 (14)
  • [2] A review of 3D human pose estimation algorithms for markerless motion capture
    Desmarais, Yann
    Mottet, Denis
    Slangen, Pierre
    Montesinos, Philippe
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 2021, 212
  • [3] Walking in the Absence of Anterior Cruciate Ligament: The Role of the Quadriceps and Hamstrings
    Donno, Lucia
    Sansone, Valerio
    Galluzzo, Alessandro
    Frigo, Carlo Albino
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (17):
  • [4] Validation of an ambient system for the measurement of gait parameters
    Dubois, Amandine
    Bresciani, Jean-Pierre
    [J]. JOURNAL OF BIOMECHANICS, 2018, 69 : 175 - 180
  • [5] Prediction of ground reaction forces for Parkinson's disease patients using a kinect-driven musculoskeletal gait analysis model
    Eltoukhy, Moataz
    Kuenze, Christopher
    Andersen, Michael S.
    Oh, Jeonghoon
    Signorile, Joseph
    [J]. MEDICAL ENGINEERING & PHYSICS, 2017, 50 : 75 - 82
  • [6] Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments
    Geerse, Daphne J.
    Coolen, Bert H.
    Roerdink, Melvyn
    [J]. PLOS ONE, 2015, 10 (10):
  • [7] Goodfellow I, 2016, ADAPT COMPUT MACH LE, P1
  • [8] The Accuracy of the Microsoft Kinect V2 Sensor for Human Gait Analysis. A Different Approach for Comparison with the Ground Truth
    Guffanti, Diego
    Brunete, Alberto
    Hernando, Miguel
    Rueda, Javier
    Navarro Cabello, Enrique
    [J]. SENSORS, 2020, 20 (16) : 1 - 14
  • [9] Defining the Clinically Meaningful Difference in Gait Speed in Persons With Parkinson Disease
    Hass, Chris J.
    Bishop, Mark
    Moscovich, Mariana
    Stegemoeller, Elizabeth L.
    Skinner, Jared
    Malaty, Irene A.
    Shukla, Aparna Wagle
    McFarland, Nikolaus
    Okun, Michael S.
    [J]. JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2014, 38 (04): : 233 - 238
  • [10] Deep Residual Learning for Image Recognition
    He, Kaiming
    Zhang, Xiangyu
    Ren, Shaoqing
    Sun, Jian
    [J]. 2016 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2016, : 770 - 778