A flexible multifunctional electrode based on conducting PANI/Pd composite for non-enzymatic glucose sensor and direct alcohol fuel cell applications

被引:12
|
作者
Eswaran, Muthusankar [1 ]
Rahimi, Shadi [1 ]
Pandit, Santosh [1 ]
Chokkiah, Bavatharani [2 ,3 ]
Mijakovic, Ivan [1 ,4 ]
机构
[1] Chalmers Univ Technol, Dept Biol & Biol Engn, Div Syst & Synthet Biol, SE-41296 Gothenburg, Sweden
[2] Karpagam Acad Higher Educ, Ctr Mat Chem, Coimbatore 641046, Tamilnadu, India
[3] Karpagam Acad Higher Educ, Dept Sci & Humanities, Coimbatore 641046, Tamilnadu, India
[4] Tech Univ Denmark, Novo Nord Fdn Ctr Biosustainabil, DK-2800 Lyngby, Denmark
基金
瑞典研究理事会;
关键词
Glucose sensor; Direct alcohol fuel cells; Polyaniline; Palladium; Flexible electrode; REDUCED GRAPHENE OXIDE; PALLADIUM NANOPARTICLES; FACILE SYNTHESIS; POLYANILINE; METHANOL; NANOCOMPOSITES; ELECTROOXIDATION; NANOSHEETS; OXIDATION;
D O I
10.1016/j.fuel.2023.128182
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work, we fabricated a flexible, multifunctional polyimide (PI)/Au-polyaniline (PAN)/Pd nanocomposite electrode with excellent electrochemical properties. Structural geometry, morphological views, and functional group analyses indicated that the physicochemical and electrochemical performance of the electrode is based on the strong and synergistic metal-polymer interaction between the conducting PAN and Pd, which ensured high conductivity, rapid response, and high electron transfer rate through more electroactive spots available in the nanocomposite. Here, we demonstrated that the fabricated PI/Au-PAN/Pd electrodes can be successfully used for biomedical sensing of glucose, as well as for energy conversion application, using the oxidation of alcohols such as methanol and ethanol in fuel cells. The electrochemical analysis shows that the flexible sensor (PI/Au-PAN/ Pd) has ultra-high sensitivity of 2140 mu A/mu M.cm2 with a low detection limit of 0.3 mu M for glucose. Also, the interference analysis, reproducibility, and stability studies reveal its excellent capability for glucose sensing. Furthermore, the electrode also demonstrates prominent electrocatalytic behavior to the electrooxidation of methanol and ethanol in an alkaline medium with a current density of 3 mA/cm2 and 0.96 mA/cm2 along with good cyclic stability. Thus, this efficient flexible electrocatalyst with good stability, practicability, and repro-ducibility claims its potential applications in flexible/wearable healthcare diagnostics systems as well as in alternative energy conversion devices.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [42] A disposable and sensitive non-enzymatic glucose sensor based on a 3D-Mn-doped NiO nanoflower-modified flexible electrode
    Yang, Huisi
    Hu, Yian
    Yin, Xinxue
    Huang, Jiaqing
    Qiao, Cailin
    Hu, Zhikun
    He, Congjuan
    Huo, Danqun
    Hou, Changjun
    ANALYST, 2022, 148 (01) : 153 - 162
  • [43] Development of non-enzymatic D-glucose and ethanol electroactive electrode based on ZnO–Cu/C multifunctional nanocomposite
    W. J. Pech-Rodríguez
    J. R. Pérez-Pesina
    L. C. Ordóñez
    F. J. Rodríguez-Varela
    Journal of Materials Science: Materials in Electronics, 2023, 34
  • [44] A Non-Enzymatic Glucose Sensor Based on Ni/MnO2 Nanocomposite Modified Glassy Carbon Electrode
    Wang, Yan
    Bai, Wushuang
    Nie, Fei
    Zheng, Jianbin
    ELECTROANALYSIS, 2015, 27 (10) : 2399 - 2405
  • [45] Fabrication of highly sensitive non-enzymatic sensor based on Pt/PVF modified Pt electrode for detection of glucose
    Shveta Malhotra
    Yijun Tang
    Pradeep K. Varshney
    Journal of the Iranian Chemical Society, 2020, 17 : 521 - 531
  • [46] Fabrication of highly sensitive non-enzymatic sensor based on Pt/PVF modified Pt electrode for detection of glucose
    Malhotra, Shveta
    Tang, Yijun
    Varshney, Pradeep K.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (03) : 521 - 531
  • [47] Non-enzymatic glucose sensor based on facial hydrothermal synthesized NiO nanosheets loaded on glassy carbon electrode
    Wang, Shutao
    Wang, Cong
    Wei, Guijuan
    Xiao, Huaqing
    An, Ning
    Zhou, Yan
    An, Changhua
    Zhang, Jun
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2016, 509 : 252 - 258
  • [48] A non-enzymatic flexible and wearable sensor based on thermal transfer printing technology for continuous glucose detection in sweat
    Liang, Xinshuo
    Zhang, Shuai
    Meng, Shuo
    Tan, Renjie
    Zhang, Ke
    Hu, Jinlian
    MICROCHEMICAL JOURNAL, 2024, 207
  • [49] Pt/MXene-Based Flexible Wearable Non-Enzymatic Electrochemical Sensor for Continuous Glucose Detection in Sweat
    Li, Quan-Fu
    Chen, Xu
    Wang, Hai
    Liu, Ming
    Peng, Hui-Ling
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (10) : 13290 - 13298
  • [50] Effect of nano-composite on polyvinyl alcohol-based proton conducting membrane for direct methanol fuel cell applications
    P. Bahavan Palani
    R. Kannan
    S. Rajashabala
    S. Rajendran
    G. Velraj
    Ionics, 2015, 21 : 507 - 513