Quantitative Retrieval of Coherent Transfer Function via Fourier Ptychographic Microscopy

被引:0
|
作者
Chen Jiaming [1 ,2 ]
Pan An [1 ,2 ]
Wang Aiye [1 ,2 ]
Ma Caiwen [2 ,3 ]
Yao Baoli [1 ,2 ]
机构
[1] Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transient Opt & Photon, Xian 710119, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100094, Peoples R China
[3] CAS Key Lab Space Precis Measurement Technol, Xian 710119, Peoples R China
基金
中国国家自然科学基金;
关键词
Coherent transfer function; Fourier ptychographic microscopy; Computational optical imaging; Quantitative phase retrieval; PHASE RETRIEVAL; IMAGING-SYSTEM; WIDE-FIELD; TOMOGRAPHY; ALGORITHM;
D O I
10.3788/gzxb20235209.0911001
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The performance of an optical imaging system is typically characterized by the intensity Point Spread Function (PSF) or Optical Transfer Function (OTF). But the Coherent Transfer Function (CTF) is better for describing the coherent optical imaging system. Though the CTF characterizes the complex amplitude transfer properties of the light field, it is hard to measure compared with PSF. Fourier Ptychographic Microscopy (FPM) is a promising computational technique that can obtain both complex amplitude information of an object and the CTF of coherent imaging system, which provides a way to retrieve the CTF. FPM, combining the concept of aperture synthesis and phase retrieval, is a recently developed imaging technique that allows the reconstruction of high-resolution complex images with an extended field of view. By acquiring a series of low-resolution brightfield and darkfield images under inclined illumination and stitching them together in the Fourier domain, FPM can break through the frequency limit of the employed objective determined by its numerical aperture. Consequently, the space-bandwidth product of the optical imaging system can be effectively increased without precise mechanical scanning. The flexibility with low-cost hardware requirements makes FPM a powerful tool particularly potential for imaging biomedical samples in the field of digital pathology. Although many advanced FPM techniques have been proposed to achieve higher data acquisition efficiency and recovery accuracy in the past few years, little is known about the precision, stability, and requirements of the CTF, especially when there are inevitable system errors. If FPM can retrieve high-precision CTF, it will provide a new means for CTF calibration. Therefore, this thesis mainly studies the acquisition of CTF with high precision, stability and efficiency via FPM. In this paper, we investigate the reconstruction quality of the CTF under different system errors with different targeted algorithms and find that the reconstructions of CTF is more robust than the reconstructions of object. In addition, under the condition of good recovery of object function, different objective algorithms can also recover basically the same CTF. Therefore, the CTF recovered by FPM algorithm can be used to quantitatively characterize coherent optical systems. Based on this, we report a sub-region translation method named ST-FPM, which is used in Fourier ptychographic microscopy imaging. Based on the basic assumption that the aberration of adjacent local fields is basically unchanged, asymmetric spatial information is introduced to eliminate the grid noise caused by periodic illumination, which improves the recovery accuracy of CTF and accelerates the convergence speed of CTF reconstruction in limited images. The recovered CTF is deconvolved with incoherent images. And the contrast is additionally improved compared with the traditional FPM. In addition, this method can realize image refocusing without the prior information of defocus. In addition, we study the spatial and frequency domain data redundancy of Fourier ptychographic microscopy to recover the coherent transfer function, and find that at least about 40% spectral overlap rate is needed to accurately reconstruct the coherent transfer function, which is 10% higher than that without aberration. And at least 25 original low-resolution images are needed for the stability of coherent transfer function. Finally, we discuss the necessary conditions for stable CTF reconstruction, and verify the conclusion in simulation and experiment.
引用
收藏
页数:13
相关论文
共 37 条
  • [11] Incubator embedded cell culture imaging system (EmSight) based on Fourier ptychographic microscopy
    Kim, Jinho
    Henley, Beverley M.
    Kim, Charlene H.
    Lester, Henry A.
    Yang, Changhuei
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (08): : 3097 - 3110
  • [12] Fourier ptychography: current applications and future promises
    Konda, Pavan Chandra
    Loetgering, Lars
    Zhou, Kevin C.
    Xu, Shiqi
    Harvey, Andrew R.
    Horstmeyer, Roarke
    [J]. OPTICS EXPRESS, 2020, 28 (07) : 9603 - 9630
  • [13] Embedded pupil function recovery for Fourier ptychographic microscopy
    Ou, Xiaoze
    Zheng, Guoan
    Yang, Changhuei
    [J]. OPTICS EXPRESS, 2014, 22 (05): : 4960 - 4972
  • [14] PAN A, 2019, Frontiers in Optics + Laser Science APS/DLS
  • [15] High throughput Full color Fourier Ptychographic Microscopy for the Next Generation of Digital Pathologic Imager and Analyser (Invited)
    Pan An
    Gao Yuting
    Wang Aiye
    Gao Huiqin
    Ma Caiwen
    Yao Baoli
    [J]. ACTA PHOTONICA SINICA, 2022, 51 (07)
  • [16] High-resolution and large field-of-view Fourier ptychographic microscopy and its applications in biomedicine
    Pan, An
    Zuo, Chao
    Yao, Baoli
    [J]. REPORTS ON PROGRESS IN PHYSICS, 2020, 83 (09)
  • [17] Linear space-variant optical cryptosystem via Fourier ptychography
    Pan, An
    Wen, Kai
    Yao, Baoli
    [J]. OPTICS LETTERS, 2019, 44 (08) : 2032 - 2035
  • [18] Three-dimensional space optimization for near-field ptychography
    Pan, An
    Yao, Baoli
    [J]. OPTICS EXPRESS, 2019, 27 (04) : 5433 - 5446
  • [19] Adaptive-window angular spectrum algorithm for near-field ptychography
    Pan, An
    Zhou, Meiling
    Zhang, Yan
    Min, Junwei
    Lei, Ming
    Yao, Baolai
    [J]. OPTICS COMMUNICATIONS, 2019, 430 : 73 - 82
  • [20] System calibration method for Fourier ptychographic microscopy
    Pan, An
    Zhang, Yan
    Zhao, Tianyu
    Wang, Zhaojun
    Dan, Dan
    Lei, Ming
    Yao, Baoli
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (09)