Endpoint estimation using a measurement sensor for freeze-drying process control

被引:2
|
作者
Jeyapradhap, T. [1 ]
Srinivasan, G. [2 ]
Raja, B. [1 ]
机构
[1] Indian Inst Informat Technol, Dept Mech Engn, Design & Mfg Kancheepuram, IIITDM Kancheepuram, Chennai, Tamil Nadu, India
[2] Tezpur Univ, Sch Engn, Dept Design, Tezpur, Assam, India
关键词
Freeze-drying; Endpoint; Measurement device; Drying process; Sublimation; Sensor; MANOMETRIC TEMPERATURE-MEASUREMENT; DESIGN;
D O I
10.1016/j.tsep.2023.101848
中图分类号
O414.1 [热力学];
学科分类号
摘要
The drying stage in a freeze-drying process plays a significant role in determining product quality. Determination of the endpoint of the drying stage is a tedious process. Thus, a measurement device is designed, developed, and tested to determine the endpoint of the drying process in this work. The experiments were conducted during freeze-drying of skimmed milk using a pre-calibrated velocity sensor connected with an Arduino unit. The developed sensor is placed between the product chamber and condensing unit. The flow rate of the water vapour sublimated and desorbed from the product is measured using the sensor. The measured parameters determine the amount of product sublimated and desorbed, water content removed, and mass transfer coefficient. The drying process's endpoint is determined based on the amount of water vapour sublimated and desorbed during the drying process. The initial stage of the drying process exhibited a falling rate period, where unbound water molecules on the surface started to sublimate faster, resulting in higher velocity. The ice layers formed in the condensing unit are drained after the experiments and compared with the values determined from the sensor during the drying process. The average deviation was reported to be minimal (4.4%). Thus, the developed measurement device can be implemented to determine the endpoint during a freeze-drying process with better accuracy and sensitivity. Further, the developed sensor is economical and can be easily installed without significant modifications in the freeze-drying unit.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Determination of End Point of Primary Drying in Freeze-Drying Process Control
    Patel, Sajal M.
    Doen, Takayuki
    Pikal, Michael J.
    AAPS PHARMSCITECH, 2010, 11 (01): : 73 - 84
  • [2] Automatic control of a freeze-drying process: Detection of the end point of primary drying
    Pisano, Roberto
    DRYING TECHNOLOGY, 2022, 40 (01) : 140 - 157
  • [3] Process intensification and process control in freeze-drying
    Barresi, A. A.
    Pisano, R.
    IDS'2018: 21ST INTERNATIONAL DRYING SYMPOSIUM, 2018, : 9 - 16
  • [4] Determination of End Point of Primary Drying in Freeze-Drying Process Control
    Sajal M. Patel
    Takayuki Doen
    Michael J. Pikal
    AAPS PharmSciTech, 2010, 11 : 73 - 84
  • [5] Emerging PAT for Freeze-Drying Processes for Advanced Process Control
    Juckers, Alex
    Knerr, Petra
    Harms, Frank
    Strube, Jochen
    PROCESSES, 2022, 10 (10)
  • [6] Investigation of freeze-drying sublimation rates using a freeze-drying microbalance technique
    Xiang, J
    Hey, JM
    Liedtke, V
    Wang, DQ
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 279 (1-2) : 95 - 105
  • [7] Freeze-Drying Cycle Optimization Using Model Predictive Control Techniques
    Pisano, Roberto
    Fissore, Davide
    Barresi, Antonello A.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (12) : 7363 - 7379
  • [8] Freeze-drying of nanocapsules: Impact of annealing on the drying process
    Abdelwahed, Wassim
    Degobert, Ghania
    Fessi, Hatem
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2006, 324 (01) : 74 - 82
  • [9] On the use of temperature measurement to monitor a freeze-drying process for pharmaceuticals
    Fissore, Davide
    Pisano, Roberto
    Barresi, Antonello A.
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1276 - 1281
  • [10] Process Analytical Technologies (PAT) in freeze-drying of parenteral products
    Patel, Sajal Manubhai
    Pikal, Michael
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2009, 14 (06) : 567 - 587