Euler-Euler CFD simulation of high velocity gas injection at pool scrubbing conditions

被引:19
作者
Li, Shiwang [1 ]
Apanasevich, Pavel [2 ]
Lucas, Dirk [1 ]
Liao, Yixiang [1 ]
机构
[1] Helmholtz Zent Dresden Rossendorf, Inst Fluid Dynam, Bautzner Landstr 400, D-01328 Dresden, Germany
[2] Hydrograv GmbH, August Bebel Str 48, D-01219 Dresden, Germany
关键词
decontamination factor; hydrodynamics; OpenFOAM; pool scrubbing; two-fluid model; TURBULENCE MODEL; INTERFACIAL AREA; BUBBLE-COLUMNS; 2-FLUID MODEL; FLOWS; AEROSOL; COEFFICIENT;
D O I
10.1007/s42757-022-0149-3
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pressure relief by blowdown is one of the most important measures to prevent excessive pressures in the primary circuit or containment in severe nuclear accidents. Pool scrubbing can significantly reduce the release of radioactive materials, e.g., aerosols, to the environment during the pressure relief. The decontamination factor indicating the particle retention efficiency depends, among other factors, on the hydrodynamic conditions of the gas-liquid two-phase flow inside the pool. In the present work, the hydrodynamics in two typical pool scrubbing experiments is investigated with the two-fluid model, and the influence of some key factors including bubble diameter, nozzle submergence as well as interaction models are analysed. One case is a rectangular pool and the other is a cylindrical column, and their injection Weber number is around 2x10(3) and 4x10(5), respectively. The numerical results show that as the distance from the nozzle exit increases, the void fraction and velocity field expand from the central region, where the nozzle is located, to the whole cross section. The profile and its development depends largely on the bubble size and the interaction force model. It reveals that in the monodisperse simulation, the tuning of bubble diameter is necessary for achieving good agreement, although it is difficult for high velocity gas injection. More information is required to properly describe the bubble size distribution as well as its evolution in pool scrubbing conditions. Furthermore, the experimental data show clear drag reduction in the bubble swarm generated by the gas jet, and the mechanism and model improvement possibilities need to be investigated.
引用
收藏
页码:365 / 380
页数:16
相关论文
共 56 条
[1]   Bubble dynamics with aerosol during pool scrubbing [J].
Abe, Yutaka ;
Fujiwara, Kota ;
Saito, Shimpei ;
Yuasa, Tomohisa ;
Kaneko, Akiko .
NUCLEAR ENGINEERING AND DESIGN, 2018, 337 :96-107
[2]   BUBBLE SIZE, INTERFACIAL AREA, AND LIQUID-PHASE MASS-TRANSFER COEFFICIENT IN BUBBLE COLUMNS [J].
AKITA, K ;
YOSHIDA, F .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1974, 13 (01) :84-91
[3]   Eulerian-Eulerian multi-phase RPI modeling of turbulent forced convective of boiling flow inside the tube with porous medium [J].
Azadbakhti, Reza ;
Pourfattah, Farzad ;
Ahmadi, Abolfazl ;
Akbari, Omid Ali ;
Toghraie, Davood .
INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2020, 30 (05) :2739-2757
[4]  
Bicer E., 2021, T KOR NUCL SOC VIRT
[5]  
Burns A.D., 2004, Fifth Int. Conf. Multiph. Flow, P1
[6]  
Drew D.A., 1998, Theory of Multicomponent Fluids
[7]   Complex bubble deformation and break-up dynamics studies using interface capturing approach [J].
Fan, Yuqiao ;
Fang, Jun ;
Bolotnov, Igor .
EXPERIMENTAL AND COMPUTATIONAL MULTIPHASE FLOW, 2021, 3 (03) :139-151
[8]   A fast Eulerian method for disperse two-phase flow [J].
Ferry, J ;
Balachandar, S .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2001, 27 (07) :1199-1226
[9]   Eulerian and Lagrangian approaches for predicting the behaviour of discrete particles in turbulent flows [J].
Gouesbet, G ;
Berlemont, A .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 1999, 25 (02) :133-159
[10]   Investigation on Aerosol Pool Scrubbing Model During Severe Accidents [J].
He, L. W. ;
Li, Y. X. ;
Zhou, Y. ;
Chen, S. ;
Tong, L. L. ;
Cao, X. W. .
FRONTIERS IN ENERGY RESEARCH, 2021, 9