Allocation of Spinning Reserves in Autonomous Grids Considering Frequency Stability Constraints and Short-Term Solar Power Variations

被引:6
作者
Alves, Erick F. [1 ]
Polleux, Louis [2 ,3 ]
Guerassimoff, Gilles [2 ]
Korpas, Magnus [1 ]
Tedeschi, Elisabetta [1 ,4 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Elect Power Engn, N-7034 Trondheim, Norway
[2] Mines Paris PSL, Ctr Appl Math, F-06904 Sophia Antipolis, France
[3] TotalEnergies, Res & Dev, F-92400 Courbevoie, France
[4] Univ Trento, Dept Ind Engn, I-38193 Trento, Italy
关键词
Generators; Power system stability; Optimization; Mathematical models; Costs; Batteries; Time-frequency analysis; Renewable energy sources; Solar power; Autonomous power systems; renewable energy; frequency stability; unit commitment; linear optimization; solar variability; MANAGEMENT;
D O I
10.1109/ACCESS.2023.3261805
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Low-inertia, isolated power systems face the problem of resiliency to active power variations. The integration of variable renewable energy sources, such as wind and solar photovoltaic, pushes the boundaries of this issue further. Higher shares of renewables requires better evaluations of electrical system stability, to avoid severe safety and economic consequences. Accounting for frequency stability requirements and allocating proper spinning reserves, therefore becomes a topic of pivotal importance in the planning and operational management of power systems. In this paper, dynamic frequency constraints are proposed to ensure resiliency during short-term power variations due to, for example, wind gusts or cloud passage. The use of the proposed constraints is exemplified in a case study, the constraints being integrated into a mixed-integer linear programming algorithm for sizing the optimal capacities of solar photovoltaic and battery energy storage resources in an isolated industrial plant. Outcomes of this case study show that reductions in the levelized cost of energy and carbon emissions can be overestimated by 8.0% and 10.8% respectively, where frequency constraints are neglected. The proposed optimal sizing is validated using time-domain simulations of the case study. The results indicate that this optimal system is frequency stable under the worst-case contingency.
引用
收藏
页码:29896 / 29908
页数:13
相关论文
共 49 条
[1]  
Alves E. F., 2010, 2010 IEEE/PES Transmission & Distribution Conference & Exposition: Latin America (T&D-LA 2010), P298, DOI 10.1109/TDC-LA.2010.5762897
[2]   Sufficient Conditions for Robust Frequency Stability of AC Power Systems [J].
Alves, Erick ;
Bergna-Diaz, Gilbert ;
Brandao, Danilo ;
Tedeschi, Elisabetta .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (03) :2684-2692
[3]  
Alves Erick F, 2023, Zenodo, DOI 10.5281/ZENODO.6334799
[4]   Sizing of Hybrid Energy Storage Systems for Inertial and Primary Frequency Control [J].
Alves, Erick Fernando ;
Mota, Daniel dos Santos ;
Tedeschi, Elisabetta .
FRONTIERS IN ENERGY RESEARCH, 2021, 9
[5]  
Anglani N., 2020, PROC IEEE INT C ENV, P1
[6]  
[Anonymous], 2012, PV PERFORMANCE MODEL
[7]  
[Anonymous], 2017, GUID EL TRANSM SYST
[8]  
[Anonymous], 2019, 618922019 IEC
[9]  
[Anonymous], 2019, 5054912019 NEK EN
[10]  
[Anonymous], 2019, 5054922019 NEK EN