A high-throughput fully automatic biosensing platform for efficient COVID-19 detection

被引:12
作者
Rong, Guoguang [1 ,2 ,3 ]
Zheng, Yuqiao [1 ,2 ,3 ]
Li, Xiangqing [2 ,3 ]
Guo, Mengzhun [4 ,5 ,6 ]
Su, Yi [1 ,2 ,3 ]
Bian, Sumin [1 ,2 ,3 ]
Dang, Bobo [4 ,5 ,6 ]
Chen, Yin [7 ]
Zhang, Yanjun [7 ]
Shen, Linhai [8 ]
Jin, Hui [8 ]
Yan, Renhong [4 ,5 ]
Wen, Liaoyong [2 ,3 ]
Zhu, Peixi [9 ]
Sawan, Mohamad [1 ,2 ,3 ]
机构
[1] Westlake Univ, Sch Engn, CenBRAIN Neurotech, 600 Dunyu Rd, Hangzhou 310030, Zhejiang, Peoples R China
[2] Westlake Univ, Sch Engn, 600 Dunyu Rd, Hangzhou 310030, Zhejiang, Peoples R China
[3] Westlake Inst Adv Study, Inst Adv Study, Hangzhou 310024, Zhejiang, Peoples R China
[4] Westlake Univ, Sch Life Sci, Key Lab Struct Biol Zhejiang Prov, Hangzhou 310030, Zhejiang, Peoples R China
[5] Westlake Lab Life Sci & Biomed, Ctr Infect Dis Res, Hangzhou 310030, Zhejiang, Peoples R China
[6] Westlake Inst Adv Study, Inst Biol, Hangzhou 310030, Zhejiang, Peoples R China
[7] Zhejiang Prov Ctr Dis Control & Prevent, 3399 Binsheng Rd, Hangzhou 310051, Zhejiang, Peoples R China
[8] Hangzhou Ctr Dis Control & Prevent, 568 Mingshi Rd, Hangzhou 310021, Zhejiang, Peoples R China
[9] Zhejiang Univ Technol, Coll Pharmaceut Sci, Hangzhou 310014, Zhejiang, Peoples R China
关键词
Biosensor; Localized surface plasmon resonance (LSPR); SARS-CoV-2; COVID-19; Automatic detection; High throughput; SURFACE-PLASMON RESONANCE; DIAGNOSIS; SARS-COV-2; SIZE;
D O I
10.1016/j.bios.2022.114861
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We propose a label-free biosensor based on a porous silicon resonant microcavity and localized surface plasmon resonance. The biosensor detects SARS-CoV-2 antigen based on engineered trimeric angiotensin converting enzyme-2 binding protein, which is conserved across different variants. Robotic arms run the detection process including sample loading, incubation, sensor surface rinsing, and optical measurements using a portable spec-trometer. Both the biosensor and the optical measurement system are readily scalable to accommodate testing a wide range of sample numbers. The limit of detection is 100 TCID50/ml. The detection time is 5 min, and the throughput of one single robotic site is up to 384 specimens in 30 min. The measurement interface requires little training, has standard operation, and therefore is suitable for widespread use in rapid and onsite COVID-19 screening or surveillance.
引用
收藏
页数:9
相关论文
共 52 条
[1]   Electrochemical immunosensor modified with self-assembled monolayer of 11-mercaptoundecanoic acid on gold electrodes for detection of benzo[a]pyrene in water [J].
Ahmad, Azrilawani ;
Moore, Eric .
ANALYST, 2012, 137 (24) :5839-5844
[2]   Rapid Detection of SARS-CoV-2 by Low Volume Real-Time Single Tube Reverse Transcription Recombinase Polymerase Amplification Using an Exo Probe with an Internally Linked Quencher (Exo-IQ) [J].
Behrmann, Ole ;
Bachmann, Iris ;
Spiegel, Martin ;
Schramm, Marina ;
Abd El Wahed, Ahmed ;
Dobler, Gerhard ;
Dame, Gregory ;
Hufert, Frank T. .
CLINICAL CHEMISTRY, 2020, 66 (08) :1047-1054
[3]   Gold nanoparticle based plasmonic sensing for the detection of SARS-CoV-2 nucleocapsid proteins [J].
Behrouzi, Kamyar ;
Lin, Liwei .
BIOSENSORS & BIOELECTRONICS, 2022, 195
[4]   A multi-target lateral flow immunoassay enabling the specific and sensitive detection of total antibodies to SARS COV-2 [J].
Cavalera, Simone ;
Colitti, Barbara ;
Rosati, Sergio ;
Ferrara, Gianmarco ;
Bertolotti, Luigi ;
Nogarol, Chiara ;
Guiotto, Cristina ;
Cagnazzo, Celeste ;
Denina, Marco ;
Fagioli, Franca ;
Di Nardo, Fabio ;
Chiarello, Matteo ;
Baggiani, Claudio ;
Anfossi, Laura .
TALANTA, 2021, 223
[5]   Urgent need of rapid tests for SARS CoV-2 antigen detection: Evaluation of the SD-Biosensor antigen test for SARS-CoV-2 [J].
Cerutti, Francesco ;
Burdino, Elisa ;
Milia, Maria Grazia ;
Allice, Tiziano ;
Gregori, Gabriella ;
Bruzzone, Bianca ;
Ghisetti, Valeria .
JOURNAL OF CLINICAL VIROLOGY, 2020, 132
[6]   A neutralizing human antibody binds to the N-terminal domain of the Spike protein of SARS-CoV-2 [J].
Chi, Xiangyang ;
Yan, Renhong ;
Zhang, Jun ;
Zhang, Guanying ;
Zhang, Yuanyuan ;
Hao, Meng ;
Zhang, Zhe ;
Fan, Pengfei ;
Dong, Yunzhu ;
Yang, Yilong ;
Chen, Zhengshan ;
Guo, Yingying ;
Zhang, Jinlong ;
Li, Yaning ;
Song, Xiaohong ;
Chen, Yi ;
Xia, Lu ;
Fu, Ling ;
Hou, Lihua ;
Xu, Junjie ;
Yu, Changming ;
Li, Jianmin ;
Zhou, Qiang ;
Chen, Wei .
SCIENCE, 2020, 369 (6504) :650-+
[7]   Localized surface plasmon resonance based biosensing [J].
Csaki, Andrea ;
Stranik, Ondrej ;
Fritzsche, Wolfgang .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2018, 18 (03) :279-296
[8]   Rapid and sensitive detection of SARS-CoV-2 antibodies by biolayer interferometry [J].
Dzimianski, John V. ;
Lorig-Roach, Nicholas ;
O'Rourke, Sara M. ;
Alexander, David L. ;
Kimmey, Jacqueline M. ;
DuBois, Rebecca M. .
SCIENTIFIC REPORTS, 2020, 10 (01)
[9]   Development of a Low-Cost Cotton-Tipped Electrochemical Immunosensor for the Detection of SARS-CoV-2 [J].
Eissa, Shimaa ;
Zourob, Mohammed .
ANALYTICAL CHEMISTRY, 2021, 93 (03) :1826-1833
[10]  
Evangelista S., 2020, COVID 19 USING WASTE