Validation of the distal filling ratio in uncemented convertible short-stem shoulder arthroplasty

被引:2
作者
Raiss, Patric [1 ]
Wittmann, Thomas [1 ]
Blakeney, William [2 ]
Urvoy, Manuel [3 ]
Walch, Gilles [4 ]
机构
[1] OCM Orthopad Chirurg Munchen Clin, Steinerstr 6, D-81369 Munich, Germany
[2] Royal Perth Hosp, Dept Orthopaed Surg, Victoria Sq, Perth, WA 6000, Australia
[3] IMASCAP, 145 Rue Rene Descartes, F-29280 Plouzane, France
[4] Ctr Orthoped Santy, 24 Ave Paul Santy, F-69008 Lyon, France
关键词
Shoulder arthroplasty; Shoulder replacement; Stress shielding; Uncemented stem; 3D planning;
D O I
10.1007/s00402-022-04389-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Radiographic stress shielding is a common finding in uncemented convertible short-stem shoulder arthroplasty (UCSSSA). The distal filling ratio (DFR) has been described as a predictor for the occurrence of stress shielding. A DFR > 70% was mentioned as a risk factor for the occurrence of stress shielding for some UCSSSA. However, measurements were only performed on conventional radiographs and no validation exists for 3D automated planning tools. Methods DFR was manually measured on postoperative true ap radiographs of 76 shoulder arthroplasties using a standardized protocol and were compared to preoperative CT scans with an automated calculation of the DFR after virtual implantation of the stem. Results The mean DFR measured on X-rays was 75.9% (SD = 8.7; 95% CI = 74-78) vs. 78.9% (SD = 9.1; 95% CI = 76.8-83) automatically measured on CT scans. This difference was significant (p < 0.001). In 7 out of 76 cases (9%) the difference between manual measurement on radiographs and computerized measurement on CT scans was > 10%. Conclusion Manual measurement of the DFR is underestimated on conventional radiographs compared to automated calculation on CT scans be a mean of 3%. Therefore, automated measurement of the DFR on CT scans seems to be beneficial, especially in cases with osteopenic cortices. Manual measurement of the DFR on conventional ap radiographs in cases without CT scans, however, is still a viable alternative.
引用
收藏
页码:1833 / 1839
页数:7
相关论文
共 22 条
  • [1] Short stem humeral components in reverse shoulder arthroplasty: stem alignment influences the neck-shaft angle
    Abdic, Sejla
    Athwal, George S.
    Wittmann, Thomas
    Walch, Gilles
    Raiss, Patric
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (02) : 183 - 188
  • [2] Radiographic evaluation of short-stem press-fit total shoulder arthroplasty: short-term follow-up
    Casagrande, Danielle J.
    Parks, Di L.
    Torngren, Travis
    Schrumpf, Mark A.
    Harmsen, Samuel M.
    Norris, Tom R.
    Kelly, James D., II
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (07) : 1163 - 1169
  • [3] Three-dimensional Volumetric Filling Ratio Predicts Stress Shielding in Short-stem Anatomic Total Shoulder Arthroplasty
    Celik, Haluk
    Chauhan, Aakash
    Flores-Hernandez, Cesar
    D'Lima, Darryl
    Hoenecke, Heinz
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (24) : 1047 - 1054
  • [4] Cole Elliott W, 2020, JSES Int, V4, P109, DOI 10.1016/j.jses.2019.11.002
  • [5] Stress shielding of the humerus in press-fit anatomic shoulder arthroplasty: review and recommendations for evaluation
    Denard, Patrick J.
    Raiss, Patric
    Gobezie, Reuben
    Edwards, T. Bradley
    Lederman, Evan
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (06) : 1139 - 1147
  • [6] Denard PJ, 2007, J SHOULDER ELB SURG
  • [7] Humeral Cementless Surface Replacement Arthroplasties of the Shoulder: An Experimental Investigation on Their Initial Fixation
    Jakubowitz, Eike
    Neubrech, Christine
    Raiss, Patric
    Nadorf, Jan
    Tanner, Michael C.
    Rickert, Markus
    Kasten, Philip
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (08) : 1216 - 1221
  • [8] Do short stems influence the cervico-diaphyseal angle and the medullary filling after reverse shoulder arthroplasties?
    Laedermann, Alexandre
    Chiu, Joe Chih-Hao
    Cunningham, Gregory
    Herve, Anthony
    Piotton, Sebastien
    Bothorel, Hugo
    Collin, Philippe
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (02) : 241 - 246
  • [9] Reverse shoulder arthroplasty with a cementless short metaphyseal humeral implant without a stem: clinical and radiologic outcomes in prospective 2-to 7-year follow-up study
    Levy, Ofer
    Narvani, Ali
    Hous, Nir
    Abraham, Ruben
    Relwani, Jai
    Pradhan, Riten
    Bruguera, Juan
    Sforza, Giuseppe
    Atoun, Ehud
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (08) : 1362 - 1370
  • [10] Proximal ingrowth coating decreases risk of loosening following uncemented shoulder arthroplasty using mini-stem humeral components and lesser tuberosity osteotomy
    Morwood, Michael P.
    Johnston, Peter S.
    Garrigues, Grant E.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (07) : 1246 - 1252