Combination Use of Compressed Sensing and Deep Learning for Shoulder Magnetic Resonance Imaging With Various Sequences

被引:4
作者
Shiraishi, Kaori [1 ]
Nakaura, Takeshi [1 ,5 ]
Uetani, Hiroyuki [1 ]
Nagayama, Yasunori [1 ]
Kidoh, Masafumi [1 ]
Kobayashi, Naoki [1 ]
Morita, Kosuke [2 ]
Yamahita, Yuichi [3 ]
Miyamoto, Takeshi [4 ]
Hirai, Toshinori [1 ]
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[2] Kumamoto Univ Hosp, Dept Radiol, Kumamoto, Japan
[3] Canon Med Syst Corp, Kawasaki, Japan
[4] Kumamoto Univ, Grad Sch Med Sci, Dept Orthopaedicsurg, Kumamoto, Japan
[5] Kumamoto Univ Hosp, Radiol, 1-1-1 Honjo,Chuo, Kumamoto, Kumamoto 8608556, Japan
关键词
retrospective studies; signal-to-noise ratio; shoulder; deep learning; magnetic resonance imaging; CNR; contrast-to-noise ratio; CS; compressed sensing; DLR; deep-learning-based reconstruction; FS-T2WI; fat-saturation T2-weighted images; FWHM; full width at half maximum; ROI; regions of interest; SD; standard deviation; SI; signal intensity; SNR; T1WI; T1-weighted images; T2WI; T2-weighted images; Wavelet method; wavelet-based denoising method; RECONSTRUCTION; MRI; CHOLANGIOPANCREATOGRAPHY; QUALITY;
D O I
10.1097/RCT.0000000000001418
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveFor compressed sensing (CS) to become widely used in routine magnetic resonance imaging (MRI), it is essential to improve image quality. This study aimed to evaluate the usefulness of combining CS and deep learning-based reconstruction (DLR) for various sequences in shoulder MRI.MethodsThis retrospective study included 37 consecutive patients who underwent undersampled shoulder MRIs, including T1-weighted (T1WI), T2-weighted (T2WI), and fat-saturation T2-weighted (FS-T2WI) images. Images were reconstructed using the conventional wavelet-based denoising method (wavelet method) and a combination of wavelet and DLR-based denoising methods (hybrid-DLR method) for each sequence. The signal-to-noise ratio and contrast-to-noise ratio of the bone, muscle, and fat and the full width at half maximum of the shoulder joint were compared between the 2 image types. In addition, 2 board-certified radiologists scored the image noise, contrast, sharpness, artifacts, and overall image quality of the 2 image types on a 4-point scale.ResultsThe signal-to-noise ratios and contrast-to-noise ratios of the bone, muscle, and fat in T1WI, T2WI, and FS-T2WI obtained from the hybrid-DLR method were significantly higher than those of the conventional wavelet method (P < 0.001). However, there were no significant differences in the full width at half maximum of the shoulder joint in any of the sequences (P > 0.05). Furthermore, in all sequences, the mean scores of the image noise, sharpness, artifacts, and overall image quality were significantly higher in the hybrid-DLR method than in the wavelet method (P < 0.001), but there were no significant differences in contrast among the sequences (P > 0.05).ConclusionsThe DLR denoising method can improve the image quality of CS in T1-weighted images, T2-weighted images, and fat-saturation T2-weighted images of the shoulder compared with the wavelet denoising method alone.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 19 条
[1]   DeepCDA: deep cross-domain compound-protein affinity prediction through LSTM and convolutional neural networks [J].
Abbasi, Karim ;
Razzaghi, Parvin ;
Poso, Antti ;
Amanlou, Massoud ;
Ghasemi, Jahan B. ;
Masoudi-Nejad, Ali .
BIOINFORMATICS, 2020, 36 (17) :4633-4642
[2]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[3]   Domain adversarial networks and intensity-based data augmentation for male pelvic organ segmentation in cone beam CT [J].
Brion, Eliott ;
Leger, Jean ;
Barragan-Montero, A. M. ;
Meert, Nicolas ;
Lee, John A. ;
Macq, Benoit .
COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 131
[4]   Learning a variational network for reconstruction of accelerated MRI data [J].
Hammernik, Kerstin ;
Klatzer, Teresa ;
Kobler, Erich ;
Recht, Michael P. ;
Sodickson, Daniel K. ;
Pock, Thomas ;
Knoll, Florian .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :3055-3071
[5]   Denoising of 3D magnetic resonance images with multi-channel residual learning of convolutional neural network [J].
Jiang, Dongsheng ;
Dou, Weiqiang ;
Vosters, Luc ;
Xu, Xiayu ;
Sun, Yue ;
Tan, Tao .
JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (09) :566-574
[6]   Deep Learning Based Noise Reduction for Brain MR Imaging: Tests on Phantoms and Healthy Volunteers [J].
Kidoh, Masafumi ;
Shinoda, Kensuke ;
Kitajima, Mika ;
Isogawa, Kenzo ;
Nambu, Masahito ;
Uetani, Hiroyuki ;
Morita, Kosuke ;
Nakaura, Takeshi ;
Tateishi, Machiko ;
Yamashita, Yuichi ;
Yamashita, Yasuyuki .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (03) :195-206
[7]   Sparse MRI: The application of compressed sensing for rapid MR imaging [J].
Lustig, Michael ;
Donoho, David ;
Pauly, John M. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) :1182-1195
[8]   Deep learning in radiology: An overview of the concepts and a survey of the state of the art with focus on MRI [J].
Mazurowski, Maciej A. ;
Buda, Mateusz ;
Saha, Ashirbani ;
Bashir, Mustafa R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (04) :939-954
[9]   High resolution time-of-flight MR-angiography at 7 T exploiting VERSE saturation, compressed sensing and segmentation [J].
Meixner, Christian R. ;
Liebig, Patrick ;
Speier, Peter ;
Forman, Christoph ;
Hensel, Bernhard ;
Schmidt, Manuel ;
Saake, Marc ;
Uder, Michael ;
Doerfler, Arnd ;
Heidemann, Robin M. ;
Schmitter, Sebastian ;
Nagel, Armin M. .
MAGNETIC RESONANCE IMAGING, 2019, 63 :193-204
[10]   Hybrid of Compressed Sensing and Parallel Imaging Applied to Three-dimensional Isotropic T2-weighted Turbo Spin-echo MR Imaging of the Lumbar Spine [J].
Morita, Kosuke ;
Nakaura, Takeshi ;
Maruyama, Natsuki ;
Iyama, Yuji ;
Oda, Seitaro ;
Utsunomiya, Daisuke ;
Namimoto, Tomohiro ;
Kitajima, Mika ;
Yoneyama, Masami ;
Yamashita, Yasuyuki .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (01) :48-55