Study on Axial Compression Performance of Corroded Reinforced Concrete Columns Strengthened by Concrete Canvas and Carbon Fiber Reinforced Plastic under Secondary Corrosion

被引:1
|
作者
Li, Fengge [1 ]
Chen, Chen [1 ]
Xiang, Zehui [1 ]
机构
[1] Inner Mongolia Univ Sci & Technol, Coll Civil Engn, Baotou 014010, Peoples R China
基金
中国国家自然科学基金;
关键词
concrete canvas; carbon fiber reinforced plastic; corroded concrete columns; corrosion rate; peak stress-strain model;
D O I
10.3390/buildings14030803
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the effects of concrete canvas (CC) and carbon fiber reinforced plastic (CFRP) reinforcement on the mechanical properties of corroded reinforced concrete columns (compressive strength, flexure strength, strength of extension, and so on), 42 columns in four groups were designed and axial compression experiments were carried out. For the corroded reinforced concrete columns reinforced with CC and CFRP, the effects of initial corrosion rate (5%, 10%), secondary corrosion time (15 d, 30 d), number of CC layers (0, 1), and number of CFRP layers (1, 2, 3) on the failure morphology, load carrying capacity, and ductility of concrete columns were analyzed. The test results show that the properties of the single layer CC confined specimens are improved to a certain extent, and the ductility properties are enhanced. The properties of the CC-CFRP composite constrained specimens are greatly improved, the plastic deformation ability is enhanced, and the typical ductile damage characteristics are shown. The corrosion inhibition of CC for specimens with a theoretical corrosion rate lower than 20% showed an increasing trend, and the corrosion inhibition rate ranged from 23.0% to 31.2%. CC and CFRP restrain the concrete jointly, hindering the expansion inside the concrete, and the peak strain of the joint restraint specimen itself changes greatly, while the overall peak strain of the corrosion specimen is very small under the action of the joint steel bar. Finally, according to the existing peak stress-strain model and the experimental data in this paper, a peak stress-strain model suitable for corroded reinforced concrete columns is established. The established calculation model has a high accuracy, which provides a certain theoretical basis for subsequent research.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Fire performance of aged and corroded reinforced concrete columns
    Chandra, Shashank
    Sharma, Umesh Kumar
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [42] Investigation of Axial Strengthened Reinforced Concrete Columns under Lateral Blast Loading
    Omran, Mohammad Esmaeilnia
    Mollaei, Somayeh
    SHOCK AND VIBRATION, 2017, 2017
  • [43] Experimental investigations on strengthened reinforced concrete columns under monotonic axial loading
    Sirimontree, S.
    Keawsawasvong, S.
    Thongchom, C.
    Jongvivatsakul, P.
    Noroozinejad Farsangi, E.
    International Journal of Engineering, Transactions B: Applications, 2021, 34 (05): : 1124 - 1131
  • [44] Experimental Investigations on Strengthened Reinforced Concrete Columns under Monotonic Axial Loading
    Sirimontree, S.
    Keawsawasvong, S.
    Thongchom, C.
    Jongvivatsakul, P.
    Noroozinejad Farsangi, E.
    International Journal of Engineering, Transactions A: Basics, 2021, 34 (05): : 1124 - 1131
  • [45] Experimental Investigations on Strengthened Reinforced Concrete Columns under Monotonic Axial Loading
    Sirimontree, S.
    Keawsawasvong, S.
    Thongchoma, C.
    Jongvivatsakul, P.
    Farsangi, E. Noroozinejad
    INTERNATIONAL JOURNAL OF ENGINEERING, 2021, 34 (05): : 1124 - 1131
  • [46] Axial preloading effects when reinforced concrete columns are strengthened by concrete jackets
    Vandoros, Konstantinos G.
    Dritsos, Stephanos E.
    PROGRESS IN STRUCTURAL ENGINEERING AND MATERIALS, 2006, 8 (03) : 79 - 92
  • [47] Hybrid fiber reinforced concrete-filled square stub columns under axial compression
    Guler, Soner
    Yavuz, Demet
    Aydin, Muhammet
    ENGINEERING STRUCTURES, 2019, 198
  • [48] Reinforced concrete corbels strengthened with carbon fiber reinforced plastics
    Lu, W.-Y. (luwenyao@cute.edu.tw), 1600, Techno-Press (10):
  • [49] Experimental study on reinforced concrete corroded columns under loading condition
    Rani, M. Usha
    Subramanian, K.
    BULLETIN OF ELECTROCHEMISTRY, 2006, 22 (06): : 263 - 268
  • [50] Axial compression of reinforced concrete columns strengthened by composite of prestressed plastic-steel strip and angle steel: An experimental study
    Si, Jianhui
    Wu, Linze
    Guo, Wenjing
    STRUCTURAL CONCRETE, 2021, 22 (06) : 3620 - 3629