Point spread function modeling for photoacoustic tomography - I: three-dimensional detection geometries

被引:3
作者
Zhang, Chenxi [1 ]
Tan, Zhijian [1 ,2 ]
Tian, Chao [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Engn Sci, Hefei 230026, Anhui, Peoples R China
[2] Hefei Comprehens Natl Sci Ctr, Inst Artificial Intelligence, Hefei 230088, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
DECONVOLUTION;
D O I
10.1364/OE.499039
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Photoacoustic computed tomography (PACT) has been under intensive investigation as a promising noninvasive biomedical imaging modality. Various acoustic detector arrays have been developed to achieve enhanced imaging performance. In this paper, we study the effect of the detection geometry on image quality through point spread function (PSF) modeling based on back-projection image reconstruction. Three commonly-used three-dimensional detection geometries, namely, spherical, cylindrical, and planar detector arrays, are investigated. The effect of detector bandwidth and aperture on PSF in these detection geometries is also studied. This work provides a performance evaluation tool for acoustic detector arrays used in PACT and can be helpful in the design and selection of detector arrays in practical imaging applications.
引用
收藏
页码:1063 / 1087
页数:25
相关论文
共 29 条
  • [1] Detection of ultrawide-band ultrasound pulses in optoacoustic tomography
    Andreev, VG
    Karabutov, AA
    Oraevsky, AA
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (10) : 1383 - 1390
  • [2] Biomedical photoacoustic imaging
    Beard, Paul
    [J]. INTERFACE FOCUS, 2011, 1 (04) : 602 - 631
  • [3] Chen SL, 2021, VIS COMPUT IND BIOME, V4, DOI 10.1186/s42492-021-00073-1
  • [4] Practical photoacoustic tomography: Realistic limitations and technical solutions
    Choi, Wonseok
    Oh, Donghyeon
    Kim, Chulhong
    [J]. JOURNAL OF APPLIED PHYSICS, 2020, 127 (23)
  • [5] PHOTOACOUSTIC MONOPOLE RADIATION IN 1-DIMENSION, 2-DIMENSION, AND 3-DIMENSION
    DIEBOLD, GJ
    SUN, T
    KHAN, MI
    [J]. PHYSICAL REVIEW LETTERS, 1991, 67 (24) : 3384 - 3387
  • [6] Spatial resolution in photoacoustic tomography: effects of detector size and detector bandwidth
    Haltmeier, Markus
    Zangerl, Gerhard
    [J]. INVERSE PROBLEMS, 2010, 26 (12)
  • [7] In Vivo Photoacoustic Sentinel Lymph Node Imaging Using Clinically-Approved Carbon Nanoparticles
    Liu, Songde
    Wang, Hang
    Zhang, Chenxi
    Dong, Jiangning
    Liu, Shengchun
    Xu, Ronald
    Tian, Chao
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (07) : 2033 - 2042
  • [8] Transmission-reflection optoacoustic ultrasound (TROPUS) computed tomography of small animals
    Mercep, Elena
    Herraiz, Joaquin L.
    Dean-Ben, Xose Luis
    Razansky, Daniel
    [J]. LIGHT-SCIENCE & APPLICATIONS, 2019, 8 (1)
  • [9] Photoacoustic Tomography Image Restoration With Measured Spatially Variant Point Spread Functions
    Qi, Li
    Wu, Jian
    Li, Xipan
    Zhang, Shuangyang
    Huang, Shixian
    Feng, Qianjin
    Chen, Wufan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (09) : 2318 - 2328
  • [10] Rosenthal A, 2013, CURR MED IMAGING, V9, P318