Indirect integration of a thermal-mechanical heat pump with a humidification-dehumidification desalination unit

被引:11
作者
Ghiasirad, Hamed [1 ]
Baris, Towhid Gholizadeh [1 ]
Javanfam, Farzin [2 ]
Kalkhoran, Hadi Rostamzadeh [3 ]
Skorek-Osikowska, Anna [1 ]
机构
[1] Silesian Tech Univ, Fac Energy & Environm Engn, Dept Power Engn & Turbomachinery, Ul Konarskiego 18, PL-44100 Gliwice, Poland
[2] Sahand Univ Technol, Dept Mech Engn, Sahand New Town, Tabriz, Iran
[3] Eindhoven Univ Technol, Eindhoven, Netherlands
关键词
HDH desalination; Absorption-compression refrigeration; Geothermal heat source; Steam extraction; Exergo-economics; THERMODYNAMIC ANALYSIS; PERFORMANCE ASSESSMENT; TRIGENERATION SYSTEM; WATER; DRIVEN; OPTIMIZATION; EXERGY;
D O I
10.1016/j.applthermaleng.2023.120852
中图分类号
O414.1 [热力学];
学科分类号
摘要
Many previously developed integrated desalination and heat pump cycles have been observed to consume a significant amount of direct electricity supply, raising concerns about their cost effectiveness. To address this issue, this study has modified the performance and cost metrics of the double-effect absorption heat pump cycle combined with a humidification-dehumidification desalination system in terms of configuration. The novelties of the present study are to preheat seawater for desalination utilizing the waste heat of the absorption chiller and to design a doble-effect hybrid thermal-mechanical heat pump. Thermodynamic and thermoeconomic tools were applied to the system. The proposed cooling/desalination system was found to produce 23.23% more freshwater and 47.7% more cooling than a traditional combination. As a result, the current cogeneration unit achieved an energy utilization factor (EUF) of 6.96, which is approximately 17.89% higher than the conventional configuration. Compared to the base case, optimal steam extraction showed a significant improvement of 27.23% in exergy efficiency. Regarding cost metrics, the cost of freshwater was determined to be 2.051 $/m3. As a result, the humidifier has the highest attribution to the overall exergy destruction at 8.98 kW, which represents approximately 16.5% of the total exergy destruction rate.
引用
收藏
页数:13
相关论文
共 45 条
  • [41] Feasibility investigation of a humidification-dehumidification (HDH) desalination system with thermoelectric generator operated by a salinity-gradient solar pond
    Rostamzadeh, Hadi
    Namin, Amin Shekari
    Nourani, Pejman
    Amidpour, Majid
    Ghaebi, Hadi
    [J]. DESALINATION, 2019, 462 : 1 - 18
  • [42] Performance assessment and optimization of a humidification dehumidification (HDH) system driven by absorption-compression heat pump cycle
    Rostamzadeh, Hadi
    Namin, Amin Shekari
    Ghaebi, Hadi
    Amidpour, Majid
    [J]. DESALINATION, 2018, 447 : 84 - 101
  • [43] Experimental investigation of a multi-stage humidification-dehumidification desalination system heated directly by a cylindrical Fresnel lens solar concentrator
    Wu, Gang
    Zheng, Hongfei
    Ma, Xinglong
    Kutlu, Cagri
    Su, Yuehong
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 143 : 241 - 251
  • [44] Experimental research on four-stage cross flow humidification dehumidification (HDH) solar desalination system with direct contact dehumidifiers
    Zhao, Yunsheng
    Zheng, Hongfei
    Liang, Shen
    Zhang, Nan
    Ma, Xing Long
    [J]. DESALINATION, 2019, 467 : 147 - 157
  • [45] Performance evaluation of humidification-dehumidification (HDH) desalination systems with and without heat recovery options: An experimental and theoretical investigation
    Zubair, Syed M.
    Antar, Mohamed A.
    Elmutasim, Samih M.
    Lawal, Dahiru U.
    [J]. DESALINATION, 2018, 436 : 161 - 175