Indirect integration of a thermal-mechanical heat pump with a humidification-dehumidification desalination unit

被引:11
作者
Ghiasirad, Hamed [1 ]
Baris, Towhid Gholizadeh [1 ]
Javanfam, Farzin [2 ]
Kalkhoran, Hadi Rostamzadeh [3 ]
Skorek-Osikowska, Anna [1 ]
机构
[1] Silesian Tech Univ, Fac Energy & Environm Engn, Dept Power Engn & Turbomachinery, Ul Konarskiego 18, PL-44100 Gliwice, Poland
[2] Sahand Univ Technol, Dept Mech Engn, Sahand New Town, Tabriz, Iran
[3] Eindhoven Univ Technol, Eindhoven, Netherlands
关键词
HDH desalination; Absorption-compression refrigeration; Geothermal heat source; Steam extraction; Exergo-economics; THERMODYNAMIC ANALYSIS; PERFORMANCE ASSESSMENT; TRIGENERATION SYSTEM; WATER; DRIVEN; OPTIMIZATION; EXERGY;
D O I
10.1016/j.applthermaleng.2023.120852
中图分类号
O414.1 [热力学];
学科分类号
摘要
Many previously developed integrated desalination and heat pump cycles have been observed to consume a significant amount of direct electricity supply, raising concerns about their cost effectiveness. To address this issue, this study has modified the performance and cost metrics of the double-effect absorption heat pump cycle combined with a humidification-dehumidification desalination system in terms of configuration. The novelties of the present study are to preheat seawater for desalination utilizing the waste heat of the absorption chiller and to design a doble-effect hybrid thermal-mechanical heat pump. Thermodynamic and thermoeconomic tools were applied to the system. The proposed cooling/desalination system was found to produce 23.23% more freshwater and 47.7% more cooling than a traditional combination. As a result, the current cogeneration unit achieved an energy utilization factor (EUF) of 6.96, which is approximately 17.89% higher than the conventional configuration. Compared to the base case, optimal steam extraction showed a significant improvement of 27.23% in exergy efficiency. Regarding cost metrics, the cost of freshwater was determined to be 2.051 $/m3. As a result, the humidifier has the highest attribution to the overall exergy destruction at 8.98 kW, which represents approximately 16.5% of the total exergy destruction rate.
引用
收藏
页数:13
相关论文
共 45 条
  • [11] Measurement of methane emission into environment during natural gas purging process
    Farzaneh-Gord, Mahmood
    Pahlevan-Zadeh, Mohammad Sadegh
    Ebrahimi-Moghadam, Amir
    Rastgar, Saied
    [J]. ENVIRONMENTAL POLLUTION, 2018, 242 : 2014 - 2026
  • [12] Design and construction of a LiBr-water absorption machine
    Florides, GA
    Kalogirou, SA
    Tassou, SA
    Wrobel, LC
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (15) : 2483 - 2508
  • [13] Ghiasirad H, 2020, INTEGRATION CLEAN SU, P103, DOI [10.1007/978-3-030-42420-6_6, DOI 10.1007/978-3-030-42420-6_6]
  • [14] Ghiasirad H, 2020, INTEGRATION CLEAN SU, P83
  • [15] Thermoeconomic assessment of a geothermal based combined cooling, heating, and power system, integrated with a humidification-dehumidification desalination unit and an absorption heat transformer
    Ghiasirad, Hamed
    Asgari, Nima
    Saray, Rahim Khoshbakhti
    Mirmasoumi, Siamak
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 235 (235)
  • [16] Exergoeconomic optimization of a new trigeneration system driven by biogas for power, cooling, and freshwater production
    Gholizadeh, Towhid
    Vajdi, Mohammad
    Rostamzadeh, Hadi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [17] A new trigeneration system for power, cooling, and freshwater production driven by a flash-binary geothermal heat source
    Gholizadeh, Towhid
    Vajdi, Mohammad
    Rostamzadeh, Hadi
    [J]. RENEWABLE ENERGY, 2020, 148 (148) : 31 - 43
  • [18] Freshwater and cooling production via integration of an ethane ejector expander transcritical refrigeration cycle and a humidification-dehumidification unit
    Gholizadeh, Towhid
    Vajdi, Mohammad
    Rostamzadeh, Hadi
    [J]. DESALINATION, 2020, 477
  • [19] Herold K.E., 2016, ABSORPT CHILL HEAT P, DOI [10.1201/B19625, DOI 10.1201/B19625]
  • [20] Experimental Study of a Thermoelectric Air Duct Dehumidification System for Tropical Climate
    Irshad, Kashif
    Almalawi, Abdulmohsen
    Habib, Khairul
    Zahir, Md Hasan
    Ali, Amjad
    Islam, Saiful
    Saha, Bidyut Baran
    [J]. HEAT TRANSFER ENGINEERING, 2021, 42 (13-14) : 1159 - 1171