Temperature Imposed Sensitivity Issues of Hetero-TFET Based pH Sensor

被引:12
作者
Bhattacharyya, Amit [1 ]
De, Debashis
Chanda, Manash [2 ]
机构
[1] Haldia Inst Technol, Dept Elect & Commun Engn, Haldia 721657, West Bengal, India
[2] Meghnad Saha Inst Technol, Dept Elect & Commun Engn, Kolkata 700150, India
关键词
Tunnel FET; hetero-structure; electrolyte; pH sensor; Nernstian limit; temperature and temporal drift; sensitivity; PARTIAL HYBRIDIZATION; TUNNEL FET; PERFORMANCE; TRANSISTOR;
D O I
10.1109/TNB.2022.3202242
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An underlapped hetero-structure electrolyte Bio-TFET for potential of hydrogen (pH) sensing has been presented in this article. Intersection charge density (D-it) near the substrate-oxide junction can be employed to represent pH value within the simulation. A feasible fabrication scheme for the proposed model is specified here. A detailed simulation is performed with an ATLAS device simulator to examine the efficiency of the projected sensor. The impact of pH alterations on device features akin to the drain current (I-DS), threshold potential (V-TH), sensitivity regarding voltage (S-V), and current (S-I) is examined. The effect of phosphate-buffered saline (PBS) concentrations on the pH buffer are also scrutinized. Moreover, the impact of the reference voltage and current (V-Ref and I-Ref), and channel doping concentration (N-CH) over S-V and S-I is analyzed methodically. Here, SV attains similar to 100 mV/pH, which is superior to the Nernstian limit (59 mV/pH) and S-I enhances nearly ten times per pH variation. Benchmarking is included to provide a quantitative assessment of the proposed model with the published literature. The impact of temperature on pH buffer, IDS, temporal drift parameters and sensitivities have been emphasized. Finally, the temperature-immunity aspect of the proposed Bio-HTFET based pH sensor is highlighted by comparing sensitivity parameter among state-of-the-art literature. Hence, the recommended pH sensor can be utilized as an outstanding substitute for the succeeding generation of biosensor applications.
引用
收藏
页码:438 / 446
页数:9
相关论文
共 34 条
[1]   A pH sensor with a double-gate silicon nanowire field-effect transistor [J].
Ahn, Jae-Hyuk ;
Kim, Jee-Yeon ;
Seol, Myeong-Lok ;
Baek, David J. ;
Guo, Zheng ;
Kim, Chang-Hoon ;
Choi, Sung-Jin ;
Choi, Yang-Kyu .
APPLIED PHYSICS LETTERS, 2013, 102 (08)
[2]   Novel junctionless electrolyte-insulator-semiconductor field-effect transistor (JL EISFET) and its application as pH/biosensor [J].
Ajay ;
Narang, Rakhi ;
Saxena, Manoj ;
Gupta, Mridula .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (08) :3149-3159
[3]   Analytical Model of pH sensing Characteristics of Junctionless Silicon on Insulator ISFET [J].
Ajay ;
Narang, Rakhi ;
Saxena, Manoj ;
Gupta, Mridula .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2017, 64 (04) :1742-1750
[4]  
[Anonymous], 2016, ATLAS Device Simulation Software
[5]   A TCAD-Based Methodology to Model the Site-Binding Charge at ISFET/Electrolyte Interfaces [J].
Bandiziol, Andrea ;
Palestri, Pierpaolo ;
Pittino, Federico ;
Esseni, David ;
Selmi, Luca .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2015, 62 (10) :3379-3386
[6]   Modeling and simulation of temperature drift for ISFET-based pH sensor and its compensation through machine learning techniques [J].
Bhardwaj, Rishabh ;
Sinha, Soumendu ;
Sahu, Nishad ;
Majumder, Sagnik ;
Narang, Pratik ;
Mukhiya, Ravindra .
INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2019, 47 (06) :954-970
[7]   Sensitivity Measurement for Bio-TFET Considering Repulsive Steric Effects With Better Accuracy [J].
Bhattacharyya, Amit ;
De, Debashis ;
Chanda, Manash .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2022, 21 :100-109
[8]   Analysis of Noise-Immune Dopingless Heterojunction Bio-TFET Considering Partial Hybridization Issue [J].
Bhattacharyya, Amit ;
Chanda, Manash ;
De Debashis .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2020, 19 (769-777) :769-777
[9]   Analysis of Partial Hybridization and Probe Positioning on Sensitivity of a Dielectric Modulated Junctionless Label Free Biosensor [J].
Bhattacharyya, Amit ;
Chanda, Manash ;
De, Debashis .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2020, 19 :719-727
[10]   Performance Assessment of New Dual-Pocket Vertical Heterostructure Tunnel FET-Based Biosensor Considering Steric Hindrance Issue [J].
Bhattacharyya, Amit ;
Chanda, Manash ;
De, Debashis .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2019, 66 (09) :3988-3993