Validity and Reliability of the Kinvent Handheld Dynamometer in the Athletic Shoulder Test

被引:8
|
作者
Olds, Margie [1 ,2 ]
McLaine, Sally [3 ]
Magni, Nico [4 ]
机构
[1] Flawless Mot Ltd, Auckland, New Zealand
[2] Univ Otago, Dept Physiotherapy, Dunedin, New Zealand
[3] Univ Tasmania, Sch Hlth Sci, Physiotas Launceston, Hobart, Tas, Australia
[4] Auckland Univ Technol, Sch Clin Sci, Dept Physiotherapy, Auckland, New Zealand
关键词
strength assessment; torque; force; return to sport; RUGBY UNION; INJURIES;
D O I
10.1123/jsr.2022-0444
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Long-lever shoulder strength tests may aid clinical decision-making regarding return to sport after a shoulder injury. The Athletic Shoulder Test (AST) was developed to measure force production in 3 positions of shoulder abduction (90 degrees, 135 degrees, and 180 degrees) using force plates. However, handheld dynamometers (HHDs) are more portable, affordable, and may provide valid and reliable results which would increase the clinical utility of long-lever tests. HHDs vary in shape, design, and their capacity to report parameters such as rate of force production and require further investigation. The aim of this study was to examine the intrarater reliability of the Kinvent HHD and assess its validity against Kinvent force plates in the AST. Peak force (in kilograms), torque (in Newton meters), and normalized torque (in Newton meters per kilogram) were reported. Design: Validity and reliability study.Methods: Twenty-seven participants with no history of upper limb injury performed the test in a randomized order using the Kinvent HHD and force plates. Each condition was assessed 3 times, and peak force was recorded. Arm length was measured to calculate peak torque. Normalized peak torque was calculated by dividing torque by bodyweight (in kilograms).Results: The Kinvent HHD is reliable when measuring force (intraclass correlation coefficient [ICC] >_ .80), torque (ICC >_ .84), and normalized torque (ICC >_ .64) during the AST. The Kinvent HHD is also valid when compared with the Kinvent force plates for force (ICC >_ .79; r >_ .82), torque (ICC >_ .82; r >_ .76), and normalized torque (ICC >_ .71; r >_ .61). There were no statistically significant differences across the 3 trials on analyses of variance (P > .05).Conclusions: The Kinvent HHD is a reliable tool when used to measure force, torque, and normalized torque in the AST. Furthermore, given the lack of significant difference between trials, clinicians can use one test to accurately report relative peak force/torque/ normalized torque rather than average 3 separate trials. Finally, the Kinvent HHD is valid when compared with Kinvent force plates.
引用
收藏
页码:764 / 772
页数:9
相关论文
共 50 条
  • [41] The Penn Shoulder Score: Reliability and validity
    Leggin, BG
    Michener, LA
    Shaffer, MA
    Brenneman, SK
    Iannotti, JP
    Williams, GR
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2006, 36 (03): : 138 - 151
  • [42] VALIDITY AND RELIABILITY OF A HANDHELD BLOOD GLUCOSE MONITOR DURING EXERCISE AND AN ORAL GLUCOSE TOLERANCE TEST
    Granderson, Davoncie M.
    Camic, Clayton L.
    Chomentowski, Peter J.
    Howell, Steven M.
    Sebastiao, Emerson
    KINESIOLOGY, 2019, 51 (02) : 182 - 188
  • [43] Validity and reliability of an isomatric dynamometer as an evaluative teal in a rehabilitative clinic
    Dainty, D
    Mior, S
    Bereznick, D
    JOURNAL OF SPORTS CHIROPRACTIC & REHABILITATION, 1998, 12 (03): : 109 - 117
  • [44] Reliability and validity of an electronic dynamometer for measuring grip strength COMMENT
    Fitinghoff, Helene
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 265 - 265
  • [45] Technical report: Reliability and validity of the iSAM 9000 isokinetic dynamometer
    Orri, Julia C.
    Darden, Gibson F.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2008, 22 (01) : 310 - 317
  • [46] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 229 - 234
  • [47] Reliability and Validity of the Multiaxis Profile Dynamometer with Younger and Older Participants
    Irwin, Curt B.
    Sesto, Mary E.
    JOURNAL OF HAND THERAPY, 2010, 23 (03) : 281 - 288
  • [48] The validity and reliability of the handheld SW-100 autokeratometer
    Iyamu, Eghosasere
    Amiebenomo, O. Mary-Anne
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2015, 74 (01):
  • [49] Reliability, validity, and responsiveness of the simple shoulder test: Psychometric properties by age and injury type
    Godfrey, Jenna
    Hamman, Richard
    Lowenstein, Steven
    Briggs, Karen
    Kocher, Mininder
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (03) : 260 - 267
  • [50] Criterion validity of the kinematics of an isokinetic dynamometer to assess shoulder function in tennis players
    Tunstall, H
    Mullineaux, DR
    Vernon, T
    JOURNAL OF SPORTS SCIENCES, 2003, 21 (04) : 251 - 252