Validity and Reliability of the Kinvent Handheld Dynamometer in the Athletic Shoulder Test

被引:8
|
作者
Olds, Margie [1 ,2 ]
McLaine, Sally [3 ]
Magni, Nico [4 ]
机构
[1] Flawless Mot Ltd, Auckland, New Zealand
[2] Univ Otago, Dept Physiotherapy, Dunedin, New Zealand
[3] Univ Tasmania, Sch Hlth Sci, Physiotas Launceston, Hobart, Tas, Australia
[4] Auckland Univ Technol, Sch Clin Sci, Dept Physiotherapy, Auckland, New Zealand
关键词
strength assessment; torque; force; return to sport; RUGBY UNION; INJURIES;
D O I
10.1123/jsr.2022-0444
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Long-lever shoulder strength tests may aid clinical decision-making regarding return to sport after a shoulder injury. The Athletic Shoulder Test (AST) was developed to measure force production in 3 positions of shoulder abduction (90 degrees, 135 degrees, and 180 degrees) using force plates. However, handheld dynamometers (HHDs) are more portable, affordable, and may provide valid and reliable results which would increase the clinical utility of long-lever tests. HHDs vary in shape, design, and their capacity to report parameters such as rate of force production and require further investigation. The aim of this study was to examine the intrarater reliability of the Kinvent HHD and assess its validity against Kinvent force plates in the AST. Peak force (in kilograms), torque (in Newton meters), and normalized torque (in Newton meters per kilogram) were reported. Design: Validity and reliability study.Methods: Twenty-seven participants with no history of upper limb injury performed the test in a randomized order using the Kinvent HHD and force plates. Each condition was assessed 3 times, and peak force was recorded. Arm length was measured to calculate peak torque. Normalized peak torque was calculated by dividing torque by bodyweight (in kilograms).Results: The Kinvent HHD is reliable when measuring force (intraclass correlation coefficient [ICC] >_ .80), torque (ICC >_ .84), and normalized torque (ICC >_ .64) during the AST. The Kinvent HHD is also valid when compared with the Kinvent force plates for force (ICC >_ .79; r >_ .82), torque (ICC >_ .82; r >_ .76), and normalized torque (ICC >_ .71; r >_ .61). There were no statistically significant differences across the 3 trials on analyses of variance (P > .05).Conclusions: The Kinvent HHD is a reliable tool when used to measure force, torque, and normalized torque in the AST. Furthermore, given the lack of significant difference between trials, clinicians can use one test to accurately report relative peak force/torque/ normalized torque rather than average 3 separate trials. Finally, the Kinvent HHD is valid when compared with Kinvent force plates.
引用
收藏
页码:764 / 772
页数:9
相关论文
共 50 条
  • [31] Validity and Reliability of Kinvent Plates for Assessing Single Leg Static and Dynamic Balance in the Field
    Serrano, Hugo Meras
    Mottet, Denis
    Caillaud, Kevin
    SENSORS, 2023, 23 (04)
  • [32] THE RELATIVE AND ABSOLUTE RELIABILITY OF LEG MUSCLE STRENGTH TESTING BY A HANDHELD DYNAMOMETER
    Lu, Yen-Mou
    Lin, Jau-Hong
    Hsiao, Shih-Fen
    Liu, Mei-Fang
    Chen, Shu-Mei
    Lue, Yi-Jing
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (04) : 1065 - 1071
  • [33] Reliability intra and inter-rater of a handheld dynamometer in COPD patients
    Sentanin, Anna
    Facio, Carina de Araujo
    Di Lorenzo, Valeria Amorim Pires
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [34] Reliability and Validity of a Novel Isokinetic Knee Dynamometer System
    Riemann, Bryan L.
    Watson, Matthew D.
    Davies, George J.
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2021, 23 (04) : 107 - 116
  • [35] Reliability and validity of an electronic dynamometer for measuring grip strength
    Allen, Deborah
    Barnett, Fiona
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 258 - 264
  • [36] Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity
    Martinez-Garcia, Dario
    Rodriguez-Perea, Angela
    Barboza, Paola
    Ulloa-Diaz, David
    Jerez-Mayorga, Daniel
    Chirosa, Ignacio
    Chirosa Rios, Luis Javier
    PEERJ, 2020, 8
  • [37] The Athletic Shoulder (ASH) test: reliability of a novel upper body isometric strength test in elite rugby players
    Ashworth, Ben
    Hogben, Patrick
    Singh, Navraj
    Tulloch, Laura
    Cohen, Daniel D.
    BMJ OPEN SPORT & EXERCISE MEDICINE, 2018, 4 (01):
  • [38] Cross-Cultural Validity and Reliability of the Thai Version of the Simple Shoulder Test
    Thamrongskulsiri, Napatpong
    Wiwatboworn, Arnan
    Itthipanichpong, Thun
    Tanpowpong, Thanathep
    Kuptniratsaikul, Somsak
    Limskul, Danaithep
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2025, 13 (01)
  • [39] Concurrent validity and test-retest reliability of Squegg™ - smart dynamometer and handgrip trainer in healthy individuals
    Amin, Zarmina
    Gutierrez, Galilea
    True, Larissa
    HAND THERAPY, 2024, 29 (02) : 68 - 74
  • [40] INFLUENCE OF TESTING POSITION ON THE RELIABILITY OF HIP EXTENSOR STRENGTH MEASURED BY A HANDHELD DYNAMOMETER
    Lue, Yi-Jing
    Hsieh, Ching-Lin
    Liu, Mei-Fang
    Hsiao, Shih-Fen
    Chen, Shu-Mei
    Lin, Jau-Hong
    Lu, Yen-Mou
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2009, 25 (03): : 126 - 132