Validity and Reliability of the Kinvent Handheld Dynamometer in the Athletic Shoulder Test

被引:8
|
作者
Olds, Margie [1 ,2 ]
McLaine, Sally [3 ]
Magni, Nico [4 ]
机构
[1] Flawless Mot Ltd, Auckland, New Zealand
[2] Univ Otago, Dept Physiotherapy, Dunedin, New Zealand
[3] Univ Tasmania, Sch Hlth Sci, Physiotas Launceston, Hobart, Tas, Australia
[4] Auckland Univ Technol, Sch Clin Sci, Dept Physiotherapy, Auckland, New Zealand
关键词
strength assessment; torque; force; return to sport; RUGBY UNION; INJURIES;
D O I
10.1123/jsr.2022-0444
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Long-lever shoulder strength tests may aid clinical decision-making regarding return to sport after a shoulder injury. The Athletic Shoulder Test (AST) was developed to measure force production in 3 positions of shoulder abduction (90 degrees, 135 degrees, and 180 degrees) using force plates. However, handheld dynamometers (HHDs) are more portable, affordable, and may provide valid and reliable results which would increase the clinical utility of long-lever tests. HHDs vary in shape, design, and their capacity to report parameters such as rate of force production and require further investigation. The aim of this study was to examine the intrarater reliability of the Kinvent HHD and assess its validity against Kinvent force plates in the AST. Peak force (in kilograms), torque (in Newton meters), and normalized torque (in Newton meters per kilogram) were reported. Design: Validity and reliability study.Methods: Twenty-seven participants with no history of upper limb injury performed the test in a randomized order using the Kinvent HHD and force plates. Each condition was assessed 3 times, and peak force was recorded. Arm length was measured to calculate peak torque. Normalized peak torque was calculated by dividing torque by bodyweight (in kilograms).Results: The Kinvent HHD is reliable when measuring force (intraclass correlation coefficient [ICC] >_ .80), torque (ICC >_ .84), and normalized torque (ICC >_ .64) during the AST. The Kinvent HHD is also valid when compared with the Kinvent force plates for force (ICC >_ .79; r >_ .82), torque (ICC >_ .82; r >_ .76), and normalized torque (ICC >_ .71; r >_ .61). There were no statistically significant differences across the 3 trials on analyses of variance (P > .05).Conclusions: The Kinvent HHD is a reliable tool when used to measure force, torque, and normalized torque in the AST. Furthermore, given the lack of significant difference between trials, clinicians can use one test to accurately report relative peak force/torque/ normalized torque rather than average 3 separate trials. Finally, the Kinvent HHD is valid when compared with Kinvent force plates.
引用
收藏
页码:764 / 772
页数:9
相关论文
共 50 条
  • [21] Reliability and Validity of the End Range Hamstring Strength Test with Handheld Dynamometry
    Kristiansen, Jakob
    Eddy, Christina
    Magnusson, Stig Peter
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2024, 19 (03): : 268 - 274
  • [22] Turkish version of the Simple Shoulder Test: a reliability and validity study
    Ayhan, Cigdem
    Unal, Edibe
    Yakut, Yavuz
    TURKISH JOURNAL OF PHYSIOTHERAPY REHABILITATION-FIZYOTERAPI REHABILITASYON, 2010, 21 (02): : 68 - 74
  • [23] Validity and reliability of an inertial dynamometer using accelerometry
    Jidovtseff, B.
    Crielaard, J. -M.
    Cauchy, S.
    Croisier, J. -L.
    SCIENCE & SPORTS, 2008, 23 (02) : 94 - 97
  • [24] Test-retest reliability of expiratory abdominal compression with a handheld dynamometer in patients with prolonged mechanical ventilation
    Morino, Akira
    Shida, Masahiro
    Tanaka, Masashi
    Sato, Kimihiro
    Seko, Toshiaki
    Ito, Shunsuke
    Ogawa, Shunichi
    Takahashi, Naoaki
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (07) : 2163 - 2165
  • [25] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57
  • [26] Reliability and validity of the iSAM 9000 isokinetic dynamometer
    Orri, JC
    Darden, GE
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2006, 77 (01) : A39 - A40
  • [27] Shoulder Performance Activity Test (SPAT) for People With Shoulder Pain: Feasibility, Reliability and Validity
    Sousa, Catarina O.
    Nascimento, Jose Diego S.
    Pozzi, Federico
    Kardouni, Joseph R.
    Michener, Lori A.
    PHYSICAL THERAPY, 2023, 103 (03):
  • [28] Reliability and validity of trunk flexor and trunk extensor strength measurements using handheld dynamometry in a healthy athletic population
    De Blaiser, Cedric
    De Ridder, Roel
    Willems, Tine
    Danneels, Lieven
    Roosen, Philip
    PHYSICAL THERAPY IN SPORT, 2018, 34 : 180 - 186
  • [29] Reliability and Validity of the ActivForce Digital Dynamometer in Assessing Shoulder Muscle Force across Different User Experience Levels
    Karagiannopoulos, Christos
    Griech, Sean
    Leggin, Brian
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2022, 17 (04): : 669 - 676
  • [30] Handheld Dynamometer for Hamstring Strength Test Using Two Different Hand Placements/Methods: An Interrater Reliability Study
    Koc Jr, Thomas A.
    Tucker, Jenna
    Gentile, Jennifer
    Enriquez, Carla
    Lee, John
    Jeanty, Seide
    Krasowski, Natalia
    REHABILITATION RESEARCH AND PRACTICE, 2024, 2024 (01)