strength assessment;
torque;
force;
return to sport;
RUGBY UNION;
INJURIES;
D O I:
10.1123/jsr.2022-0444
中图分类号:
R49 [康复医学];
学科分类号:
100215 ;
摘要:
Context: Long-lever shoulder strength tests may aid clinical decision-making regarding return to sport after a shoulder injury. The Athletic Shoulder Test (AST) was developed to measure force production in 3 positions of shoulder abduction (90 degrees, 135 degrees, and 180 degrees) using force plates. However, handheld dynamometers (HHDs) are more portable, affordable, and may provide valid and reliable results which would increase the clinical utility of long-lever tests. HHDs vary in shape, design, and their capacity to report parameters such as rate of force production and require further investigation. The aim of this study was to examine the intrarater reliability of the Kinvent HHD and assess its validity against Kinvent force plates in the AST. Peak force (in kilograms), torque (in Newton meters), and normalized torque (in Newton meters per kilogram) were reported. Design: Validity and reliability study.Methods: Twenty-seven participants with no history of upper limb injury performed the test in a randomized order using the Kinvent HHD and force plates. Each condition was assessed 3 times, and peak force was recorded. Arm length was measured to calculate peak torque. Normalized peak torque was calculated by dividing torque by bodyweight (in kilograms).Results: The Kinvent HHD is reliable when measuring force (intraclass correlation coefficient [ICC] >_ .80), torque (ICC >_ .84), and normalized torque (ICC >_ .64) during the AST. The Kinvent HHD is also valid when compared with the Kinvent force plates for force (ICC >_ .79; r >_ .82), torque (ICC >_ .82; r >_ .76), and normalized torque (ICC >_ .71; r >_ .61). There were no statistically significant differences across the 3 trials on analyses of variance (P > .05).Conclusions: The Kinvent HHD is a reliable tool when used to measure force, torque, and normalized torque in the AST. Furthermore, given the lack of significant difference between trials, clinicians can use one test to accurately report relative peak force/torque/ normalized torque rather than average 3 separate trials. Finally, the Kinvent HHD is valid when compared with Kinvent force plates.
机构:
Sport Sci Sch Rio Maior, Rio Maior, Portugal
CIDESD, Res Ctr Sports Hlth & Human Dev, STRONG Res Community, Vila Real, Portugal
CIEQV Life Qual Res Ctr, Santarem, PortugalSport Sci Sch Rio Maior, Rio Maior, Portugal
Conceicao, Ana
Parraca, Jose
论文数: 0引用数: 0
h-index: 0
机构:
CIDESD, Res Ctr Sports Hlth & Human Dev, STRONG Res Community, Vila Real, Portugal
Univ Evora, CHRC, Evora, Portugal
Univ Evora, Sch Sci & Technol, Dept Sport & Hlth, Evora, PortugalSport Sci Sch Rio Maior, Rio Maior, Portugal
Parraca, Jose
论文数: 引用数:
h-index:
机构:
Marinho, Daniel
Costa, Mario
论文数: 0引用数: 0
h-index: 0
机构:
CIDESD, Res Ctr Sports Hlth & Human Dev, STRONG Res Community, Vila Real, Portugal
Polytech Inst Guarda, Dept Sport Sci, Guarda, PortugalSport Sci Sch Rio Maior, Rio Maior, Portugal
Costa, Mario
Louro, Hugo
论文数: 0引用数: 0
h-index: 0
机构:
Sport Sci Sch Rio Maior, Rio Maior, Portugal
CIDESD, Res Ctr Sports Hlth & Human Dev, STRONG Res Community, Vila Real, PortugalSport Sci Sch Rio Maior, Rio Maior, Portugal
Louro, Hugo
Silva, Antonio
论文数: 0引用数: 0
h-index: 0
机构:
CIDESD, Res Ctr Sports Hlth & Human Dev, STRONG Res Community, Vila Real, Portugal
Univ Tras Os Montes & Alto Douro, Vila Real, PortugalSport Sci Sch Rio Maior, Rio Maior, Portugal
Silva, Antonio
Batalha, Nuno
论文数: 0引用数: 0
h-index: 0
机构:
CIDESD, Res Ctr Sports Hlth & Human Dev, STRONG Res Community, Vila Real, Portugal
Univ Evora, CHRC, Evora, Portugal
Univ Evora, Sch Sci & Technol, Dept Sport & Hlth, Evora, PortugalSport Sci Sch Rio Maior, Rio Maior, Portugal