Simplified shear equation of deep concrete beam considering orientation effect of opening and mechanical properties of fibre-concrete interface

被引:5
作者
Augustino, Daudi Salezi [1 ]
Kanali, Christopher [2 ]
Onchiri, Richard Ocharo [3 ]
Kabubo, Charles [4 ]
机构
[1] Univ Dar es Salaam, Dept Struct & Construct Engn, Dar es Salaam, Tanzania
[2] Jomo Kenyatta Univ Agr & Technol, Dept Agr & Biosyst Engn, Nairobi, Kenya
[3] Tech Univ Mombasa, Dept Bldg & Civil Engn, Mombasa, Kenya
[4] Jomo Kenyatta Univ Agr & Technol, Dept Civil Construct & Environm Engn, Nairobi, Kenya
关键词
Shear capacity; Deep concrete beam; Simplified shear equation; Fibre -concrete interface; Internal strengthening; DRYING SHRINKAGE; STEEL; STRENGTH; PERFORMANCE; BEHAVIOR;
D O I
10.1016/j.heliyon.2023.e14441
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In the present era of technology, the design of structural deep concrete beams is highly modernized through the use of computer-aided tools. However, theories for such design are the paramount aspects to be understood particularly when the beam has openings. To improve the mechanical properties of the deep beam with openings, recycled tyre steel fibres are required. To estimate the bond strength of the fibre-concrete interface, the concrete shrinkage strains for fibre lengths 30, 50 and 60 mm with a content of 0.5% were considered. To mitigate the conservativeness of some available shear models and improve the design of deep beams, the simplified shear equation model was developed. The model was established using a simplified compressive stress block, forces in steel reinforcement and shear stress at the fibre-concrete interface. The combined effect of opening height and length was also considered in the model. The results show that incorporating fibres in concrete increase the shear performance of deep concrete beams with openings due to high strains in the shear zone indicating high loads being transferred. For instance, beam BS2 had a strain of 0.0153 in the lower load path compared to 5.6 x 10-5 for beam BC2 There was a good correlation between measured and proposed shear capacities with t-test values of 0.46, 0.996 and 0.003 for beams without fibres, and with fibres and mesh respectively. Results also showed the model shear equation performed better compared to other equations with mean absolute error (MAE) and coefficient of variation (COV) of 9.3 and 18.9%, respectively for the control beams with openings. The model also showed a mean absolute error (MAE) and coefficient of variation (COV) of 11.6 and 7.4%, respectively for the beams with fibres. The COV and MAE for the proposed model were small than those in the database, therefore, the proposed model can provide the precise design of deep concrete beams with openings and fibres.
引用
收藏
页数:18
相关论文
共 64 条
  • [51] SCHLAICH J, 1987, J PRESTR CONCRETE I, V32, P74
  • [52] The effect of elevated temperatures on the properties of cold-drawn steel fibres
    Serafini, Ramoel
    Mendes, Livia Mourao
    Salvador, Renan Picolo
    de Figueiredo, Antonio Domingues
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2021, 73 (18) : 936 - 944
  • [53] Shahnewaz M, 2014, ACI STRUCT J, V111, P851
  • [54] Shanmugam N.E., 1988, International Journal of Cement Composites and Lightweight Concrete, V10, P53
  • [55] SHARMA AK, 1986, J AM CONCRETE I, V83, P624
  • [56] Predicting the shear strength of steel fiber reinforced concrete beams
    Slater, Emma
    Moni, Moniruzzaman
    Alam, M. Shahria
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2012, 26 (01) : 423 - 436
  • [57] Analysis of Failure Mechanics in Hybrid Fibre-Reinforced High-Performance Concrete Deep Beams with and without Openings
    Smarzewski, Piotr
    [J]. MATERIALS, 2019, 12 (01):
  • [58] Influence of Different Surfactants on Carbon Fiber Dispersion and the Mechanical Performance of Smart Piezoresistive Cementitious Composites
    Thomoglou, Athanasia K.
    Falara, Maria G.
    Gkountakou, Fani, I
    Elenas, Anaxagoras
    Chalioris, Constantin E.
    [J]. FIBERS, 2022, 10 (06)
  • [59] Van der Aa P.J., 2014, BIAXIAL STRESSES STE
  • [60] Cracking Diagnosis in Fiber-Reinforced Concrete with Synthetic Fibers Using Piezoelectric Transducers
    Voutetaki, Maristella E.
    Naoum, Maria C.
    Papadopoulos, Nikos A.
    Chalioris, Constantin E.
    [J]. FIBERS, 2022, 10 (01)