Real-time ultrasensitive detection of ammonia gas using a compact CRDS spectrometer

被引:3
作者
Lee, Jaebeom [1 ]
Oh, Myoung-Kyu [2 ]
机构
[1] Woosung E&D Co, Osan Si 18102, Gyeonggi Do, South Korea
[2] Gwangju Inst Sci & Technol GIST, Adv Photon Res Inst APRI, Gwangju 61005, South Korea
关键词
CAVITY RING-DOWN; SPECTROSCOPY; LASER; BREATH; SCHEMES;
D O I
10.1364/AO.477575
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Trace-level ammonia gas in air was analyzed using a fiber-based compact cavity ring-down spectrometer (CRDS). For the compact spectrometer, a 20 cm linear cavity with two high reflectivity (>99.999%) mirrors was employed. The laser frequency was locked to the cavity resonance by using frequency shifted (160 MHz) optical feedback. For NH3 detection, a strong absorption band at 1513.98 nm with an absorption cross section of 3.3 middot 10-21 cm/molecule was used. As a result, a detection sensitivity of similar to 0.1 ppb (3-Sigma) was achieved for NH3 within 10 s.(c) 2023 Optica Publishing Group
引用
收藏
页码:1357 / 1363
页数:7
相关论文
共 28 条
[1]  
[Anonymous], The HITRAN Database
[2]   Cavity ring-down spectroscopy: Experimental schemes and applications [J].
Berden, G ;
Peeters, R ;
Meijer, G .
INTERNATIONAL REVIEWS IN PHYSICAL CHEMISTRY, 2000, 19 (04) :565-607
[3]   Optical feedback frequency stabilized cavity ring-down spectroscopy [J].
Burkart, Johannes ;
Romanini, Daniele ;
Kassi, Samir .
OPTICS LETTERS, 2014, 39 (16) :4695-4698
[4]  
Crosson E. R., ANAL CHEM, V74
[5]   Online monitoring of ethane traces in exhaled breath with a difference frequency generation spectrometer [J].
Halmer, D. ;
Thelen, S. ;
Hering, P. ;
Muertz, M. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3) :437-443
[6]   Detection of trace gases by rapidly-swept continuous-wave cavity ringdown spectroscopy: pushing the limits of sensitivity [J].
He, Y. ;
Orr, B. J. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3) :355-364
[7]   A Fiber-Integrated CRDS Sensor for In-Situ Measurement of Dissolved Carbon Dioxide in Seawater [J].
Hu, Mai ;
Chen, Bing ;
Yao, Lu ;
Yang, Chenguang ;
Chen, Xiang ;
Kan, Ruifeng .
SENSORS, 2021, 21 (19)
[8]  
Kachanov A., 2014, U.S. patent, Patent No. [8,885,167B2, 8885167]
[9]   Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath [J].
Luo, Zhifu ;
Tan, Zhongqi ;
Long, Xingwu .
SENSORS, 2019, 19 (17)
[10]   Pulsed quantum cascade laser-based cavity ring-down spectroscopy for ammonia detection in breath [J].
Manne, Jagadeeshwari ;
Sukhorukov, Oleksandr ;
Jager, Wolfgang ;
Tulip, John .
APPLIED OPTICS, 2006, 45 (36) :9230-9237