摘要
The phenomenon of transformer dc bias (TDB) will saturate the transformer core, resulting in the local overheating, accelerating the ageing of insulating material, and even affecting the transformer safe operation. Therefore, it is of great significance to carry out the TDB detection and suppression. In this article, first, according to the distortion characteristics of the transformer excitation current under TDB. This article presents a method for measuring the bias voltage content of the transformer in the ac/dc environment to detect TDB. Second, the value of TDB is calculated by measuring the voltage difference before and after the dc bias, so as to obtain the degree of TDB. The feasibility of this scheme is verified by multigroup simulations of single-phase transformer (SPT) and three-phase transformer (TPT). Finally, the SPT and TPT simulated experiments of TDB are designed, and one kind of TDB suppression is carried out based on a hybrid transformer model. The experimental results are in good agreement with the simulation results, which can provide certain reference for TDB control in the dc transmission and ac/dc distribution networks.
引用
收藏
页码:7853 / 7863
页数:11
相关论文
共 50 条
  • [1] Influence of DC Bias to Transformer and Its Suppression Measures
    Du Huazhu
    Wen Xishan
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [2] Monitoring and Suppression Measures of Transformer DC Bias Current
    Jiang, W.
    He, L.
    Zhang, Z. X.
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 364 - 367
  • [3] Saturation characteristics of a transformer under DC bias and their influence on the distribution of DC current in an AC power grid
    Weng Hanli
    Li Haowei
    Li Zhenxing
    Huang Jingguang
    Lin Xiangning
    Liu Lei
    Wang Sheng
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 14 (02) : 231 - 237
  • [4] Measures of transformer DC bias suppression based on dual protection topology
    Li, Changyun
    Li, Qingmin
    Li, Zhen
    Yao, Jinxia
    Liu, Min
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2012, 32 (01): : 71 - 75
  • [5] Research on power transformer vibration and noise under DC bias condition
    Ai, Mengmeng
    Liu, Wenhui
    Shan, Yi
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2022, 68 (03) : 371 - 385
  • [6] DC Bias Suppression Scheme Based on Hybrid Transformer
    Xia Fei
    Chen Zhiwei
    Linzi, Danfeng
    He Linjia
    Jing Chen
    Wang Gang
    2022 25TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2022), 2022,
  • [7] Study on the Network Suppressing Measures of the DC Bias Current in AC Power System
    Zhao Dandan
    Fu Chenzhao
    Su Lei
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 594 - 598
  • [8] Research on DC magnetic Bias of Power Transformer
    Zhou, Xuesong
    Zhou, Zhihao
    Ma, Youjie
    2012 INTERNATIONAL WORKSHOP ON INFORMATION AND ELECTRONICS ENGINEERING, 2012, 29 : 452 - 455
  • [9] Experimental Study on Transformer under DC Bias
    Hu, Yang
    Li, Huiqi
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 2186 - 2189
  • [10] Research on Core Vibration of Y/Δ Transformer Under AC/DC Hybrid Environment
    Pan C.
    Su H.
    Cai G.
    Li X.
    Pan, Chao (31563018@qq.com), 1600, Science Press (46): : 2388 - 2397