Thickness Measurement of Self-Lubricating Fabric Liner of Inner Ring of Sliding Bearings Using Spectral-Domain Optical Coherence Tomography

被引:5
作者
Deng, Yaosen [1 ]
Zhong, Shuncong [1 ]
Lin, Jiewen [1 ,2 ]
Zhang, Qiukun [1 ]
Nsengiyumva, Walter [1 ]
Cheng, Shuying [2 ]
Huang, Yi [1 ,3 ]
Chen, Zhixiong [3 ]
机构
[1] Fuzhou Univ, Sch Mech Engn & Automat, Fujian Prov Key Lab Terahertz Funct Devices & Inte, Fuzhou 350116, Peoples R China
[2] Fuzhou Univ, Sch Phys & Informat Engn, Fuzhou 350116, Peoples R China
[3] Fujian Longxi Bearing Grp Corp Ltd, Zhangzhou 363000, Peoples R China
基金
中国国家自然科学基金;
关键词
optical coherence tomography (OCT); group refractivity; geometric thickness; Hanning-windowed energy centrobaric method (HnWECM); self-lubricating fabric liner; REFRACTIVE-INDEX; COMPOSITE; GRAPHENE;
D O I
10.3390/coatings13040708
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study presents a novel and highly accurate method of measuring the geometric thickness of the self-lubricating fabric liner of bearings by combining the optical coherence tomography (OCT) technology and the Hanning-windowed energy centrobaric method (HnWECM). The geometric thickness of wear-resistant coating material is one of the important indicators for evaluating its wear, and the measurement of its geometric thickness is of great significance for preventing coating failure. To address the issue of significant measurement errors caused by using the refractive index of the sample instead of the group refractive index to calculate the material's geometrical thickness in previous OCT research and applications, our proposed method can accurately measure the geometrical thickness of materials without the influence of the refractive index of the material. Moreover, this method exhibits the advantages of non-contact and high precision, since it utilizes an SD-OCT system, making it a novel method for extracting the physical parameters of composite materials. The geometric thickness of the peeled-off liner obtained from our method is compared with the thickness measured by the spiral micrometer to evaluate its accuracy. The experimental results indicate that the thickness measured by the spiral micrometer was 172 mu m, while the maximum difference in the data obtained by our method was 171.261 mu m. This suggests that the difference between the two methods is less than 0.430%, which verifies the accuracy and validity of our method. Additionally, the obtained geometric thickness and the optical thickness of the peeled-off liner are used to evaluate the group refractive index of this material. The inside geometrical structure of the self-lubricating fabric liner on the end face and inner ring of the sliding bearing is imaged with this group refractive index. The measurement of the inner ring liner of the sliding bearing proves the flexibility of the fiber-optic OCT and provides a non-contact, nondestructive testing method for measuring the geometric thickness and internal geometric structure of composite materials.
引用
收藏
页数:13
相关论文
共 31 条
  • [1] AN UPDATED EDLEN EQUATION FOR THE REFRACTIVE-INDEX OF AIR
    BIRCH, KP
    DOWNS, MJ
    [J]. METROLOGIA, 1993, 30 (03) : 155 - 162
  • [2] Wear resistance of HVOF- and HVAF-sprayed (Ti,Mo)(C,N)-Ni coatings from an agglomerated and sintered powder
    Bolelli, Giovanni
    Lyphout, Christophe
    Berger, Lutz-Michael
    Testa, Veronica
    Myalska-Glowacka, Hanna
    Puddu, Pietro
    Sassatelli, Paolo
    Lusvarghi, Luca
    [J]. WEAR, 2023, 512-513
  • [3] Biocompatible polymer materials: Role of protein-surface interactions
    Chen, Hong
    Yuan, Lin
    Song, Wei
    Wu, Zhongkui
    Li, Dan
    [J]. PROGRESS IN POLYMER SCIENCE, 2008, 33 (11) : 1059 - 1087
  • [4] SIMULTANEOUS ACOUSTIC-EMISSION AND ULTRASONIC TOMOGRAPHIC IMAGING IN ANISOTROPIC POLYMER COMPOSITE-MATERIAL
    CHOW, TM
    HUTCHINS, DA
    MOTTRAM, JT
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 94 (02) : 944 - 953
  • [5] Individual fibre separation in 3D fibrous materials imaged by X-ray tomography
    Depriester, Dorian
    du Roscoat, Sabine Rolland
    Orgeas, Laurent
    Geindreau, Christian
    Levrard, Benjamin
    Bremond, Florian
    [J]. JOURNAL OF MICROSCOPY, 2022, 286 (03) : 220 - 239
  • [6] Simultaneous measurement of temperature-dependent refractive index and depth-resolved thermal deformation fields inside polymers
    Dong, Bo
    Xie, Shengli
    He, Zhaoshui
    Zhou, Yanzhou
    [J]. POLYMER TESTING, 2018, 65 : 297 - 300
  • [7] MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY
    FERCHER, AF
    HITZENBERGER, CK
    KAMP, G
    ELZAIAT, SY
    [J]. OPTICS COMMUNICATIONS, 1995, 117 (1-2) : 43 - 48
  • [8] Optical coherence tomography image analysis of polymer surface layers in sound-absorbing fibrous composite materials
    Gliscinska, Eulalia
    Sankowski, Dominik
    Krucinska, Izabella
    Goclawski, Jaroslaw
    Michalak, Marina
    Rowinska, Zdzislawa
    Sekulska-Nalewajko, Joanna
    [J]. POLYMER TESTING, 2017, 63 : 194 - 203
  • [9] Extraction of the Polyurethane Layer in Textile Composites for Textronics Applications Using Optical Coherence Tomography
    Goclawski, Jaroslaw
    Korzeniewska, Ewa
    Sekulska-Nalewajko, Joanna
    Sankowski, Dominik
    Pawlak, Ryszard
    [J]. POLYMERS, 2018, 10 (05)
  • [10] Polymer surface modification for the attachment of bioactive compounds
    Goddard, J. M.
    Hotchkiss, J. H.
    [J]. PROGRESS IN POLYMER SCIENCE, 2007, 32 (07) : 698 - 725