Structural Design of Dual-Type Thin-Film Thermopiles and Their Heat Flow Sensitivity Performance

被引:7
作者
Chen, Hao [1 ,2 ]
Liu, Tao [3 ]
Feng, Nanming [1 ,2 ]
Shi, Yeming [1 ,2 ]
Zhou, Zigang [3 ]
Dai, Bo [1 ]
机构
[1] Southwest Univ Sci & Technol, State Key Lab Environm Friendly Energy Mat, Mianyang 621010, Sichuan, Peoples R China
[2] Southwest Univ Sci & Technol, Sch Mat & Chem, Mianyang 621010, Sichuan, Peoples R China
[3] Southwest Univ Sci & Technol, Sch Math & Sci, Mianyang 621010, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
thin-film type; heat flowsensor; thermal resistance layer; thermopile; finite element simulation; FLUX; TEMPERATURE;
D O I
10.3390/mi14071458
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aiming at the shortcomings of the traditional engineering experience in designing thin-film heat flow meters, such as low precision and long iteration time, the finite element analysis model of thin-film heat flow meters is established based on finite element simulation methods, and a double-type thin-film heat flow sensor based on a copper/concentrate thermopile is made. The influence of the position of the thermal resistance layer, heat flux density and thickness of the thermal resistance layer on the temperature gradient of the hot and cold ends of the heat flow sensor were comprehensively analyzed by using a simulation method. When the applied heat flux density is 50 kW/m(2) and the thermal resistance layer is located above and below the thermopile, respectively, the temperature difference between the hot junction and the cold junction is basically the same, but comparing the two, the thermal resistance layer located above is more suitable for rapid measurements of heat flux at high temperatures. In addition, the temperature difference between the hot and cold contacts of the thin-film heat flux sensor increases linearly with the thickness of the thermal resistance layer. Finally, we experimentally tested the response-recovery characteristics of the sensors, with a noise of 2.1 mu V and a maximum voltage output of 15 mu V in a room temperature environment, respectively, with a response time of about 2 s and a recovery time of about 3 s. Therefore, the device we designed has the characteristic of double-sided use, which can greatly expand the scope of use and service life of the device and promote the development of a new type of heat flow meter, which will provide a new method for the measurement of heat flow density in the complex environment on the surface of the aero-engine.
引用
收藏
页数:12
相关论文
共 36 条
[1]   Modeling heat conduction in an infinite media using the thermoelastic MGT equations and the magneto-Seebeck effect under the influence of a constant stationary source [J].
Abouelregal, Ahmed E. ;
Tiwari, Rakhi ;
Nofal, Taher A. .
ARCHIVE OF APPLIED MECHANICS, 2023, 93 (05) :2113-2128
[2]  
ASTM, 2007, ASTM E511-07
[3]   Thermal Flow Sensors for Harsh Environments [J].
Balakrishnan, Vivekananthan ;
Hoang-Phuong Phan ;
Toan Dinh ;
Dzung Viet Dao ;
Nam-Trung Nguyen .
SENSORS, 2017, 17 (09)
[4]   Study on the Thermal Distribution Characteristics of a Molten Quartz Ceramic Surface under Quartz Lamp Radiation [J].
Chen, Hao ;
Li, Wei ;
Zhu, Shimin ;
Hou, Aiqiang ;
Liu, Tao ;
Xu, Jiangshan ;
Zhang, Xiaowei ;
Yi, Zao ;
Yi, Yougen ;
Dai, Bo .
MICROMACHINES, 2023, 14 (06)
[5]   Design and Fabrication of a Thermopile-Based Thin Film Heat Flux Sensor, Using a Lead-Substrate Integration Method [J].
Cui, Yunxian ;
Liu, Hui ;
Wang, Haoyu ;
Guo, Shuning ;
E, Mingfeng ;
Ding, Wanyu ;
Yin, Junwei .
COATINGS, 2022, 12 (11)
[6]   Local instantaneous heat flux measurements in an internal combustion engine using a MEMS sensor [J].
Dejima, Kazuhito ;
Nakabeppu, Osamu .
APPLIED THERMAL ENGINEERING, 2022, 201
[7]   High-speed and low-power thermally tunable devices with suspended silicon waveguide [J].
Duan, Fei ;
Chen, Kai ;
Yu, Yonglin .
OPTICAL AND QUANTUM ELECTRONICS, 2020, 52 (01)
[8]  
E M., 2023, Meas. Sci. Technol., V34
[9]   A method to measure heat flux in convection using Gardon gauge [J].
Fu, Tairan ;
Zong, Anzhou ;
Zhang, Yirui ;
Wang, Hua Sheng .
APPLIED THERMAL ENGINEERING, 2016, 108 :1357-1361
[10]   High-Temperature Heat Flux Sensor Based on Tungsten-Rhenium Thin-Film Thermocouple [J].
Fu, Xiaoli ;
Lin, Qiyu ;
Peng, Yongqing ;
Liu, Jianhua ;
Yang, Xiaofei ;
Zhu, Benpeng ;
Ouyang, Jun ;
Zhang, Yue ;
Xu, Liangcai ;
Chen, Shi .