Impact of Beam Deflection Geometry on the Surface Architecture and Mechanical Properties of Electron-Beam-Modified TC4 Titanium Alloy

被引:0
作者
Ormanova, Maria [1 ]
Stoyanov, Borislav [2 ]
Nedyalkov, Nikolay [1 ]
Valkov, Stefan [1 ,3 ]
机构
[1] Bulgarian Acad Sci, Academician Emil Djakov Inst Elect, 72 Tsarigradsko Chaussee Blvd, Sofia 1784, Bulgaria
[2] Tech Univ Gabrovo, Dept Ind Desing & Text Engn, 4 H Dimitar Srt, Gabrovo 5300, Bulgaria
[3] Tech Univ Gabrovo, Dept Math Informat & Nat Sci, 4 H Dimitar Srt, Gabrovo 5300, Bulgaria
关键词
electron-beam modification; TC4 titanium alloy; beam deflection geometry; phase composition; structure; surface architecture; coefficient of friction; MICROSTRUCTURE; BIOMATERIALS; FRICTION;
D O I
10.3390/ma16155237
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper aims to investigate the impact of beam deflection geometry on the structure, surface architecture, and friction coefficient of electron-beam-modified TC4 titanium alloys. During the experiments, the electron beam was deflected in the form of different scanning geometries, namely linear, circular, and matrix. The structure of the treated specimens was investigated in terms of their phase composition by employing X-ray diffraction experiments. The microstructure was studied by scanning electron microscopy (SEM). The surface architecture was examined by atomic force microscopy (AFM). The friction coefficient was studied by a mechanical wear test. It was found that the linear and circular deflection geometries lead to a transformation of the phase composition, from double-phase & alpha; + & beta; to & alpha;' martensitic structure. The application of a linear manner of scanning leads to a residual amount of beta phase. The use of a matrix does not tend to structural changes on the surface of the TC4 alloy. In the case of linear geometry, the thickness of the modified zone is more than 800 & mu;m while, in the case of EBSM using circular scanning, the thickness is about 160 & mu;m. The electron-beam surface modification leads to a decrease in the surface roughness to about 27 nm in EBSM with linear deflection geometry and 31 nm in circular deflection geometry, compared to that of the pure TC4 substrate (about 160 nm). The electron-beam surface modification of the TC4 alloy leads to a decrease in the coefficient of friction (COF), with the lowest COF values obtained in the case of linear deflection geometry (0.32). The results obtained in this study show that beam deflection geometry has a significant effect on the surface roughness and friction coefficient of the treated surfaces. It was found that the application of a linear manner of scanning leads to the formation of a surface with the lowest roughness and friction coefficient.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Study of the influence of electron beam treatment of Ti5Al4V substrate on the mechanical properties and surface topography of multilayer TiN/TiO2 coatings
    Petrov, P.
    Dechev, D.
    Ivanov, N.
    Hikov, T.
    Valkov, S.
    Nikolova, M.
    Yankov, E.
    Parshorov, S.
    Bezdushnyi, R.
    Andreeva, A.
    [J]. VACUUM, 2018, 154 : 264 - 271
  • [32] Petrov P., 2010, Journal of Physics: Conference Series, V223, DOI 10.1088/1742-6596/223/1/012029
  • [33] Duplex Surface Modification of 304-L SS Substrates by an Electron-Beam Treatment and Subsequent Deposition of Diamond-like Carbon Coatings
    Rabadzhiyska, Stanislava
    Kotlarski, Georgi
    Shipochka, Maria
    Rafailov, Peter
    Ormanova, Maria
    Strijkova, Velichka
    Dimcheva, Nina
    Valkov, Stefan
    [J]. COATINGS, 2022, 12 (03)
  • [34] The Needs of Current Implant Technology in Orthopaedic Prosthesis Biomaterials Application to Reduce Prosthesis Failure Rate
    Rahyussalim, Ahmad Jabir
    Marsetio, Aldo Fransiskus
    Saleh, Ifran
    Kurniawati, Tri
    Whulanza, Yudan
    [J]. JOURNAL OF NANOMATERIALS, 2016, 2016
  • [35] Innovative surface modification of Ti6Al4V alloy by electron beam technique for biomedical application
    Ramskogler, Claudia
    Warchomicka, Fernando
    Mostofi, Sepideh
    Weinberg, Annelie
    Sommitsch, Christof
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 78 : 105 - 113
  • [36] Bio-tribological response of duplex surface engineered SS316L for hip-implant application
    Samanta, Aniruddha
    Rane, Ramkrishna
    Kundu, Biswanath
    Chanda, Dipak Kr
    Ghosh, Jiten
    Bysakh, Sandip
    Jhala, Ghanshyam
    Joseph, Alphonsa
    Mukherjee, Subroto
    Das, Mitun
    Mukhopadhyay, Anoop Kumar
    [J]. APPLIED SURFACE SCIENCE, 2020, 507
  • [37] Sasikumar Y., 2019, Journal of Bio- and Tribo-Corrosion, V5, P36, DOI [DOI 10.1007/S40735-019-0229-5, 10.1007/s40735-019-0229-5]
  • [38] Influence of surface preparation on roughness parameters, friction and wear
    Sedlacek, M.
    Podgornik, B.
    Vizintin, J.
    [J]. WEAR, 2009, 266 (3-4) : 482 - 487
  • [39] Laser micro & nano surface texturing for enhancing osseointegration and antimicrobial effect of biomaterials: A review
    Sirdeshmukh, Neelesh
    Dongre, Ganesh
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 2348 - 2355
  • [40] Stoyanova-Ivanova A., 2018, BULG CHEM COMMUN, V50, P73