Feasibility of clinical studies of chemical exchange saturation transfer magnetic resonance imaging of prostate cancer at 7 T

被引:1
|
作者
Reesink, Daan J. [1 ,6 ]
Arteaga de Castro, Catalina S. [2 ]
van der Velden, Tijl [2 ]
Van Vooren, Jeanette [3 ]
Oost, Petri [4 ]
Jonges, Trudy G. N. [5 ]
Lam, Marnix G. E. H. [3 ]
de Keizer, Bart [3 ]
Willemse, Peter-Paul M. [1 ]
Meijer, Richard P.
Klomp, Dennis W. J. [2 ]
机构
[1] Univ Med Ctr Utrecht, Dept Oncol Urol, Div Imaging & Oncol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Precis Imaging, Div Imaging & Oncol, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Radiol, Div Imaging & Oncol, Utrecht, Netherlands
[4] Tergooi Hosp Hilversum, Dept Urol, Hilversum, Netherlands
[5] Univ Med Ctr Utrecht, Dept Pathol, Utrecht, Netherlands
[6] Univ Med Ctr Utrecht, Dept Urol, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
关键词
7; T; diagnostic accuracy; high field; MRI; prostate cancer; COIL;
D O I
10.1002/nbm.4958
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Chemical exchange saturation transfer (CEST) has been explored for differentiation between tumour and benign tissue in prostate cancer (PCa) patients. With ultrahigh field strengths such as 7-T, the increase of spectral resolution and sensitivity could allow for selective detection of amide proton transfer (APT) at 3.5 ppm and a group of compounds that resonate at 2 ppm (i.e., [poly]amines and/or creatine). The potential of 7-T multipool CEST analysis of the prostate and the detection of PCa was studied in patients with proven localised PCa who were scheduled to undergo robot-assisted radical prostatectomy (RARP). Twelve patients were prospectively included (mean age 68.0 years, mean serum prostate-specific antigen 7.8ng/mL). A total of 24 lesions larger than 2 mm were analysed. Used were 7-T T2-weighted (T2W) imaging and 48 spectral CEST points. Patients received 1.5-T/3-T prostate magnetic resonance imaging and galium-68-prostate-specific membrane antigen-positron emission tomography/computerised tomography to determine the location of the single-slice CEST. Based on the histopathological results after RARP, three regions of interest were drawn on the T2W images from a known malignant zone and benign zone in the central and peripheral zones. These areas were transposed to the CEST data, from which the APT and 2-ppm CEST were calculated. The statistical significance of the CEST between the central zone, the peripheral zone, and tumour was calculated using a Kruskal-Wallis test. The z-spectra showed that APT and even a distinct pool that resonated at 2 ppm were detectable. This study showed a difference trend in the APT levels, but no difference in the 2-ppm levels when tested between the central zone, the peripheral zone, and tumour (H(2) = 4.8, p = 0.093 and H(2) = 0.86, p = 0.651, respectively). Thus, to conclude, we could most likely detect APT and amines and/or creatine levels noninvasively in prostate using the CEST effect. At group level, CEST showed a higher level of APT in the peripheral versus the central zone; however, no differences of APT and 2-ppm levels were observed in tumours.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Chemical exchange saturation transfer magnetic resonance imaging of human knee cartilage at 3 T and 7 T
    Singh, Anup
    Haris, Mohammad
    Cai, Kejia
    Kassey, Victor B.
    Kogan, Feliks
    Reddy, Damodar
    Hariharan, Hari
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 588 - 594
  • [2] Magnetic Resonance Imaging using Chemical Exchange Saturation Transfer
    Park, Jaeseok
    NANOSYSTEMS IN ENGINEERING AND MEDICINE, 2012, 8548
  • [3] Magnetic resonance chemical exchange saturation transfer imaging and nanotechnology
    Winter, Patrick M.
    WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2012, 4 (04) : 389 - 398
  • [4] Uniform magnetization transfer in chemical exchange saturation transfer magnetic resonance imaging
    Lee, Jae-Seung
    Parasoglou, Prodromos
    Xia, Ding
    Jerschow, Alexej
    Regatte, Ravinder R.
    SCIENTIFIC REPORTS, 2013, 3
  • [5] Uniform magnetization transfer in chemical exchange saturation transfer magnetic resonance imaging
    Jae-Seung Lee
    Prodromos Parasoglou
    Ding Xia
    Alexej Jerschow
    Ravinder R. Regatte
    Scientific Reports, 3
  • [6] Feasibility of Multiparametric Magnetic Resonance Imaging of the Prostate at 7 T
    Lagemaat, Miriam W.
    Philips, Bart W. J.
    Vos, Eline K.
    van Uden, Mark J.
    Futterer, Jurgen J.
    Jenniskens, Sjoerd F.
    Scheenen, Tom W. J.
    Maas, Marnix C.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (05) : 295 - 301
  • [7] Artificial intelligence in chemical exchange saturation transfer magnetic resonance imaging
    Swee Qi Pan
    Yan Chai Hum
    Khin Wee Lai
    Wun-She Yap
    Yi Zhang
    Hye-Young Heo
    Yee Kai Tee
    Artificial Intelligence Review, 58 (7)
  • [8] Chemical exchange saturation transfer contrast agents for magnetic resonance imaging
    Sherry, A. Dean
    Woods, Mark
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 : 391 - 411
  • [9] Chemical exchange saturation transfer magnetic resonance imaging and its main and potential applications in pre-clinical and clinical studies
    Dou, Weiqiang
    Lin, Chien-Yuan Eddy
    Ding, Hongyuan
    Shen, Yong
    Dou, Carol
    Qian, Long
    Wen, Baohong
    Wu, Bing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (10) : 1747 - 1766
  • [10] Preliminary application of 3.0 T magnetic resonance chemical exchange saturation transfer imaging in brain metastasis of lung cancer
    Yonggui Yang
    Xiaobo Qu
    Yihui Huang
    Khan Afsar
    Gen Yan
    Gang Guo
    Shaoyin Duan
    BMC Medical Imaging, 20