Structural Strengthening of Insufficiently Designed Reinforced Concrete T-Beams using CFRP Composites

被引:2
|
作者
Alobaidi, Hasan Ehssan [1 ]
Al-Zuhairi, Alaa Hussein [1 ]
机构
[1] Univ Baghdad, Dept Civil Engn, Fac Engn, Baghdad 10071, Iraq
来源
CIVIL ENGINEERING JOURNAL-TEHRAN | 2023年 / 9卷 / 08期
关键词
T-Beams; CFRP Composites; Bending Stresses; Shear Stresses; BEHAVIOR; BOND;
D O I
10.28991/CEJ-2023-09-08-05
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to compare the response of reinforced concrete (RC) T-beams strengthened with carbon fibre-reinforced polymer (CFRP) composite with that of non-strengthened control beams when subjected to monotonic two-point loading until failure for flexural once and shear again. The experimental programme tested eight RC T-beams, which included two reference beams without strengthening and six strengthened beams. The eight beams were divided into two main groups according to strengthening (flexural and shear). Experimental analysis was performed to study the effect of the CFRP laminate width in the flexural group and the spacing of CFRP U-wrap sheets in the shear group on the ultimate load capacity, load-strain relationship, and load-deflection relationship. Results show that increasing the width of the CFRP laminate in the flexural group improves the ultimate strengths to approximately 9.5%, 35%, and 41% for beams with CFRP laminate widths of 50, 100, and 150 mm, respectively, compared with the reference non-strengthened beam. The stiffness of the beams increases in direct proportion to the width of the CFRP laminate. In the meantime, decreasing the spacing of the CFRP laminate in the shear group increases the ultimate strengths to approximately 13.2%, 17.7%, and 23.5% for beams with CFRP U-wrap sheet spacings of 166, 125, and 100 mm, respectively, compared with the reference non-strengthened beam. Therefore, the spacing of the CFRP sheet is inversely proportional to the stiffness of the beam.
引用
收藏
页码:1880 / 1896
页数:17
相关论文
共 50 条
  • [41] A smeared crack analysis of reinforced concrete T-beams strengthened with GFRP composites
    Biscaia, Hugo C.
    Chastre, Carlos
    Silva, Manuel A. G.
    ENGINEERING STRUCTURES, 2013, 56 : 1346 - 1361
  • [42] Strengthening of Reinforced Concrete Beams via CFRP Orientation
    Uz, Mehmet Eren
    Guner, Yunus
    Avci, Esra
    BUILDINGS, 2024, 14 (01)
  • [43] Flexural behavior experiment of reinforced concrete T-beams with steel plate-concrete composite strengthening
    Wang, Chun-Sheng
    Yuan, Zhuo-Ya
    Guo, Xiao-Yu
    Gao, Shan
    Ren, Teng-Xian
    Jiaotong Yunshu Gongcheng Xuebao/Journal of Traffic and Transportation Engineering, 2010, 10 (06): : 32 - 40
  • [44] Optimum Configuration of CFRP Composites for Strengthening of Reinforced Concrete Beams Considering the Contact Constraint
    Amaireh, Layla K.
    Al-Tamimi, Ahmad
    1ST INTERNATIONAL CONFERENCE ON OPTIMIZATION-DRIVEN ARCHITECTURAL DESIGN (OPTARCH 2019), 2020, 44 : 350 - 357
  • [45] Experimental Investigation of Reinforced Concrete T-Beams Strengthened in Shear with Externally Bonded CFRP Sheets
    Foster, Robert M.
    Brindley, Monika
    Lees, Janet M.
    Ibell, Tim J.
    Morley, Chris T.
    Darby, Antony P.
    Evernden, Mark C.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (02)
  • [46] Flexural-strengthening efficiency of cfrp sheets for unbonded post-tensioned concrete T-beams
    Long Nguyen-Minh
    Phuong Phan-Vu
    Duong Tran-Thanh
    Quynh Phuong Thi Truong
    Pham, Thong M.
    Cuong Ngo-Huu
    Rovnak, Marian
    ENGINEERING STRUCTURES, 2018, 166 : 1 - 15
  • [47] New Proposal for Flexural Strengthening of Reinforced Concrete Beams Using CFRP T-Shaped Profiles
    Kotynia, Renata
    Cholostiakow, Szymon
    POLYMERS, 2015, 7 (11) : 2461 - 2477
  • [48] Shear strengthening of reinforced concrete T-beams under cyclic loading with TRM or FRP jackets
    Department of Civil Engineering, University of Patras, Patras
    26500, Greece
    Mater Struct, 1600, 1-2 (17-28):
  • [49] Shear strengthening of reinforced concrete T-beams under cyclic loading with TRM or FRP jackets
    Tzoura, E.
    Triantafillou, T. C.
    MATERIALS AND STRUCTURES, 2016, 49 (1-2) : 17 - 28
  • [50] Shear strengthening of reinforced concrete T-beams under cyclic loading with TRM or FRP jackets
    E. Tzoura
    T. C. Triantafillou
    Materials and Structures, 2016, 49 : 17 - 28