Fan beam CT image synthesis from cone beam CT image using nested residual UNet based conditional generative adversarial network

被引:3
作者
Joseph, Jiffy [1 ]
Biji, Ivan [1 ]
Babu, Naveen [1 ]
Pournami, P. N. [1 ]
Jayaraj, P. B. [1 ]
Puzhakkal, Niyas [2 ]
Sabu, Christy [1 ]
Patel, Vedkumar [1 ]
机构
[1] Natl Inst Technol Calicut, Comp Sci & Engn Dept, Calicut 673601, Kerala, India
[2] MVR Canc Ctr & Res Inst, Dept Med Phys, Calicut 673601, Kerala, India
关键词
Conditional generative adversarial network; Cone beam CT; Fan beam CT; Image synthesis; COMPUTED-TOMOGRAPHY; NOISE;
D O I
10.1007/s13246-023-01244-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A radiotherapy technique called Image-Guided Radiation Therapy adopts frequent imaging throughout a treatment session. Fan Beam Computed Tomography (FBCT) based planning followed by Cone Beam Computed Tomography (CBCT) based radiation delivery drastically improved the treatment accuracy. Furtherance in terms of radiation exposure and cost can be achieved if FBCT could be replaced with CBCT. This paper proposes a Conditional Generative Adversarial Network (CGAN) for CBCT-to-FBCT synthesis. Specifically, a new architecture called Nested Residual UNet (NR-UNet) is introduced as the generator of the CGAN. A composite loss function, which comprises adversarial loss, Mean Squared Error (MSE), and Gradient Difference Loss (GDL), is used with the generator. The CGAN utilises the inter-slice dependency in the input by taking three consecutive CBCT slices to generate an FBCT slice. The model is trained using Head-and-Neck (H&N) FBCT-CBCT images of 53 cancer patients. The synthetic images exhibited a Peak Signal-to-Noise Ratio of 34.04 +/- 0.93 dB, Structural Similarity Index Measure of 0.9751 +/- 0.001 and a Mean Absolute Error of 14.81 +/- 4.70 HU. On average, the proposed model guarantees an improvement in Contrast-to-Noise Ratio four times better than the input CBCT images. The model also minimised the MSE and alleviated blurriness. Compared to the CBCT-based plan, the synthetic image results in a treatment plan closer to the FBCT-based plan. The three-slice to single-slice translation captures the three-dimensional contextual information in the input. Besides, it withstands the computational complexity associated with a three-dimensional image synthesis model. Furthermore, the results demonstrate that the proposed model is superior to the state-of-the-art methods.
引用
收藏
页码:703 / 717
页数:15
相关论文
共 52 条
[1]  
Agarap A.F., 2018, ABS180308375 CORR
[2]   MedGAN: Medical image translation using GANs [J].
Armanious, Karim ;
Jiang, Chenming ;
Fischer, Marc ;
Kuestner, Thomas ;
Nikolaou, Konstantin ;
Gatidis, Sergios ;
Yang, Bin .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2020, 79
[3]   Comparison of CBCT-based dose calculation methods in head and neck cancer radiotherapy: from Hounsfield unit to density calibration curve to deep learning [J].
Barateau, Anais ;
De Crevoisier, Renaud ;
Largent, Axel ;
Mylona, Eugenia ;
Perichon, Nicolas ;
Castelli, Joel ;
Chajon, Enrique ;
Acosta, Oscar ;
Simon, Antoine ;
Nunes, Jean-Claude ;
Lafond, Caroline .
MEDICAL PHYSICS, 2020, 47 (10) :4683-4693
[4]   Synthetic CT generation from CBCT images via deep learning [J].
Chen, Liyuan ;
Liang, Xiao ;
Shen, Chenyang ;
Jiang, Steve ;
Wang, Jing .
MEDICAL PHYSICS, 2020, 47 (03) :1115-1125
[5]   Intensity non-uniformity correction in MR imaging using residual cycle generative adversarial network [J].
Dai, Xianjin ;
Lei, Yang ;
Liu, Yingzi ;
Wang, Tonghe ;
Ren, Lei ;
Curran, Walter J. ;
Patel, Pretesh ;
Liu, Tian ;
Yang, Xiaofeng .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21)
[6]   Image Synthesis in Multi-Contrast MRI With Conditional Generative Adversarial Networks [J].
Dar, Salman U. H. ;
Yurt, Mahmut ;
Karacan, Levent ;
Erdem, Aykut ;
Erdem, Erkut ;
Cukur, Tolga .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (10) :2375-2388
[7]   Deep learning-based MR-to-CT synthesis: The influence of varying gradient echo-based MR images as input channels [J].
Florkow, Mateusz C. ;
Zijlstra, Frank ;
Willemsen, Koen ;
Maspero, Matteo ;
van den Berg, Cornelis A. T. ;
Kerkmeijer, Linda G. W. ;
Castelein, Rene M. ;
Weinans, Harrie ;
Viergever, Max A. ;
van Stralen, Marijn ;
Seevinck, Peter R. .
MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) :1429-1441
[8]   Deep Residual Inception Encoder-Decoder Network for Medical Imaging Synthesis [J].
Gao, Fei ;
Wu, Teresa ;
Chu, Xianghua ;
Yoon, Hyunsoo ;
Xu, Yanzhe ;
Patel, Bhavika .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (01) :39-49
[9]  
Goodfellow IJ, 2014, ADV NEUR IN, V27, P2672
[10]   Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography [J].
Harms, Joseph ;
Lei, Yang ;
Wang, Tonghe ;
Zhang, Rongxiao ;
Zhou, Jun ;
Tang, Xiangyang ;
Curran, Walter J. ;
Liu, Tian ;
Yang, Xiaofeng .
MEDICAL PHYSICS, 2019, 46 (09) :3998-4009