Muscle Belly Repair: Biomechanical Assessment of the Anchor Suture and the Modified Kessler Techniques

被引:0
作者
Julien, Terrill P. [1 ]
Li, Guoan [2 ]
Mudgal, Chaitanya S. [3 ,4 ]
机构
[1] Midatlantic Permanente Med Grp, Dept Orthopaed Surg, Dist Columbia & Southern Maryland, Rockville, MD USA
[2] Harvard Med Sch, Newton Wellesley Hosp, Orthopaed Bioengn Lab, Newton, MA USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Orthopaed Hand Serv, Orthopaed Surg, Boston, MA USA
[4] Massachusetts Gen Hosp, Yawkey Ctr, Orthopaed Hand Serv, Suite 2100,55 Fruit St, Boston, MA 02114 USA
关键词
Muscle; Belly; Laceration; Repair; Technique; PECTORALIS MAJOR MUSCLE; TRAUMATIC CLOSED TRANSECTION; SURGICAL REPAIR; RUPTURE; LACERATION; INJURIES;
D O I
10.1142/S2424835523500583
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Treatment of muscle belly lacerations remains a problem for surgeons. Inadequate repair of lacerations can cause functional disability. To date, there is no consensus on the method of repair for these injuries. We have previously described a technique of repairing mid-substance muscle belly lacerations. The aim of this study was to determine the ultimate strength of an intact muscle belly and to compare the anchor suture (AS) technique with the modified Kessler (MK) technique.Methods: Fifteen fresh frozen hind-legs from adolescent pigs were divided into three groups and used for the testing. Each group consisted of five specimens. Group one was the intact control group, group two was repaired with the MK technique and group three was repaired with the AS technique. Following repair, the muscles were secured in a custom-made fixation apparatus and underwent linear tensioning at a rate of 25 mm/min, generating a load-displacement curve for each specimen. The data regarding ultimate strength, modes of failure and number of intact suture/anchor constructs (for groups 2 and 3) was calculated.Results: The ultimate strength of the intact muscle group of was found to be 608.1 +/- 107.9 N. This was significantly (p < 0.05) higher than the pull-out strength of the MK and AS groups. The pull-out strength of the AS group was 143.1 +/- 36.7 N, nearly twice that of the MK group 69.8 +/- 16.4 N (p = 0.11). Suture pull-out was the most common mode of failure.Conclusions: The AS technique was found to have both higher strain and nearly twice the ultimate pull-out strength compared to the MK repair group. We suggest the AS technique as a viable technique for mid-substance muscle belly repairs.
引用
收藏
页码:513 / 521
页数:9
相关论文
共 39 条
  • [21] The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair
    Wieskoetter, B.
    Herbort, M.
    Langer, M.
    Raschke, M. J.
    Waehnert, D.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (01) : 139 - 145
  • [22] Comparing 3 Suture Techniques After Muscle Laceration Repair
    Castillo, Alexander C.
    Kaltwasser, Kyle
    Morris, Randal
    Sanchez, Erick R.
    Rai, Surjit
    Lombana, Nicholas
    Tran, Dat
    Branski, Ludwik
    Zhang, Andrew Y.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (01): : 67 - 72
  • [23] Biomechanical comparisons of three minimally invasive Achilles tendon percutaneous repair suture techniques
    Melcher, C.
    Renner, C.
    Piepenbrink, M.
    Fischer, N.
    Buettner, A.
    Wegener, V.
    Birkenmaier, C.
    Jansson, V.
    Wegener, B.
    CLINICAL BIOMECHANICS, 2022, 92
  • [24] Arthroscopic Repair of Triangular Fibrocartilage Tears: A Biomechanical Comparison of a Knotless Suture Anchor and the Traditional Outside-In Repairs
    Desai, Mihir J.
    Hutton, William C.
    Jarrett, Claudius D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (11): : 2193 - 2197
  • [25] Comparison of Suture Types and Techniques in Achilles Tendon Repair An Ex Vivo Biomechanical Animal Experiment
    Dogar, Fatih
    Gurbuz, Kaan
    Topak, Duran
    Ozdemir, Mustafa Abdullah
    Kuscu, Burak
    Ekinci, Yakup
    Batin, Sabri
    Yaykasli, Hakan
    Bilal, Okkes
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2024, 114 (02)
  • [26] Biomechanical Properties of Double- and Single-Row Suture Anchor Repair for Surgical Treatment of Insertional Achilles Tendinopathy
    Beitzel, Knut
    Mazzocca, Augustus D.
    Obopilwe, Elifho
    Boyle, James W.
    McWilliam, James
    Rincon, Lina
    Dhar, Yasmin
    Arciero, Robert A.
    Amendola, Annunziato
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (07) : 1642 - 1648
  • [27] Comparison of an All-Inside Suture Technique With Traditional Pull-Out Suture and Suture Anchor Repair Techniques for Flexor Digitorum Profundus Attachment to Bone
    Chu, Jennifer Y.
    Chen, Tony
    Awad, Hani A.
    Elfar, John
    Hammert, Warren C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (06): : 1084 - 1090
  • [28] Ex vivo biomechanical evaluation and comparison of lateral femoro-fabella ligament suture and lateral suture with bone anchor for cranial cruciate ligament repair in cats
    Tassani, Chiara
    de Witt, Anika A.
    Fosgate, Geoffrey T.
    Elliott, Ross C.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2024, 85 (08)
  • [29] Comparison of clinical, biomechanical, and histopathological effects of various suture techniques on repair of tendon rupture by using autograft
    Ermutlu, Celal Sahin
    Baran, Vedat
    JOURNAL OF VETERINARY RESEARCH, 2017, 61 (02) : 231 - 237
  • [30] A biomechanical study of pediatric flexor profundus tendon repair Comparing the tensile strengths of 3 suture techniques
    Al-Thunayan, Turki A.
    Al-Zahrani, Mohammed T.
    Hakeem, Ahmad A.
    Al-Zahrani, Fahad M.
    Al-Qattan, Mohammad M.
    SAUDI MEDICAL JOURNAL, 2016, 37 (09) : 957 - 962