Posterior wall thickness of the confluent inferior pulmonary veins measured by left atrial intracardiac echocardiography: implications for catheter ablation

被引:2
作者
Negishi, Kodai [1 ]
Okumura, Ken [1 ]
Onishi, Fumitaka [1 ]
Yoshimura, Akino [1 ]
Okamatsu, Hideharu [1 ]
Tsurugi, Takuo [1 ]
Tanaka, Yasuaki [1 ]
Sakai, Yoshiro [1 ]
Nakao, Koichi [1 ]
Sakamoto, Tomohiro [1 ]
Koyama, Junjiro [1 ]
Tomita, Hirofumi [2 ]
机构
[1] Saiseikai Kumamoto Hosp, Cardiovasc Ctr, Div Cardiol, 5-3-1 Chikami,Minami Ku, Kumamoto 8614193, Japan
[2] Hirosaki Univ, Dept Cardiol & Nephrol, Grad Sch Med, Hirosaki, Japan
关键词
Confluent inferior pulmonary veins; Atrial fibrillation; Intracardiac echocardiography; Catheter ablation; COMMON OSTIUM; VARIANT; TRUNK; CT;
D O I
10.1007/s10840-023-01613-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundConfluent inferior pulmonary veins (CIPV) is a rare anatomical variant. There is few evidence in the literature regarding anatomic landmarks consideration to guide radiofrequency application in avoiding complications in the esophagus in CIPV cases.MethodsOf 986 consecutive patients undergoing atrial fibrillation (AF) ablation from July 2020 to June 2022, seven (0.7%) had CIPV with a common trunk connecting to the LA diagnosed by 3-dimensional contrast-enhanced computed tomography. Using intracardiac echocardiography (ICE) performed from the left atrium (LA), we measured the posterior wall thickness (PWT) of the CIPV adjacent to the esophagus and compared the measurement with the LA posterior wall thickness (LAPWT) at the left inferior PV level of 25 controls without CIPV. For ablation in CIPV patients, each superior PV was individually isolated, and box isolation of CIPV without ablating the CIPV posterior wall was added (tri-circle ablation technique).ResultsThe CIPV PWT was 0.7 & PLUSMN; 0.1 mm, while non-CIPV LAPWT was 2.0 & PLUSMN; 0.4 mm (P < 0.001). In the CIPV group, upper and lower portions of the CIPV were both apart from the esophagus (mean distances, 6.7 & PLUSMN; 3.4 mm and 7.9 & PLUSMN; 2.7 mm, respectively). Individual superior PV isolation and box CIPV isolation resulted in complete isolation of all PVs, with no complications. All CIPV patients except one remained AF recurrence-free for 376 & PLUSMN; 52 days.ConclusionsAlthough CIPV frequency is low, CIPV PWT is very thin and special care is needed during ablation. A "tri-circle" ablation strategy avoids ablating in the thinnest portion of the posterior wall. Further studies are warranted to assess the safety.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 19 条
[11]   Pulsed field ablation in common inferior pulmonary trunk [J].
Mittal, Ashish ;
Fitzpatrick, Noel ;
Szeplaki, Gabor .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) :809-810
[12]   High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation [J].
Okamatsu, Hideharu ;
Koyama, Junjiro ;
Sakai, Yoshirou ;
Negishi, Koudai ;
Hayashi, Katsuhide ;
Tsurugi, Takuo ;
Tanaka, Yasuaki ;
Nakao, Koichi ;
Sakamoto, Tomohiro ;
Okumura, Ken .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) :2751-2758
[13]   Anomalous Midline Common Ostium of the Left and Right Inferior Pulmonary Veins Implications for Pulmonary Vein Isolation in Atrial Fibrillation [J].
Patel, Ashit G. ;
Clark, Tom ;
Oliver, Ronald ;
stecker, Eric C. ;
Shapiro, Michael D. ;
Stajiduhar, Karl ;
Kron, Jack ;
McAnulty, John H., Jr. ;
Chugh, Sumeet S. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2008, 1 (05) :407-408
[14]  
Providencia Rui, 2013, Europace, V15, P1420, DOI 10.1093/europace/eut137
[15]   Changes in local wall thickness correlate with pathologic lesion size following radiofrequency catheter ablation: An intracardiac echocardiographic imaging study [J].
Ren, JF ;
Callans, DJ ;
Schwartzman, D ;
Michele, JJ ;
Marchlinski, FE .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (06) :503-507
[16]   Common pulmonary venous ostium of the right and left inferior pulmonary veins: An unusual pulmonary vein anomaly depicted with 64-slice cardiac computed tomography [J].
Shapiro, Michael ;
Dodd, Jonathan D. ;
Brady, Thomas J. ;
Abbara, Suhny .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (01) :110-110
[17]   The role of myocardial wall thickness in atrial arrhythmogenesis [J].
Whitaker, John ;
Rajani, Ronak ;
Chubb, Henry ;
Gabrawi, Mark ;
Varela, Marta ;
Wright, Matthew ;
Niederer, Steven ;
O'Neill, Mark D. .
EUROPACE, 2016, 18 (12) :1758-1772
[18]   Prevalence, morphological and electrophysiological characteristics of confluent inferior pulmonary veins in patients with atrial fibrillation [J].
Yamane, Teiichi ;
Date, Taro ;
Tokuda, Michifumi ;
Aramaki, Yasuko ;
Inada, Keiichi ;
Matsuo, Seiichiro ;
Shibayama, Kenri ;
Miyanaga, Satoru ;
Miyazaki, Hidekazu ;
Sugimoto, Ken-ichi ;
Sakuma, Tohru ;
Fukuda, Kunihiko ;
Mochizuki, Seibu ;
Yoshimura, Michihiro .
CIRCULATION JOURNAL, 2008, 72 (08) :1285-1290
[19]  
Yu RH, 2008, PACE, V31, P93, DOI 10.1111/j.1540-8159.2007.00931.x