Reducing both radiation and contrast doses for overweight patients in coronary CT angiography with 80-kVp and deep learning image reconstruction

被引:4
|
作者
Li, Wanjiang [1 ]
Lu, Haiyan [2 ]
Wen, Yuting [1 ]
Zhou, Minggang [3 ]
Shuai, Tao [1 ]
You, Yongchun [1 ]
Zhao, Jin [1 ]
Liao, Kai [1 ]
Lu, Chunyan [1 ]
Li, Jianying [4 ]
Li, Zhenlin [1 ]
Diao, Kaiyue [1 ,5 ]
He, Yong [3 ,6 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Radiol, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Resp & Crit Care Med, Chengdu, Peoples R China
[3] Sichuan Univ, West China Hosp, Dept Cardiol, Chengdu, Sichuan, Peoples R China
[4] CT Res Ctr, GE Healthcare, Beijing, Peoples R China
[5] Sichuan Univ, West China Hosp, Dept Radiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
[6] Sichuan Univ, West China Hosp, Dept Cardiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
关键词
Computed tomography; Coronary CT angiography; Radiation dose; Contrast dose; Deep -learning image reconstruction; TUBE VOLTAGE; ITERATIVE RECONSTRUCTION; SCCT GUIDELINES; QUALITY; OBESITY; RISK; BMI;
D O I
10.1016/j.ejrad.2023.110736
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the use of an 80-kVp tube voltage combined with a deep learning image reconstruction (DLIR) algorithm in coronary CT angiography (CCTA) for overweight patients to reduce radiation and contrast doses in comparison with the 120-kVp protocol and adaptive statistical iterative reconstruction (ASIR-V). Methods: One hundred consecutive CCTA patients were prospectively enrolled and randomly divided into a low -dose group (n = 50) with 80-kVp, smart mA for noise index (NI) of 36 HU, contrast dose rate of 18 mgI/kg/s and DLIR and 60 % ASIR-V and a standard-dose group (n = 50) with 120-kVp, smart mA for NI of 25 HU, contrast dose rate of 32 mgI/kg/s and 60 % ASIR-V. The radiation and contrast dose, subjective image quality score, attenuation values, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared. Results: The low-dose group achieved a significant reduction in the effective radiation dose (1.01 +/- 0.45 mSv vs 1.85 +/- 0.40 mSv, P < 0.001) and contrast dose (33.69 +/- 3.87 mL vs 59.11 +/- 5.60 mL, P < 0.001) compared to the standard-dose group. The low-dose group with DLIR presented similar enhancement but lower noise, higher SNR and CNR and higher subjective quality scores than the standard-dose group. Moreover, the same patient comparison in the low-dose group between different reconstructions showed that DLIR images had slightly and consistently higher CT values in small vessels, indicating better defined vessels, much lower image noise, higher SNR and CNR and higher subjective quality scores than ASIR-V images (all P < 0.001). Conclusions: The application of 80-kVp and DLIR allows for significant radiation and dose reduction while further improving image quality in CCTA for overweight patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] CT angiography of the aorta using 80kVp in combination with sinogram-affirmed iterative reconstruction and automated tube current modulation: Effects on image quality and radiation dose
    Boos, Johannes
    Aissa, Joel
    Lanzman, Rotem S.
    Heusch, Philipp
    Schimmoeller, Lars
    Schleich, Christoph
    Thomas, Christoph
    Antoch, Gerald
    Kroepil, Patric
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (02) : 187 - 193
  • [42] High-Pitch Coronary CT Angiography at 70 kVp With Low Contrast Medium Volume Comparison of 80 and 100 kVp High-Pitch Protocols
    Zhang, Long Jiang
    Qi, Li
    De Cecco, Carlo N.
    Zhou, Chang Sheng
    Spearman, James V.
    Schoepf, U. Joseph
    Lu, Guang Ming
    MEDICINE, 2014, 93 (22)
  • [43] Improving image quality with super-resolution deep-learning-based reconstruction in coronary CT angiography
    Nagayama, Yasunori
    Emoto, Takafumi
    Kato, Yuki
    Kidoh, Masafumi
    Oda, Seitaro
    Sakabe, Daisuke
    Funama, Yoshinori
    Nakaura, Takeshi
    Hayashi, Hidetaka
    Takada, Sentaro
    Uchimura, Ryutaro
    Hatemura, Masahiro
    Tsujita, Kenichi
    Hirai, Toshinori
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 8488 - 8500
  • [44] Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies
    Jeon, Pil-Hyun
    Jeon, Sang-Hyun
    Ko, Donghee
    An, Giyong
    Shim, Hackjoon
    Otgonbaatar, Chuluunbaatar
    Son, Kihong
    Kim, Daehong
    Ko, Sung Min
    Chung, Myung-Ae
    DIAGNOSTICS, 2023, 13 (11)
  • [45] Achieving low radiation dose and contrast agents dose in coronary CT angiography at 60-kVp ultra-low tube voltage
    He, Weiling
    Huang, Feng
    Wu, Xi
    Xie, An
    Sun, Wenjie
    Liu, Peng
    Hu, Rui
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [46] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [47] Improved image quality and low radiation dose with hybrid iterative reconstruction with 80 kV CT pulmonary angiography
    Laqmani, Azien
    Regier, Marc
    Veldhoen, Simon
    Backhaus, Alexandra
    Wassenberg, Felicia
    Sehner, Susanne
    Groth, Michael
    Nagel, Hans-Dieter
    Adam, Gerhard
    Henes, Frank O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1962 - 1969
  • [48] Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection
    Wang, Rui
    Schoepf, U. Joseph
    Wu, Runze
    Reddy, Ryan P.
    Zhang, Chuanchen
    Yu, Wei
    Liu, Yi
    Zhang, Zhaoqi
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3141 - 3145
  • [49] CT enterography at 100 kVp with iterative reconstruction compared to 120 kVp filtered back projection: evaluation of image quality and radiation dose in the same patients
    Evan Johnson
    Alec J. Megibow
    Natasha E. Wehrli
    Thomas O’Donnell
    Hersh Chandarana
    Abdominal Imaging, 2014, 39 : 1255 - 1260
  • [50] Improved image quality with simultaneously reduced radiation exposure: Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting
    Andre, Florian
    Fortner, Philipp
    Vembar, Mani
    Mueller, Dirk
    Stiller, Wolfram
    Buss, Sebastian J.
    Kauczor, Hans-Ulrich
    Katus, Hugo A.
    Korosoglou, Grigorios
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (03) : 213 - 220