Reducing both radiation and contrast doses for overweight patients in coronary CT angiography with 80-kVp and deep learning image reconstruction

被引:4
|
作者
Li, Wanjiang [1 ]
Lu, Haiyan [2 ]
Wen, Yuting [1 ]
Zhou, Minggang [3 ]
Shuai, Tao [1 ]
You, Yongchun [1 ]
Zhao, Jin [1 ]
Liao, Kai [1 ]
Lu, Chunyan [1 ]
Li, Jianying [4 ]
Li, Zhenlin [1 ]
Diao, Kaiyue [1 ,5 ]
He, Yong [3 ,6 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Radiol, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Resp & Crit Care Med, Chengdu, Peoples R China
[3] Sichuan Univ, West China Hosp, Dept Cardiol, Chengdu, Sichuan, Peoples R China
[4] CT Res Ctr, GE Healthcare, Beijing, Peoples R China
[5] Sichuan Univ, West China Hosp, Dept Radiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
[6] Sichuan Univ, West China Hosp, Dept Cardiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
关键词
Computed tomography; Coronary CT angiography; Radiation dose; Contrast dose; Deep -learning image reconstruction; TUBE VOLTAGE; ITERATIVE RECONSTRUCTION; SCCT GUIDELINES; QUALITY; OBESITY; RISK; BMI;
D O I
10.1016/j.ejrad.2023.110736
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the use of an 80-kVp tube voltage combined with a deep learning image reconstruction (DLIR) algorithm in coronary CT angiography (CCTA) for overweight patients to reduce radiation and contrast doses in comparison with the 120-kVp protocol and adaptive statistical iterative reconstruction (ASIR-V). Methods: One hundred consecutive CCTA patients were prospectively enrolled and randomly divided into a low -dose group (n = 50) with 80-kVp, smart mA for noise index (NI) of 36 HU, contrast dose rate of 18 mgI/kg/s and DLIR and 60 % ASIR-V and a standard-dose group (n = 50) with 120-kVp, smart mA for NI of 25 HU, contrast dose rate of 32 mgI/kg/s and 60 % ASIR-V. The radiation and contrast dose, subjective image quality score, attenuation values, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared. Results: The low-dose group achieved a significant reduction in the effective radiation dose (1.01 +/- 0.45 mSv vs 1.85 +/- 0.40 mSv, P < 0.001) and contrast dose (33.69 +/- 3.87 mL vs 59.11 +/- 5.60 mL, P < 0.001) compared to the standard-dose group. The low-dose group with DLIR presented similar enhancement but lower noise, higher SNR and CNR and higher subjective quality scores than the standard-dose group. Moreover, the same patient comparison in the low-dose group between different reconstructions showed that DLIR images had slightly and consistently higher CT values in small vessels, indicating better defined vessels, much lower image noise, higher SNR and CNR and higher subjective quality scores than ASIR-V images (all P < 0.001). Conclusions: The application of 80-kVp and DLIR allows for significant radiation and dose reduction while further improving image quality in CCTA for overweight patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography
    Yuan, Dian
    Wang, Luotong
    Lyu, Peijie
    Zhang, Yonggao
    Gao, Jianbo
    Liu, Jie
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (06): : 1377 - 1388
  • [22] Super-Resolution Deep Learning Reconstruction for Improved Image Quality of Coronary CT Angiography
    Takafuji, Masafumi
    Kitagawa, Kakuya
    Mizutani, Sachio
    Hamaguchi, Akane
    Kisou, Ryosuke
    Iio, Kotaro
    Ichikawa, Kazuhide
    Izumi, Daisuke
    Sakuma, Hajime
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (04):
  • [23] Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography
    Chen, Guo Zhong
    Zhang, Long Jiang
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Milliken, Cole M.
    Zhou, Chang Sheng
    Qi, Li
    Luo, Song
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1453 - 1463
  • [24] Image quality of coronary CT angiography at ultra low tube voltage reconstructed with a deep-learning image reconstruction algorithm in patients of different weight
    Zhu, Lijuan
    Ha, Ruoshui
    Machida, Haruhiko
    Shi, Xiaomeng
    Wang, Fang
    Chen, Kemin
    Chen, Dazhi
    Cao, Yongpei
    Shen, Yun
    Yang, Lili
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (06) : 3891 - 3901
  • [25] Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography
    Guo Zhong Chen
    Long Jiang Zhang
    U. Joseph Schoepf
    Julian L. Wichmann
    Cole M. Milliken
    Chang Sheng Zhou
    Li Qi
    Song Luo
    Guang Ming Lu
    European Radiology, 2015, 25 : 1453 - 1463
  • [26] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [27] Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review
    Abdullah, Kamarul Amin
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 459 - 468
  • [28] CT enterography at 100 kVp with iterative reconstruction compared to 120 kVp filtered back projection: evaluation of image quality and radiation dose in the same patients
    Johnson, Evan
    Megibow, Alec J.
    Wehrli, Natasha E.
    O'Donnell, Thomas
    Chandarana, Hersh
    ABDOMINAL IMAGING, 2014, 39 (06): : 1255 - 1260
  • [29] Deep learning-based image restoration algorithm for coronary CT angiography
    Tatsugami, Fuminari
    Higaki, Toru
    Nakamura, Yuko
    Yu, Zhou
    Zhou, Jian
    Lu, Yujie
    Fujioka, Chikako
    Kitagawa, Toshiro
    Kihara, Yasuki
    Iida, Makoto
    Awai, Kazuo
    EUROPEAN RADIOLOGY, 2019, 29 (10) : 5322 - 5329
  • [30] Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction
    Brady, Samuel L.
    Trout, Andrew T.
    Somasundaram, Elanchezhian
    Anton, Christopher G.
    Li, Yinan
    Dillman, Jonathan R.
    RADIOLOGY, 2021, 298 (01) : 180 - 188