A comprehensive assessment approach to quantify the energy and economic performance of small-scale solar homestay hotel systems

被引:10
作者
Luo, Jianing [1 ]
Zhuang, Chaoqun [2 ]
Liu, Jianwei [3 ,4 ]
Lai, Kee -hung [4 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
[2] Alan Turing Inst, Data Cent Engn, London, England
[3] Dalian Univ Technol, Sch Econ & Management, Dalian, Peoples R China
[4] Hong Kong Polytech Univ, Fac Business, Dept Logist & Maritime Studies, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar homestay hotel; Dynamic occupancy rate; Break-even analysis; Economic and energy performance; Renewable energy penetration; LEVELIZED COST; CONSUMPTION; ATRIUM;
D O I
10.1016/j.enbuild.2022.112675
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the tourism industry, hotels and homestay facilities account for considerable amounts of energy con-sumption and CO2 emissions. Unlike other types of buildings, occupancy has significant fluctuations over time, while mostly being ignored or using a simple assumption based on energy use intensity or setting the occupancy levels. Due to the lack of occupancy rate information, great uncertainties exist in hotel operations, which leads to erroneous estimates of energy consumption in existing hotel buildings. This paper examines hotel operation practices in China with real occupancy rate data which is critical for reducing the uncertainty of estimating energy consumption patterns. Specifically, this study proposes a two-stage comprehensive and quantitative performance assessment approach for the homestay hotel building considering the system's energy and economic performance simultaneously. Regarding energy performance, there are two key facets to consider: renewable energy penetration and grid impact perfor-mance. Additionally, the economic performance (annual income and extra annual investment) of various energy portfolios is evaluated using break-even analysis. The impacts of large fluctuation in occupancy rate on electrical loads are considered and assessed in typical homestay hotels. The proposed assessment approach can comprehensively quantify the impacts of the photovoltaics (PV) areas and battery capaci-ties on the system performance in terms of energy and economics. According to the results of the occupancy-based assessment, the ideal PV area and battery capacity are 400 m2 and 16 kWh, respec-tively, as opposed to the optimal energy portfolios (PV area 600 m2 and battery capacity 24 kWh) deter-mined from conventional assessment results.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 42 条
  • [1] Performance and cost evaluation of solar dish power plant: sensitivity analysis of levelized cost of electricity (LCOE) and net present value (NPV)
    Abdelhady, Suzan
    [J]. RENEWABLE ENERGY, 2021, 168 : 332 - 342
  • [2] Comparative analysis of energy performance between courtyard and atrium in buildings
    Aldawoud, Abdelsalam
    Clark, Ray
    [J]. ENERGY AND BUILDINGS, 2008, 40 (03) : 209 - 214
  • [3] Asvanyi K., 2017, J ENV MANAGEMENT TOU, V8, P476
  • [4] Analysis of some renewable energy uses and demand side measures for hotels on small Mediterranean islands: A case study
    Beccali, M.
    Finocchiaro, P.
    Ippolito, M. G.
    Leone, G.
    Panno, D.
    Zizzo, G.
    [J]. ENERGY, 2018, 157 : 106 - 114
  • [5] Modeling energy consumption and efficiency measures in the Italian hotel sector
    Bianco, Vincenzo
    Righi, Daniele
    Scarpa, Federico
    Tagliafico, Luca A.
    [J]. ENERGY AND BUILDINGS, 2017, 149 : 329 - 338
  • [6] Twenty-five years of sustainable tourism and the Journal of Sustainable Tourism: looking back and moving forward
    Bramwell, Bill
    Higham, James
    Lane, Bernard
    Miller, Graham
    [J]. JOURNAL OF SUSTAINABLE TOURISM, 2017, 25 (01) : 1 - 9
  • [7] International Diffusion of ISO 14000 Certification
    Corbett, CJ
    Kirsch, DA
    [J]. PRODUCTION AND OPERATIONS MANAGEMENT, 2001, 10 (03) : 327 - 342
  • [8] A study of energy performance of hotel buildings in Hong Kong
    Deng, SM
    Burnett, J
    [J]. ENERGY AND BUILDINGS, 2000, 31 (01) : 7 - 12
  • [9] Dynamic evaluation of the levelized cost of wind power generation
    Diaz, Guzman
    Gomez-Aleixandre, Javier
    Coto, Jose
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 101 : 721 - 729
  • [10] Application of COEMD-S-SVR model in tourism demand forecasting and economic behavior analysis: The case of Sanya City
    Fan, Guo-Feng
    Jin, Xiang-Ru
    Hong, Wei-Chiang
    [J]. JOURNAL OF THE OPERATIONAL RESEARCH SOCIETY, 2022, 73 (07) : 1474 - 1486