Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review

被引:9
|
作者
Chen, Jiaxin [1 ]
Zhao, Shuhua [1 ]
Zhu, Qianqian [1 ]
机构
[1] Sun Yat Sen Univ, Dept Anesthesiol, Affiliated Hosp 7, 628 Zhenyuan Rd, Shenzhen 518107, Guangdong, Peoples R China
关键词
SVV; PPV; Laparoscopic surgery; POSTOPERATIVE PULMONARY COMPLICATIONS; MECHANICALLY VENTILATED PATIENTS; CONTOUR METHODS IMPACT; GOAL-DIRECTED THERAPY; PNEUMOPERITONEUM; VARIABLES; METAANALYSIS; MANAGEMENT;
D O I
10.1007/s10877-022-00939-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The reliability of stroke volume variation (SVV) and pulse pressure variation (PPV) in predicting fluid responsiveness during laparoscopic surgery remains unclear. We conducted the present systematic review to summarize the current evidence. We reviewed studies that investigated the reliability of SVV and PPV in laparoscopic surgery. Seven studies were included in the final analysis. Two studies demonstrated that the area under the receiver operating characteristic curve (AUROC) for SVV was less than 0.8, and five studies reported that the AUROC was > 0.8. The pooled AUROC for SVV and PPV was more than 0.8 with high heterogeneities between the included studies. Most individual studies have suggested that SVV and PPV are sufficiently reliable for predicting fluid responsiveness during laparoscopic surgery. However, the limited number of patients, varied apparatus used to define fluid responsiveness, diverse definitions of fluid responsiveness, and different fluids used to perform fluid challenges in the included studies render firm conclusions about SVV's and PPV's reliability impossible.
引用
收藏
页码:379 / 387
页数:9
相关论文
共 50 条
  • [21] Respiratory induced dynamic variations of stroke volume and its surrogates as predictors of fluid responsiveness: applicability in the early stages of specific critical states
    Benes, Jan
    Zatloukal, Jan
    Kletecka, Jakub
    Simanova, Alena
    Haidingerova, Lenka
    Pradl, Richard
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2014, 28 (03) : 225 - 231
  • [22] Inferior vena cava diameter variation compared with pulse pressure variation as predictors of fluid responsiveness in patients with sepsis
    Theerawit, Pongdhep
    Morasert, Thotsaporn
    Sutherasan, Yuda
    JOURNAL OF CRITICAL CARE, 2016, 36 : 246 - 251
  • [23] Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring
    Rob Phillips
    Joe Brierley
    Journal of Clinical Monitoring and Computing, 2015, 29 : 197 - 200
  • [24] Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring
    Phillips, Rob
    Brierley, Joe
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 197 - 200
  • [25] Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively
    Lahner, D.
    Kabon, B.
    Marschalek, C.
    Chiari, A.
    Pestel, G.
    Kaider, A.
    Fleischmann, E.
    Hetz, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (03) : 346 - 351
  • [26] How Accurate Is Pulse Pressure Variation as a Predictor of Fluid Responsiveness?
    Verniquet, Andrew
    Kakel, Rafid
    ANESTHESIOLOGY, 2012, 116 (03) : 740 - 740
  • [27] Comparative study of pressure- and volume-controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients undergoing major abdominal surgery
    Lee, Ji Yeon
    Park, Hee Yeon
    Jung, Wol Seon
    Jo, Youn Yi
    Kwak, Hyun Jeong
    JOURNAL OF CRITICAL CARE, 2012, 27 (05) : 531.e9 - 531.e14
  • [28] Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness
    Mallat, J.
    Meddour, M.
    Durville, E.
    Lemyze, M.
    Pepy, F.
    Temime, J.
    Vangrunderbeeck, N.
    Tronchon, L.
    Thevenin, D.
    Tavernier, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 449 - 456
  • [29] Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery
    Guinot, P. -G.
    de Broca, B.
    Abou Arab, O.
    Diouf, M.
    Badoux, L.
    Bernard, E.
    Lorne, E.
    Dupont, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (01) : 28 - 33
  • [30] The Use of Pulse Pressure Variation and Stroke Volume Variation in Spontaneously Breathing Patients to Assess Dynamic Arterial Elastance and to Predict Arterial Pressure Response to Fluid Administration
    Cecconi, Maurizio
    Monge Garcia, M. Ignacio
    Gracia Romero, Manuel
    Mellinghoff, Johannes
    Caliandro, Francesca
    Grounds, Robert Michael
    Rhodes, Andrew
    ANESTHESIA AND ANALGESIA, 2015, 120 (01) : 76 - 84