Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review

被引:9
|
作者
Chen, Jiaxin [1 ]
Zhao, Shuhua [1 ]
Zhu, Qianqian [1 ]
机构
[1] Sun Yat Sen Univ, Dept Anesthesiol, Affiliated Hosp 7, 628 Zhenyuan Rd, Shenzhen 518107, Guangdong, Peoples R China
关键词
SVV; PPV; Laparoscopic surgery; POSTOPERATIVE PULMONARY COMPLICATIONS; MECHANICALLY VENTILATED PATIENTS; CONTOUR METHODS IMPACT; GOAL-DIRECTED THERAPY; PNEUMOPERITONEUM; VARIABLES; METAANALYSIS; MANAGEMENT;
D O I
10.1007/s10877-022-00939-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The reliability of stroke volume variation (SVV) and pulse pressure variation (PPV) in predicting fluid responsiveness during laparoscopic surgery remains unclear. We conducted the present systematic review to summarize the current evidence. We reviewed studies that investigated the reliability of SVV and PPV in laparoscopic surgery. Seven studies were included in the final analysis. Two studies demonstrated that the area under the receiver operating characteristic curve (AUROC) for SVV was less than 0.8, and five studies reported that the AUROC was > 0.8. The pooled AUROC for SVV and PPV was more than 0.8 with high heterogeneities between the included studies. Most individual studies have suggested that SVV and PPV are sufficiently reliable for predicting fluid responsiveness during laparoscopic surgery. However, the limited number of patients, varied apparatus used to define fluid responsiveness, diverse definitions of fluid responsiveness, and different fluids used to perform fluid challenges in the included studies render firm conclusions about SVV's and PPV's reliability impossible.
引用
收藏
页码:379 / 387
页数:9
相关论文
共 50 条
  • [1] Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review
    Jiaxin Chen
    Shuhua Zhao
    Qianqian Zhu
    Journal of Clinical Monitoring and Computing, 2023, 37 : 379 - 387
  • [2] A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery
    Piccioni, Federico
    Bernasconi, Filippo
    Tramontano, Giulia T. A.
    Langer, Martin
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (04) : 677 - 684
  • [3] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Zlicar, Marko
    Novak-Jankovic, Vesna
    Blagus, Rok
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 825 - 832
  • [4] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Messina, Antonio
    Caporale, Mariagiovanna
    Calabro, Lorenzo
    Lionetti, Giulia
    Bono, Daniele
    Matronola, Guia Margherita
    Brunati, Andrea
    Frassanito, Luciano
    Morenghi, Emanuela
    Antonelli, Massimo
    Chew, Michelle S.
    Cecconi, Maurizio
    CRITICAL CARE, 2023, 27 (01)
  • [5] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Marko Zlicar
    Vesna Novak-Jankovic
    Rok Blagus
    Maurizio Cecconi
    Journal of Clinical Monitoring and Computing, 2018, 32 : 825 - 832
  • [6] Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis
    Zhang, Zhongheng
    Lu, Baolong
    Sheng, Xiaoyan
    Jin, Ni
    JOURNAL OF ANESTHESIA, 2011, 25 (06) : 904 - 916
  • [7] Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease
    Kim, So Yeon
    Song, Young
    Shim, Jae Kwang
    Kwak, Young Lan
    JOURNAL OF CRITICAL CARE, 2013, 28 (03) : 318.e1 - 318.e7
  • [8] Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
    Alvarado Sanchez, Jorge Ivan
    Caicedo Ruiz, Juan Daniel
    Diaztagle Fernandez, Juan Jose
    Adolfo Ospina-Tascon, Gustavo
    Cruz Martinez, Luis Eduardo
    CLINICAL MEDICINE INSIGHTS-CIRCULATORY RESPIRATORY AND PULMONARY MEDICINE, 2020, 14
  • [9] Noninvasive pulse pressure variation and stroke volume variation to predict fluid responsiveness at multiple thresholds: a prospective observational study
    Vos, Jaap Jan
    Poterman, Marieke
    Salm, Pieternel Papineau
    Van Amsterdam, Kai
    Struys, Michel M. R. F.
    Scheeren, Thomas W. L.
    Kalmar, Alain F.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (11): : 1153 - 1160
  • [10] Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis
    Zhongheng Zhang
    Baolong Lu
    Xiaoyan Sheng
    Ni Jin
    Journal of Anesthesia, 2011, 25 : 904 - 916