Development and Validation of a Mixed-Reality Simulator for Reducing Biopsy Core Deviation During Simulated Freehand Systematic Prostate Biopsy

被引:0
作者
Lampotang, Samsun [1 ,2 ,3 ,4 ,9 ]
Lizdas, David E. [1 ,3 ]
Johnson, William T. [1 ,3 ]
Mei, Vincent [1 ,3 ]
Wakim, Jonathan [1 ,3 ]
Lou, XiangYang [6 ]
DeStephens, Anthony [1 ,2 ,3 ]
Acar, Yahya [1 ,3 ,7 ]
Moy, Louis [1 ,3 ,5 ]
Ahmad, Ardalanejaz [8 ]
Brisbane, Wayne [1 ,3 ,5 ]
Stringer, Thomas [1 ,3 ,5 ]
机构
[1] Univ Florida, Coll Med, Ctr Safety, Simulat & Adv Learning Technol, Gainesville, FL USA
[2] Univ Florida, Coll Med, Off Educ Affairs, Off Med Educ, Gainesville, FL USA
[3] Univ Florida, Coll Med, Dept Anesthesiol, Gainesville, FL USA
[4] Univ Florida, Clin & Translat Sci Inst, Coll Med, Gainesville, FL USA
[5] Univ Florida, Coll Med, Dept Urol, Gainesville, FL USA
[6] Univ Florida, Coll Publ Hlth & Hlth Profess, Dept Biostat, Gainesville, FL USA
[7] Univ Hlth Sci, Gulhane Sch Med, Dept Emergency Med, Ankara, Turkiye
[8] Univ Toronto, Dept Surg, Div Urol, Toronto, ON, Canada
[9] Univ Florida, Dept Anesthesiol, Coll Med, 1600 SW Archer Rd,POB 100254, Gainesville, FL 32610 USA
来源
SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE | 2024年 / 19卷 / 02期
关键词
Prostatic neoplasms; biopsy; large-core needle; image-guided biopsy; computer simulation; virtual reality; educational; NEEDLE-BIOPSY; CANCER; ACCURACY;
D O I
10.1097/SIH.0000000000000723
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Introduction: We describe the development and validation of a mixed-reality prostate biopsy (PBx) simulator with built-in guidance aids and real-time 3-dimensional visualization. Methods: We evaluated our simulator during one-on-one training sessions with urology residents and attendings from 2018 to 2022. Participants performed freehand, side-fire, double-sextant transrectal ultrasound-guided systematic prostate biopsy (sPBx). After a baseline assessment (first set of 12 biopsy cores), participants trained for 25 minutes with visualization and cognitive aids activated. Training was followed by an exit set of 12 biopsy cores without visualization or cognitive aids and afterward, subjective assessment by trainees of the simulator. Deviation is the shortest distance of the center of a core from its intended template location. Results: Baseline deviations (mean +/- SD) for residents (n = 24) and attendings (n = 4) were 13.4 +/- 8.9 mm and 8.5 +/- 3.6 mm (P < 0.001), respectively. Posttraining deviations were 8.7 +/- 6.6 mm and 7.6 +/- 3.7 mm (P = 0.271), respectively. Deviations between baseline and exit were decreased significantly for residents (P < 0.001) but not for attendings (P = 0.093). Overall feedback from participants was positive. Confidence in performing a PBx increased in novices after training (P = 0.011) and did not change among attendings (P = 0.180). Conclusions: A new PBx simulator can quantify and improve accuracy during simulated freehand sPBx while providing visualization and graphical feedback. Improved simulated sPBx accuracy could lead to more even distribution of biopsy cores within the prostate when performed in clinical settings, possibly reducing the high risk of missing an existing lesion and thus decreasing the time to initiating treatment, if indicated.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 15 条
  • [1] Avni S., 2010, Proc SPIE Int Soc Opt Eng, V7625, p76251A
  • [2] Chalasani V, 2011, CUAJ-CAN UROL ASSOC, V5, P19, DOI 10.5489/cuaj.09159
  • [3] Assessment of Time-to-Treatment Initiation and Survival in a Cohort of Patients With Common Cancers
    Cone, Eugene B.
    Marchese, Maya
    Paciotti, Marco
    Nguyen, David-Dan
    Nabi, Junaid
    Cole, Alexander P.
    Molina, George
    Molina, Rose L.
    Minami, Christina A.
    Mucci, Lorelei A.
    Kibel, Adam S.
    Trinh, Quoc-Dien
    [J]. JAMA NETWORK OPEN, 2020, 3 (12) : E2030072
  • [4] Repeat Prostate Biopsy Accuracy: Simulator-based Comparison of Two- and Three-dimensional Transrectal US Modalities
    Cool, Derek W.
    Connolly, Michael J.
    Sherebrin, Shi
    Eagleson, Roy
    Izawa, Jonathan I.
    Amann, Justin
    Romagnoli, Cesare
    Romano, Walter M.
    Fenster, Aaron
    [J]. RADIOLOGY, 2010, 254 (02) : 587 - 594
  • [5] Simulation-based training for prostate biopsies: towards the validation of the Biopsym simulator
    Fiard, Gaelle
    Selmi, Sonia-Yuki
    Promayon, Emmanuel
    Descotes, Jean-Luc
    Troccaz, Jocelyne
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2020, 29 (06) : 359 - 365
  • [6] Initial Validation of a Virtual-Reality Learning Environment for Prostate Biopsies: Realism Matters!
    Fiard, Gaelle
    Selmi, Sonia-Yuki
    Promayon, Emmanuel
    Vadcard, Lucile
    Descotes, Jean-Luc
    Troccaz, Jocelyne
    [J]. JOURNAL OF ENDOUROLOGY, 2014, 28 (04) : 453 - 458
  • [7] Geometric Evaluation of Systematic Transrectal Ultrasound Guided Prostate Biopsy
    Han, Misop
    Chang, Doyoung
    Kim, Chunwoo
    Lee, Brian J.
    Zuo, Yihe
    Kim, Hyung-Joo
    Petrisor, Doru
    Trock, Bruce
    Partin, Alan W.
    Rodriguez, Ronald
    Carter, H. Ballentine
    Allaf, Mohamad
    Kim, Jongwon
    Stoianovici, Dan
    [J]. JOURNAL OF UROLOGY, 2012, 188 (06) : 2404 - 2409
  • [8] Can transrectal needle biopsy be optimised to detect nearly all prostate cancer with a volume of ≥0.5 mL? A three-dimensional analysis
    Kanao, Kent
    Eastham, James A.
    Scardino, Peter T.
    Reuter, Victor E.
    Fine, Samson W.
    [J]. BJU INTERNATIONAL, 2013, 112 (07) : 898 - 904
  • [9] Lampotang S., 2020, Comprehensive Healthcare Simulation: Anesthesiology, P325
  • [10] SMMARTS An Open Architecture Development Platform for Modular, Mixed, and Augmented Reality Procedural and Interventional Simulators
    Lampotang, Samsun
    Bigos, Andre K.
    Avari, Kaizad
    Johnson, William T.
    Mei, Vincent
    Lizdas, David E.
    [J]. SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2021, 16 (05): : 353 - 361