Improving regional medical laboratory center report quality through a report recall management system

被引:1
作者
Zhang, Chuang [2 ]
Ji, Xiang [3 ]
Wei, Jiehong [3 ]
Dou, Xiaowen [3 ]
Chen, Dayang [1 ]
Zhang, Xiuming [1 ]
机构
[1] Shenzhen Univ, Affiliated Hosp 3, Med Lab, 33 Zhongyuan Rd,Buji St, Shenzhen 518000, Peoples R China
[2] Anhui Univ Sci & Technol, Sch Med, Huainan, Peoples R China
[3] Shenzhen Univ, Affiliated Hosp 3, Med Lab, Shenzhen, Peoples R China
关键词
laboratory report; recall; intelligent management; continuous improvement; EXTRA-ANALYTICAL PHASES; SPECIFICATIONS; INDICATORS;
D O I
10.1515/cclm-2023-0786
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Currently, most medical laboratories do not have a dedicated software for managing report recalls, and relying on traditional manual methods or laboratory information system (LIS) to record recall data is no longer sufficient to meet the quality management requirements in the large regional laboratory center. The purpose of this article was to describe the research process and preliminary evaluation results of integrating the Medical Laboratory Electronic Record System (electronic record system) laboratory report recall function into the iLab intelligent management system for quality indicators (iLab system), and to introduce the workflow and methods of laboratory report recall management in our laboratory.Methods: This study employed cluster analysis to extract commonly used recall reasons from laboratory report recall records in the electronic record system. The identified recall reasons were validated for their applicability through a survey questionnaire and then incorporated into the LIS for selecting recall reasons during report recall. The statistical functionality of the iLab system was utilized to investigate the proportion of reports using the selected recall reasons among the total number of reports, and to perform visual analysis of the recall data. Additionally, we employed P-Chart to establish quality targets and developed a "continuous improvement process" electronic flow form.Results: The reasons for the recall of laboratory reports recorded in the electronic recording system were analyzed. After considering the opinions of medical laboratory personnel, a total of 12 recall reasons were identified, covering 73.05 % (1854/2538) of the recalled laboratory reports. After removing data of mass spectra lab with significant anomalies, the coverage rate increased to 82.66 % (1849/2237). The iLab system can generate six types of statistical graphs based on user needs, including statistical time, specialty labs (or divisions), test items, reviewers, reasons for report recalls, and distribution of the recall frequency of 0-24 h reports. The control upper limit of the recall rate of P-Chart based on laboratory reports can provide quality targets suitable for each professional group at the current stage. Setting the five stages of continuous process improvement reasonably and rigorously can effectively achieve the goal of quality enhancement.Conclusions: The enhanced iLab system enhances the intelligence and sustainable improvement capability of the recall management of laboratory reports, thus improving the efficiency of the recall management process and reducing the workload of laboratory personnel.
引用
收藏
页码:341 / 352
页数:12
相关论文
共 22 条
  • [1] [Anonymous], 2022, quality and developmental competence J.Front
  • [2] [Anonymous], 2018, ISO (2018a) ISO 19011:2018 Guidelines for auditing management systems
  • [3] Terminology, units and reporting - how harmonized do we need to be?
    Flatman, Robert
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (01) : 1 - 11
  • [4] Challenges and Opportunities in Implementing Total Laboratory Automation
    Genzen, Jonathan R.
    Burnham, Carey-Ann D.
    Felder, Robin A.
    Hawker, Charles D.
    Lippi, Giuseppe
    Palmer, Octavia M. Peck
    [J]. CLINICAL CHEMISTRY, 2018, 64 (02) : 259 - 264
  • [5] Report formatting in laboratory medicine - a call for harmony
    Jones, Graham R. D.
    Legg, Michael
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (01) : 61 - 65
  • [6] Safe reading of chemical pathology reports: the RCPAQAP Report Assessment Survey
    Koetsier, Sabrina
    Jones, Graham Ross Dallas
    Badrick, Tony
    [J]. PATHOLOGY, 2016, 48 (04) : 357 - 362
  • [7] THE USE OF CONTROL CHARTS IN THE CLINICAL LABORATORY
    LEVEY, S
    JENNINGS, ER
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1950, 20 (11) : 1059 - 1066
  • [8] A Six-Sigma approach for comparing diagnostic errors in healthcare-where does laboratory medicine stand?
    Lippi, Giuseppe
    Plebani, Mario
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (10)
  • [9] Liu W, 2021, INTERNET J LAB MED, V42, P1271
  • [10] Medical error-the third leading cause of death in the US
    Makary, Martin A.
    Daniel, Michael