Influence of Surface Treatment and Accelerated Ageing on Biaxial Flexural Strength and Hardness of Zirconia

被引:3
作者
Rohr, Nadja [1 ]
Schonenberger, Angela Jacqueline [1 ]
Fischer, Jens [1 ]
机构
[1] Univ Basel, Univ Ctr Dent Med Basel UZB, Dept Reconstruct Dent, Biomat & Technol, CH-4058 Basel, Switzerland
关键词
zirconia implants; accelerated ageing; surface treatment; mechanical properties; OSTEOBLAST-LIKE CELLS; Y-TZP; MARTENS HARDNESS; TITANIUM; IMPLANTS; ROUGHNESS; CERAMICS;
D O I
10.3390/ma16030910
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim was to investigate how the surface treatment and the process of accelerated ageing of zirconia for dental implants affect the biaxial flexural strength and hardness. Zirconia discs with a diameter of 12.6 mm were subjected to either one of the following treatments: polishing (Zp); polishing and heat treatment at 1250 degrees C for 1 h (Zpt); machining (Zm); machining and heat treatment (Zmt); or sandblasting, acid-etching, and heat treatment (Z14) (n = 45 per group). Biaxial flexural strength and Martens hardness (HM) were measured without further treatment and after accelerated ageing for 5 h or 5 x 5 h according to ISO 13356 (n = 15 per group). Two-way ANOVA was applied to test the effect of surface treatment and ageing (alpha = 0.05). The reliability of the specimens was described with Weibull two-parameter distribution of biaxial flexural strength data. Overall, the surface treatment (p < 0.001) and ageing (p = 0.012) revealed a significant effect on biaxial flexural strength values, while HM was only affected by the surface treatment (p < 0.001) but not ageing (p = 0.160). Surface treatment significantly affected HM (p < 0.001) but not ageing (p = 0.160). The applied surface treatments affected the biaxial flexural strength and HM of zirconia. For accelerated ageing, a duration of both 5 h and 5 x 5 h is recommended to evaluate the effect of surface treatments. Zm was the most reliable surface as it was least affected by ageing and provided low standard deviations of biaxial flexural strength values.
引用
收藏
页数:11
相关论文
共 31 条
[21]   The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic [J].
Kosmac, T ;
Oblak, C ;
Jevnikar, P ;
Funduk, N ;
Marion, L .
DENTAL MATERIALS, 1999, 15 (06) :426-433
[22]   Ceramic implants (Y-TZP): are they a viable alternative to titanium implants for the support of overdentures? A randomized clinical trial [J].
Osman, Reham B. ;
Swain, Michael V. ;
Atieh, Momen ;
Ma, Sunyoung ;
Duncan, Warwick .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (12) :1366-1377
[23]   In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics [J].
Papanagiotou, Harry P. ;
Morgano, Steven M. ;
Giordano, Russell A. ;
Pober, Richard .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (03) :154-164
[24]   Zirconia as a ceramic biomaterial [J].
Piconi, C ;
Maccauro, G .
BIOMATERIALS, 1999, 20 (01) :1-25
[25]   Crystal structure of zirconia affects osteoblast behavior [J].
Rohr, Nadja ;
Bergemann, Claudia ;
Nebe, J. Barbara ;
Fischer, Jens .
DENTAL MATERIALS, 2020, 36 (07) :905-913
[26]   Surface structuring of zirconia to increase fibroblast viability [J].
Rohr, Nadja ;
Zeller, Barbara ;
Matthisson, Lea ;
Fischer, Jens .
DENTAL MATERIALS, 2020, 36 (06) :779-786
[27]   Chewing simulation of zirconia implant supported restorations [J].
Rohr, Nadja ;
Balmer, Marc ;
Mueller, Johannes A. ;
Maertin, Sabrina ;
Fischer, Jens .
JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (03) :361-367
[28]   Implant surface roughness affects osteoblast gene expression [J].
Schneider, GB ;
Perinpanayagam, H ;
Clegg, M ;
Zaharias, R ;
Seabold, D ;
Keller, J ;
Stanford, C .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (05) :372-376
[29]   Is zirconia a viable alternative to titanium for oral implant? A critical review [J].
Sivaraman, Karthik ;
Chopra, Aditi ;
Narayan, Aparna I. ;
Balakrishnan, Dhanasekar .
JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) :121-133
[30]   A histomorphometric evaluation of screw-shaped implants each prepared with two surface roughnesses [J].
Wennerberg, A ;
Hallgren, C ;
Johansson, C ;
Danelli, S .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (01) :11-19