Magnetic Graphene Oxide Modified with a Surface-Active Ionic Liquid for Ultrasound-Assisted Solid-Phase Extraction (UA-SPE) to Preconcentrate Lenalidomide from Human Plasma with Determination by High-Performance Liquid Chromatography with Ultraviolet Detection (HPLC-UV)

被引:0
|
作者
Movahedi, Farnaz [1 ]
Ezoddin, Maryam [2 ]
Adlnasab, Laleh [3 ]
Shojaei, Rouhallah [2 ]
机构
[1] Stand Res Inst, Chem & Petrochem Res Ctr, Cellulos Mat & Packaging Res Grp, Karaj, Iran
[2] Payame Noor Univ PNU, Dept Chem, Tehran, Iran
[3] Stand Res Inst, Chem & Petrochem Res Ctr, Chem Res Grp, POB 3174-139, Karaj, Iran
关键词
High-performance liquid chromatography with ultraviolet detection (HPLC-UV); lenalidomide; magnetic graphene oxide; surface-active ionic liquid; ultrasound-assisted solid-phase extraction (UA-SPE); SELF-AGGREGATION; METHYLENE-BLUE; REMOVAL; DEXAMETHASONE; NANOPARTICLES; BEHAVIOR; ADSORPTION; SILICA;
D O I
10.1080/00032719.2022.2140434
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new magnetic graphene oxide (MGO) composite was developed as an adsorbent for the preconcentration of lenalidomide (LND) by ultrasound-assisted solid-phase extraction (UA-SPE) prior to determination by high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The adsorbent was fabricated through chemical functionalization of a new surface-active ionic liquid (SAIL), i.e. 1-methyl-3-(trimethoxysilyl propyl)-imidazolium dodecyl sulfate (TMES-Im-DS) on MGO. The synthesized material presented the benefits of excellent adsorption for LND. The characterization of the synthesized functionalized magnetic nanocomposite was performed by Fourier transform-infrared spectroscopy, field emission scanning electron microscopy, Brunauer-Emmett-Teller (BET), vibrating sample magnetometry, and energy-dispersive X-ray spectroscopy. After optimization of the parameters, the limits of detection (LOD) and limit of quantification (LOQ) were 0.2 and 0.8 mu g L-1 and 0.6 and 2.5 mu g L(-1)in water and plasma samples, respectively. The enrichment factors (EFs) were from 90 to 180 in the samples. The relative standard deviation (RSD%, n = 5) as intra- and inter-day precision were from 6.3% to 7.5% and 7.1% to 8.5% in water and plasma, respectively. Lastly, the developed method presented good results for the preconcentration of LND in plasma with satisfactory repeatability.
引用
收藏
页码:1685 / 1700
页数:16
相关论文
共 50 条
  • [1] Reduced Graphene Oxide Nanoribbons for the Magnetic Solid-Phase Extraction (MSPE) of Bisphenol Endocrine Disruptors in Carbonated Beverages with Determination by High-Performance Liquid Chromatography with Ultraviolet Detection (HPLC-UV)
    Ding, Ya-Wen
    Feng, Shi-Lan
    Chen, Juan
    ANALYTICAL LETTERS, 2021, 54 (14) : 2259 - 2275
  • [2] Determination of hyperforin in human plasma using solid-phase extraction and high-performance liquid chromatography with ultraviolet detection
    Cui, YY
    Gurley, B
    Ang, CYW
    Leakey, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (01): : 129 - 135
  • [3] Determination of rutin in human plasma by high-performance liquid chromatography utilizing solid-phase extraction and ultraviolet detection
    Ishii, K
    Furuta, T
    Kasuya, Y
    JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (01): : 161 - 168
  • [4] DETERMINATION OF LOMEFLOXACIN IN HUMAN PLASMA BY SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH UV DETECTION
    CARLUCCI, G
    CILLI, A
    LIBERATO, M
    MAZZEO, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) : 1105 - 1108
  • [5] Determination of clenbuterol in porcine tissues using solid-phase extraction combined with ultrasound-assisted dispersive liquid-liquid microextraction and HPLC-UV detection
    Liu, Baomi
    Yan, Hongyuan
    Qiao, Fengxia
    Geng, Yuru
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (01): : 90 - 94
  • [6] Determination of Pyrethroids in Paris polyphylla Sample by High-Performance Liquid Chromatography Using Ultrasound-Assisted Magnetic Solid-Phase Extraction
    Zhang, Wei
    Zhao, Xin
    Meng, Hengling
    Yang, Jin
    Wei, Xiang
    Min, Yong
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [7] Determination of apovincaminic acid in human plasma by high-performance liquid chromatography using solid-phase extraction and ultraviolet detection
    Chen, J
    Cai, J
    Tao, WX
    Mei, N
    Cao, SL
    Jiang, XG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 201 - 206
  • [8] DETERMINATION OF TENOXICAM IN HUMAN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    CARLUCCI, G
    MAZZEO, P
    PALUMBO, G
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (04): : 683 - 695
  • [9] Determination of melatonin in human plasma with solid-phase extraction, high-performance liquid chromatography and fluorescence detection
    Römsing, S
    Ulfberg, J
    Bergqvist, Y
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2003, 63 (01): : 81 - 88
  • [10] Determination of ketorolac in human plasma by reversed-phase high-performance liquid chromatography using solid-phase extraction and ultraviolet detection
    Wang, Z
    Dsida, RM
    Avram, MJ
    JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 383 - 386