A deep-learning method using single phantom to enhance megavoltage image quality for patient positioning in chest radiotherapy: a feasibility study

被引:0
作者
Jeon, Hosang [1 ,2 ]
Kim, Dong Woon [1 ,2 ]
Joo, Ji Hyeon [1 ,2 ,3 ]
Ki, Yongkan [1 ,2 ,3 ]
Kim, Wontaek [3 ,4 ]
Park, Dahl [4 ]
Nam, Jiho [4 ]
Kim, Dong Hyeon [3 ,4 ]
机构
[1] Pusan Natl Univ, Dept Radiat Oncol, Yangsan Hosp, Yangsan, South Korea
[2] Pusan Natl Univ, Res Inst Convergence Biomed Sci & Technol, Yangsan Hosp, Yangsan, South Korea
[3] Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
[4] Pusan Natl Univ Hosp, Dept Radiat Oncol, Pusan, South Korea
基金
新加坡国家研究基金会;
关键词
Deep learning; Megavoltage image; Kilovoltage image; Radiotherapy; Patient setup;
D O I
10.1007/s40042-023-00852-4
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Image-guided radiation treatment (IGRT) is essential for verifying patient positioning during modern radiotherapy. Although megavoltage digital radiographs (MV-DR) are available on most therapeutic linear accelerators and can be used for checking treatment beam shapes, they are much inferior to kilovoltage digital radiographs (KV-DR) in terms of image quality. As it is generally challenging to obtain a well-aligned MV - KV training dataset of patients in clinical scenarios, there is a lack of sufficient information on the accuracy of KV-DR synthesized using supervised training. Therefore, we aimed to synthesize pseudo KV-DR (pKV-DR) from MV-DR using a training dataset developed with a single anthropomorphic chest phantom. The phantom was adopted to obtain MV - KV image pairs at various gantry angles because these image pairs of patients are highly difficult to acquire and exactly align with each other. A deep-learning model based on U-net architecture was trained with the phantom image pairs using the mean absolute error (MAE) and structure similarity (SSIM) indices as loss functions. The mean MAEs of MV-DR and pKV-DR against KV-DR as the ground truth were 0.1152 and 0.0169, respectively, and their mean SSIM values were 0.9693 and 0.9942, respectively. Finally, pKV-DR showed a relatively high image similarity to that of KV-DR with smaller MAE (14.7%) and higher SSIM (2.5%), compared with MV-DR. The image contrast was also improved by 37.1% in clinical cases. The proposed method is expected to enable the implementation of improved IGRT with high image quality of KV-DR level, even in clinics where MV-DR is only available.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 17 条
  • [1] Alemi A. A., 2017, P 2017 INT C LEARNIN
  • [2] Radiation oncology in the era of precision medicine
    Baumann, Michael
    Krause, Mechthild
    Overgaard, Jens
    Debus, Juergen
    Bentzen, Soren M.
    Daartz, Juliane
    Richter, Christian
    Zips, Daniel
    Bortfeld, Thomas
    [J]. NATURE REVIEWS CANCER, 2016, 16 (04) : 234 - 249
  • [3] A deep-learning method for generating synthetic kV-CT and improving tumor segmentation for helical tomotherapy of nasopharyngeal carcinoma
    Chen, Xinyuan
    Yang, Bining
    Li, Jingwen
    Zhu, Ji
    Ma, Xiangyu
    Chen, Deqi
    Hu, Zhihui
    Men, Kuo
    Dai, Jianrong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (22)
  • [4] Goodfellow, 2014, P 2014 NEURAL INFORM
  • [5] Kingma D.P, 2014, PREPRINT
  • [6] Medical Imaging using Machine Learning and Deep Learning Algorithms: A Review
    Latif, Jahanzaib
    Xiao, Chuangbai
    Imran, Azhar
    Tu, Shanshan
    [J]. 2019 2ND INTERNATIONAL CONFERENCE ON COMPUTING, MATHEMATICS AND ENGINEERING TECHNOLOGIES (ICOMET), 2019,
  • [7] Improvement of megavoltage computed tomography image quality for adaptive helical tomotherapy using cycleGAN-based image synthesis with small datasets
    Lee, Dongyeon
    Jeong, Sang Woon
    Kim, Sung Jin
    Cho, Hyosung
    Park, Won
    Han, Youngyih
    [J]. MEDICAL PHYSICS, 2021, 48 (10) : 5593 - 5610
  • [8] A modality conversion approach to MV-DRs and KV-DRRs registration using information bottlenecked conditional generative adversarial network
    Liu, Cong
    Lu, Zheming
    Ma, Longhua
    Wang, Lang
    Jin, Xiance
    Si, Wen
    [J]. MEDICAL PHYSICS, 2019, 46 (10) : 4575 - 4587
  • [9] Synthesising KV-DRRs from MV-DRs with fractal hourglass convolutional network
    Liu, Cong
    Huang, Miao
    Ma, Longhua
    Lu, Zheming
    [J]. ELECTRONICS LETTERS, 2018, 54 (12) : 762 - 763
  • [10] A Megavoltage CT Image Enhancement Method for Image-Guided and Adaptive Helical TomoTherapy
    Liu, Yaru
    Yue, Chenxi
    Zhu, Jian
    Yu, Haining
    Cheng, Yang
    Yin, Yong
    Li, Baosheng
    Dong, Jiwen
    [J]. FRONTIERS IN ONCOLOGY, 2019, 9